• Title/Summary/Keyword: Patient Safety Management

Search Result 444, Processing Time 0.023 seconds

Effects of ASPAN's Evidence-based Clinical Practice Guidelines for Promotion of Hypothermia of Patients with Total Knee Replacement Arthroplasty (슬관절 전치환술 환자의 저체온 관리를 위한 ASPAN의 근거기반 임상실무 가이드라인 적용 효과)

  • Yoo, Je Bog;Park, Hyun Ju;Chae, Ji Yeoun;Lee, Eun Ju;Shin, Yoo Jung;Ko, Justin Sangwook;Kim, Nam Cho
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.3
    • /
    • pp.352-360
    • /
    • 2013
  • Purpose: In this study an examination was done of the effects of the American Society of PeriAnesthesia Nurses (ASPAN) Evidence-Based Clinical Practice Guidelines on body temperature, shivering, thermal discomfort, and time to achieve normothermia in patients undergoing total knee replacement arthroplasty (TKRA) under spinal anesthesia. Methods: This study was an experimental study with a randomized controlled trial design. Participants (n=60) were patients who underwent TKRA between December 2011 and March 2012. Experimental group (n=30) received active and passive warming measures as described in the ASPAN's guidelines. Control group (n=30) received traditional care. Body temperature, shivering, thermal discomfort, time to achieve normothermia were measured in both groups at 30 minute intervals. Results: Experimental group had slightly higher body temperature compared to control group (p=.002). Thermal discomfort was higher in the experimental group before surgery but higher in the control group after surgery (p=.034). It decreased after surgery (p=.041) in both groups. Time to achieve normothermia was shorter in the experimental group (p=.010). Conclusion: ASPAN's guidelines provide guidance on measuring patient body temperature at regular intervals and on individualized and differentiated hypothermia management which can be very useful in nursing care, particularly in protecting patient safety and improving quality of nursing.

Surgical Treatment of Pancreatic Trauma in Children (소아의 외상성 췌장 손상의 수술적 치료)

  • Cho, Jae-Hyung;Kim, Hyun-Young;Jung, Sung-Eun;Park, Kwi-Won
    • Advances in pediatric surgery
    • /
    • v.19 no.2
    • /
    • pp.98-107
    • /
    • 2013
  • Debates exist about the appropriate treatment for pancreatic trauma in children. We intended to examine the safety of the operation of pancreatic trauma in children. This is a retrospective study of 13 patients, younger than 15, who underwent surgery for pancreatic trauma, between 1993 and 2011 in Seoul National University Children's Hospital. Medical records were reviewed for mechanism of trauma, clinical characteristics, radiological findings, operation and outcomes. Organ injury scaling from the AAST (American Association for Surgery of Trauma) was used. All injuries were caused by blunt trauma. Patients with grade III, IV, and those who were difficult to distinguish grade II from IV, underwent surgery due to severe peritonitis. Three patients with grade II were operated for reasons of mesenteric bleeding, tumor rupture of the pancreas, and progression of peritonitis. Distal pancreatectomy was performed in 10 patients and subtotal pancreatectomy and pylorus preserving pancreaticoduodenectomy in 1 patient each. The remaining one underwent surgical debridement because of severe adhesions. The location of injury, before and after operation, coincided in 83.3%. The degree of injury, before and after the operation, was identical in all the patients except for those who were difficult to tell apart grade II from grade IV, and those cannot be graded due to severe adhesion. Postoperative complications occurred in 23.1%, which improved with conservative treatment. Patients were discharged at mean postoperative 12(range 8~42) days. Even though patients with complications took longer in time from diagnosis to operation, time of trauma to operation and hospital stay, this difference was not significant. In conclusion, When pancreatic duct injury is present, or patient shows deterioration of clinical manifestation without evidence of definite duct injury, or trauma is accompanied by other organ injury or tumor rupture, operative management is advisable, and we believe it is a safe and feasible method of treatment.

The Development and Implementation of Ward Monitoring Service Using Bluetooth Low Energy Scanners for Infectious Disease Response (감염병 대응 비콘 스캐너 기반의 병실 모니터링 서비스 개발)

  • Lee, Kyu-Man;Park, Ju-young
    • Journal of Digital Convergence
    • /
    • v.15 no.3
    • /
    • pp.287-294
    • /
    • 2017
  • This study attempted to develop a beacon scanner based ward monitoring service in order to respond to the new paradigm of medical environment which is trying to introduce ICT technology as medical service to track and manage the spread path of large infectious diseases such as MERS. The study also included beacon hardware development, firmware development for the beacon low-power bluetooth 4.0, and server and web-based dashboard UI development. Using these, we have developed a customized monitoring system that provides functions such as locating patients by location based service and monitoring based on web UI. It is possible to maximize the efficiency of offline hospital services and to value active infection control and patient safety by integrating online technology into the area where online technologies such as beacons are not properly integrated.

A Survey of the Management of Patient Dose at Medical Center (의료기관의 환자 피폭선량 관리 실태조사)

  • Jeon, Go-Eun;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Medical radiation therapy using radioactive isotope I-131 is an extremely critical part of nuclear medicine. It is important to evaluate patients' radiation exposure dose for the safe handling of radiation in the medical area. Cautions related to patients' exposure to radiation are as follows. First, the dose should not exceed the level required for medical purpose. Second, unnecessary exposure should be avoided. Third, it should be considered carefully first whether the same medical purpose is attainable without the use of radiation. For these purposes, we need to evaluate patients' radiation exposure dose. Thus, in order to promote the safety of patients in medical wards, this study sampled air using an air sampler and measured the radioactivity of the sample using a gamma counter. According to the results of measuring I-131 in medical wards, the highest level, the average and the lowest level were $404.11Bq/m^3$, $228.27Bq/m^3$ and $126.17Bq/m^3$, respectively.

  • PDF

Surgical Resection of Cardiac Hemangiosarcoma Using Articulated Surgical Stapler in a Dog

  • Woo-Jin Kim;Kyung-Min Kim;Won-Jong Lee;Chang-Hwan Moon;Hae-Beom Lee;Seong-Mok Jeong;Dae-Hyun Kim
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.37-42
    • /
    • 2024
  • This case report discusses the successful surgical resection of cardiac hemangiosarcoma in a dog using an articulated surgical stapler. Cardiac tumors, particularly hemangiosarcomas, have a poor prognosis. Recommended treatment involves surgical removal of the primary tumor, along with chemotherapy. However, the use of staples for cardiac tumor resection has not yet been extensively documented in the veterinary literature. A 10-year-old dachshund with pericardial effusion underwent surgery to remove a right atrial mass. An articulated linear cutting stapler was used for tumor resection. The patient experienced chylothorax as a complication but recovered well. However, the patient later developed respiratory symptoms and died, most likely due to aspiration pneumonia. The surgical stapler provided stability, convenience, and a shorter surgical time during tumor resection. Surgical resection combined with chemotherapy improves the survival of dogs with cardiac hemangiosarcoma. The stability and adjustability of the stapling device make it advantageous for cardiac tumor resection. Although complications, such as chylothorax, can arise, appropriate management can lead to positive outcomes. This case report demonstrates the feasibility and safety of using an articulated surgical stapler for cardiac tumor resection in dogs. Insights from this case can guide future research and clinical practice.

Comparison of pain relief in soft tissue tumor excision: anesthetic injection using an automatic digital injector versus conventional injection

  • Hye Gwang Mun;Bo Min Moon;Yu Jin Kim
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.1
    • /
    • pp.17-21
    • /
    • 2024
  • Background: The pain caused by local anesthetic injection can lead to patient anxiety prior to surgery, potentially necessitating sedation or general anesthesia during the excision procedure. In this study, we aim to compare the pain relief efficacy and safety of using a digital automatic anesthetic injector for local anesthesia. Methods: Thirty-three patients undergoing excision of a benign soft tissue tumor under local anesthesia were prospectively enrolled from September 2021 to February 2022. A single-blind, randomized controlled study was conducted. Patients were divided into two groups by randomization: the experimental group with digital automatic anesthetic injector method (I-JECT group) and the control group with conventional injection method. Before surgery, the Amsterdam preoperative anxiety information scale was used to measure the patients' anxiety. After local anesthetic was administered, the Numeric Pain Rating Scale was used to measure the pain. The amount of anesthetic used was divided by the surface area of the lesion was recorded. Results: Seventeen were assigned to the conventional group and 16 to the I-JECT group. The mean Numeric Pain Rating Scale was 1.75 in the I-JECT group and 3.82 in conventional group. The injection pain was lower in the I-JECT group (p< 0.01). The mean Amsterdam preoperative anxiety information scale was 11.00 in the I-JECT group and 9.65 in conventional group. Patient's anxiety did not correlate to injection pain regardless of the method of injection (p= 0.47). The amount of local anesthetic used per 1 cm2 of tumor surface area was 0.74 mL/cm2 in the I-JECT group and 2.31 mL/cm2 in the conventional group. The normalization amount of local anesthetic was less in the I-JECT group (p< 0.01). There was no difference in the incidence of complications. Conclusion: The use of a digital automatic anesthetic injector has shown to reduce pain and the amount of local anesthetics without complication.

Transarterial Chemoembolization for Hepatocellular Carcinoma: 2023 Expert Consensus-Based Practical Recommendations of the Korean Liver Cancer Association

  • Yuri Cho;Jin Woo Choi;Hoon Kwon;Kun Yung Kim;Byung Chan Lee;Hee Ho Chu;Dong Hyeon Lee;Han Ah Lee;Gyoung Min Kim;Jung Suk Oh;Dongho Hyun;In Joon Lee;Hyunchul Rhim;Research Committee of the Korean Liver Cancer Association
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.606-625
    • /
    • 2023
  • Transarterial chemoembolization (TACE) was introduced in 1977 with the administration of chemotherapeutic agent to gelatin sponge particles through the hepatic artery in patients with hepatocellular carcinoma (HCC) and was established as conventional TACE using Lipiodol in the 1980s. In the 2000s, drug-eluting beads were developed and applied clinically. Currently, TACE is a commonly used non-surgical treatment modality for patients with HCC who are unsuitable for curative treatment. Considering the vital role of TACE in the management of HCC, it is crucial to organize current knowledge and expert opinions regarding patient preparation, procedural techniques, and post-treatment care in TACE, which can enhance therapeutic efficacy and safety. A group of 12 experts in the fields of interventional radiology and hepatology, convened by the Research Committee of the Korean Liver Cancer Association (KLCA), has developed expert consensus-based practical recommendations in TACE. These recommendations have been endorsed by the Korean Society of Interventional Radiology and provide useful information and direction in performing TACE procedure as well as pre- and post- procedural patient care.

Initial experience with Scepter Mini dual lumen balloon for embolization of cerebrovascular diseases

  • Muhammad U Manzoor;Ibrahim A. Almulhim;Abdullah A. Alrashed;Shorog Althubait;Abdulrahman Y. Alturki;Sultan M. Al-Qahtani
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.175-181
    • /
    • 2023
  • Objective: Endovascular treatment of cerebrovascular diseases is often challenging due to small caliber, tortuous distal vessels. Several devices and techniques have evolved to overcome these challenges. Recently, a low profile dual lumen microballoon catheter, specifically designed for distal navigation is employed for neurovascular procedures. Due to its recent advent, scarce data is available on clinical utility and safety of Scepter Mini. The aim of this case series is to report our initial experience with Scepter Mini in the management of various cerebrovascular diseases. Methods: All interventional neurovascular cases performed using Scepter Mini between January 2020 till April 2021 were included. Data regarding patient demographics, procedural details and complications was retrospectively collected from patient's electronic medical record and procedure reports. Results: Total twelve embolization procedures were performed in eleven patients, including six brain arteriovenous malformation, two dural arteriovenous fistula, one vein of Galen malformation and three hyper-vascular glomus tumor embolizations. All procedures were successfully performed with adequate penetration of the embolic agent. Complete embolization was performed in six procedures, while intended partial embolization was performed in the rest of procedures. Scepter Mini was solely used in ten procedures, however in the other two embolization procedures it was used as an additional conjunct tool to complete the intended embolization. No balloon related complication was observed in any procedure. Conclusions: Scepter Mini dual lumen microballoon catheter is safe and feasible for delivery of liquid embolic agents for cerebrovascular embolization procedures.

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

A Study on the Factors of Safety Enhancement in Mass Casualty Incidents (다수 환자 발생 시 안전 증진 요인에 관한 연구)

  • Lee, Jeong-Hyeok;Park, Joung-Je;Kim, Bo-Kyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.4
    • /
    • pp.229-240
    • /
    • 2019
  • Korea is experiencing various disasters both natural and artificial. This study is descriptive research designed to examine the perception of the disaster response ability of fire-paramedics during the response stage of disaster management. The subjects of this study were EMT-P's who had more than 2 years of experience in the field at a fire station in G Province. The questionnaire, including the items for the sub-factors of the field response ability, were prepared and 161 final questionnaires were collected and analyzed with the SPSS program. The mean scores of triage ability, patient treatment ability, patient transfer ability, disaster support ability, and disaster response speed were 3.53, 3.68, 3.66, 2.95, and 3.44, respectively. As a result of multiple regression analysis, variables affecting the speed of disaster response were in the order of patient treatment ability, patient transfer ability, and disaster support ability. In conclusion, fire-paramedics will have to consider the ability to treat patients, transfer patients, and disaster support to improve disaster response speed, and, ultimately, disaster response guidelines should be developed to improve disaster response capabilities.