• Title/Summary/Keyword: Patient Safety Management

Search Result 452, Processing Time 0.285 seconds

Safety of low-dose anticoagulation in extracorporeal membrane oxygenation using the Permanent Life Support System: a retrospective observational study

  • Kyungsub Song;Jae Bum Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.3
    • /
    • pp.276-282
    • /
    • 2023
  • Background: Bleeding and thrombosis are major complications associated with high mortality in extracorporeal membrane oxygenation (ECMO) management. Anticoagulant therapy should be adequate to reduce thrombosis. However, related studies are limited. Methods: We retrospectively reviewed all patients supported with ECMO at a single institution between January 2014 and July 2022 and included those on all types of ECMO using the Permanent Life Support System. Patients were classified into two groups according to their measured mean activated partial thromboplastin time (aPTT) during ECMO management: a high-anticoagulation (AC) group (aPTT, ≥55 seconds; n=52) and a low-AC group (aPTT, <55 seconds; n=79). The primary outcome was thrombotic or bleeding events during ECMO. Results: We identified 10 patients with bleeding; significantly more of these patients were in the high-AC group (n=8) than in the low-AC group (15.4% vs. 2.5%, p=0.01). However, thrombus events and oxygenator change-free times were not significantly different between the two groups. Four patients in the high-AC group died of bleeding complications (brain hemorrhage, two; hemopericardium, one; and gastrointestinal bleeding, one). One patient in the low-AC group developed a thrombus and died of ECMO dysfunction due to circuit thrombosis. Conclusion: Heparin did not significantly improve thrombotic outcomes. However, maintaining an aPTT of ≥55 seconds was a significant risk factor for bleeding events, especially those associated with mortality.

Management of complications related to colorectal endoscopic submucosal dissection

  • Tae-Geun Gweon;Dong-Hoon Yang
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.423-432
    • /
    • 2023
  • Compared to endoscopic mucosal resection (EMR), colonoscopic endoscopic submucosal dissection (C-ESD) has the advantages of higher en bloc resection rates and lower recurrence rates of colorectal neoplasms. Therefore, C-ESD is considered an effective treatment method for laterally spread tumors and early colorectal cancer. However, C-ESD is technically more difficult and requires a longer procedure time than EMR. In addition to therapeutic efficacy and procedural difficulty, safety concerns should always be considered when performing C-ESD in clinical practice. Bleeding and perforation are the main adverse events associated with C-ESD and can occur during C-ESD or after the completion of the procedure. Most bleeding associated with C-ESD can be managed endoscopically, even if it occurs during or after the procedure. More recently, most perforations identified during C-ESD can also be managed endoscopically, unless the mural defect is too large to be sutured with endoscopic devices or the patient is hemodynamically unstable. Delayed perforations are quite rare, but they require surgical treatment more frequently than endoscopically identified intraprocedural perforations or radiologically identified immediate postprocedural perforations. Post-ESD coagulation syndrome is a relatively underestimated adverse event, which can mimic localized peritonitis from perforation. Here, we classify and characterize the complications associated with C-ESD and recommend management options for them.

The Utility of Used a Blowing Agent in PET/CT (발포제를 이용한 PET/CT의 유용성)

  • Kim, Ki-Jin;Rhim, Jae-Dong;Yoo, Se-Jong;Kim, Jeong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.111-117
    • /
    • 2015
  • When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The study enrolled 30 patients who patient with uptake in stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was $61.7{\pm}9.7mm$, horizontal length was $102.5{\pm}17.6mm$ and the vertical length of the Blowing agent group was $74.1{\pm}10.7mm$, horizontal length was $101.5{\pm}14.8mm$ in transverse section. Stomach extension was described as the vertical length of the Water drink group was $109.3{\pm}18.8mm$, horizontal length was $62.7{\pm}18.4mm$ and the vertical length of the Blowing agent group was $123.1{\pm}23.1mm$, horizontal length was $87.6{\pm}14.9mm$ in coronal section. Water drink group SUV decreased 35% and Blowing agent group SUV decreased 56%. Blowing agent group extension was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.

A Study on the Space Organization and Facility Equipment of Medical Laboratory - focusing on the USA, UK and Germany - (병원 진단검사의학부의 공간구조와 설비기준에 대한 조사 - 미국, 영국, 독일을 중심으로 -)

  • Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.3
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: As medicare services have gotten spreaded, clinical laboratory has been dominant position. So, it has been acted for quality control and clinical pathology accreditation. But there has been quite deficient information to evaluate working space and technical standards of medical laboratory for accreditation. This study goals to figure out accreditation standard and design guideline for clinical laboratory, and to give safe and efficient design information. Methods: This study has been searched by literature for accreditation standards and design guidelines of clinical pathology in USA, UK, and Germany. Results: Three countries have accredited based on working lab space, staff space, storage space, patient space and health and safety equipment. Design guidelines of three countries commonly have focused on worktable layout, worktable distance and module, and specific laboratory biosafety level. And USA guidelines stress on the architectural design such as design process and passage distance for escape, UK stress on the efficiency as functional work flow and construction cost, lastly Germany design guidelines stress on the operator's safety distance and workstation. Three countries have not only accreditation standards but also design guidelines for more specific quality management, separating from accrediting institute. Implications: In korea, it has been needed to make clinical laboratory design guideline for the safe and efficient environment and reliable and competitive medical service.

The Feasibility and Future Prospects of Robot-Assisted Surgery in Gastric Cancer: Consensus Comments from the National Evidence-based Collaborating Agency Round-Table Conference

  • Shin, Eunhee;Choi, Jieun;Seo, Seongwoo;Lee, SeonHeui
    • Health Policy and Management
    • /
    • v.25 no.2
    • /
    • pp.67-70
    • /
    • 2015
  • To establish an appropriate policy for robotic surgery in Korea, the National Evidence-based Collaborating Agency (NECA) and the Korean Society of Health Policy and Administration held a round-table conference (RTC) to gather opinions through a comprehensive discussion of scientific information in gastric cancer. The NECA RTC is a public discussion forum wherein experts from diverse fields and members of the lay public conduct in-depth discussions on a selected social issue in the health and medical field. For this study, representatives from the medical field, patient groups, industry, the press, and policy makers participated in a discussion focused on the medical and scientific evidence for the use of robotic surgery in gastric cancer. According to the RTC results, robotic surgery showed more favorable results in safety and efficacy than open surgery and it is similar to laparoscopy. When the cost-effectiveness of robotic surgery and laparoscopy is compared, robotic surgery costs are higher but there was no difference between the two of them in terms of effectiveness (pain, quality of life, complications, etc.). In order to resolve the high cost issue of the robotic surgery, a proper policy should be implemented to facilitate the development of a cost-effective model of the robotic surgery equipment. The higher cost of robotic surgery require more evidence of its safety and efficacy as well as the cost-effectiveness issues of this method. Discussions on the national insurance coverage of robotic surgery seems to be necessary in the near future.

L-carnitine vs Extracorporeal Elimination for Acute Valproic acid Intoxication: A Systematic Review (급성 Valproic acid 중독에서 L-carnitine과 체외 제거방법: 체계적 고찰)

  • Yang, Byung Keun;Ku, Jae Eun;Joo, Young Seon;You, Je Sung;Chung, Sung Phil;Lee, Hahn Shick
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.12 no.2
    • /
    • pp.39-45
    • /
    • 2014
  • Purpose: The purpose of this study is to review the evidence comparing the efficacy and safety between L-carnitine and extracorporeal elimination therapy in the management of acute valproic acid L-carnitine vs Extracorporeal Elimination for Acute Valproic acid Intoxication Methods: PubMed, Embase, Cochrane library, Web of Science, KoreaMed, KMbase, and KISS were searched, using the terms carnitine and valproic acid. All studies, regardless of design, reporting efficacy or safety endpoints were included. Reference citations from identified publications were reviewed. Both English and Korean languages were included. Two authors extracted primary data elements including poisoning severity, presenting features, clinical management, and outcomes. Results: Thirty two articles including 33 cases were identified. Poisoning severity was classified as 3 mild, 11 moderate, and 19 severe cases. Nine cases were treated with L-carnitine while 24 cases received extracorporeal therapy without L-carnitine. All patients except one expired patient treated with hemodialysis recovered clinically and no adverse effects were noted. A case report comparing two patients who ingested the same amount of valproic acid showed increased ICU stay (3 vs 11 days) in case of delayed extracorporeal therapy. Conclusion: Published evidence comparing L-carnitine with extracorporeal therapy is limited. Based on the available evidence, it is reasonable to consider L-carnitine for patients with acute valproic acid overdose. In case of severe poisoning, extracorporeal therapy would also be considered in the early phase of treatment.

  • PDF

Comparison between Gel Pad Cooling Device and Water Blanket during Target Temperature Management in Cardiac Arrest Patients

  • Jung, Yoon Sun;Kim, Kyung Su;Suh, Gil Joon;Cho, Jun-Hwi
    • Acute and Critical Care
    • /
    • v.33 no.4
    • /
    • pp.246-251
    • /
    • 2018
  • Background: Target temperature management (TTM) improves neurological outcomes for comatose survivors of out-of-hospital cardiac arrest. We compared the efficacy and safety of a gel pad cooling device (GP) and a water blanket (WB) during TTM. Methods: We performed a retrospective analysis in a single hospital, wherein we measured the time to target temperature ($<34^{\circ}C$) after initiation of cooling to evaluate the effectiveness of the cooling method. The temperature farthest from $33^{\circ}C$ was selected every hour during maintenance. Generalized estimation equation analysis was used to compare the absolute temperature differences from $33^{\circ}C$ during the maintenance period. If the selected temperature was not between $32^{\circ}C$ and $34^{\circ}C$, the hour was considered a deviation from the target. We compared the deviation rates during hypothermia maintenance to evaluate the safety of the different methods. Results: A GP was used for 23 patients among of 53 patients, and a WB was used for the remaining. There was no difference in baseline temperature at the start of cooling between the two patient groups (GP, $35.7^{\circ}C$ vs. WB, $35.6^{\circ}C$; P=0.741). The time to target temperature (134.2 minutes vs. 233.4 minutes, P=0.056) was shorter in the GP patient group. Deviation from maintenance temperature (2.0% vs. 23.7%, P<0.001) occurred significantly more frequently in the WB group. The mean absolute temperature difference from $33^{\circ}C$ during the maintenance period was $0.19^{\circ}C$ (95% confidence interval [CI], $0.17^{\circ}C$ to $0.21^{\circ}C$) in the GP group and $0.76^{\circ}C$ (95% CI, $0.71^{\circ}C$ to $0.80^{\circ}C$) in the WB group. GP significantly decreased this difference by $0.59^{\circ}C$ (95% CI, $0.44^{\circ}C$ to $0.75^{\circ}C$; P<0.001). Conclusions: The GP was superior to the WB for strict temperature control during TTM.

Postmastectomy Breast Reconstruction is Safe in Patients on Chronic Anticoagulation

  • Yan, Maria;Kuruoglu, Doga;Boughey, Judy C.;Manrique, Oscar J.;Tran, Nho V.;Harless, Christin A.;Martinez-Jorge, Jorys;Nguyen, Minh-Doan T.
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.346-351
    • /
    • 2022
  • Background Postmastectomy breast reconstruction (PMR) increases patient satisfaction, quality of life, and psychosocial well-being. There is scarce data regarding the safety of PMR in chronic anticoagulated patients. Perioperative complications can reduce patient satisfaction; therefore, it is important to elucidate the safety of PMR in these patients. Methods A retrospective case-control study of patients who underwent PMR with implants and were on chronic anticoagulation was performed at our institution. Inclusion criteria were women ≥ 18 years old. Exclusion criteria included autologous reconstructions, lumpectomy, and oncoplastic procedures. Two controls for every one patient on anticoagulation were matched by age, body mass index, radiotherapy, smoking history, type of reconstruction, time of reconstruction, and laterality. Results From 2009 to 2020, 37 breasts (20 patients) underwent PMR with implant-based reconstruction and were on chronic anticoagulation. A total of 74 breasts (40 patients) who had similar demographic characteristics to the cases were defined as the control group. Mean age for the case group was 53.6 years (standard deviation [SD] = 16.1), mean body mass index was 28.6 kg/m2 (SD = 5.1), and 2.7% of breasts had radiotherapy before reconstruction and 5.4% after reconstruction. Nine patients were on long-term warfarin, six on apixaban, three on rivaroxaban, one on low-molecular-weight heparin, and one on dabigatran. The indications for anticoagulation were prior thromboembolic events in 50%. Anticoagulated patients had a higher risk of capsular contracture (10.8% vs. 0%, p = 0.005). There were no differences regarding incidence of hematoma (2.7% vs. 1.4%, p = 0.63), thromboembolism (5% vs. 0%, p = 0.16), reconstructive-related complications, or length of hospitalization (1.6 days [SD = 24.2] vs. 1.4 days [SD = 24.2], p = 0.85). Conclusion Postmastectomy implant-based breast reconstruction can be safely performed in patients on chronic anticoagulation with appropriate perioperative management of anticoagulation. This information can be useful for preoperative counseling on these patients.

Medical disputes related to advanced endoscopic procedures with endoscopic retrograde cholangiopancreatography or endoscopic ultrasonography for the management of pancreas and biliary tract diseases

  • Yoon Suk Lee;Jae-Young Jang;Jun Yong Bae;Eun Hye Oh;Yehyun Park;Yong Hwan Kwon;Jeong Eun Shin;Jun Kyu Lee;Tae Hee Lee;Chang Nyol Paik
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.499-509
    • /
    • 2023
  • Background/Aims: This study aimed to evaluate the characteristics of endoscopic retrograde cholangiopancreatography (ERCP) or endoscopic ultrasonography (EUS)-related adverse events (AEs) that eventually lead to medical disputes or claims on medical professional liability. Methods: Medical disputes for ERCP/EUS-related AEs filed in the Korea Medical Dispute Mediation and Arbitration Agency between April 2012 and August 2020 were evaluated using corresponding medical records. AEs were categorized into three sections: procedure-related, sedation-related, and safety-related AEs. Results: Among a total of 34 cases, procedure-related AEs were 26 (76.5%; 12 duodenal perforations, 7 post-ERCP pancreatitis, 5 bleedings, 2 perforations combined with post-ERCP pancreatitis); sedation-related AEs were 5 (14.7%; 4 cardiac arrests, 1 desaturation), and safety-related AEs were 3 (8.8%; 1 follow-up loss for stent removal, 1 asphyxia, 1 fall). Regarding clinical outcomes, 20 (58.8%) were fatal and eventually succumbed to AEs. For the types of medical institutions, 21 cases (61.8%) occurred at tertiary or academic hospitals, and 13 (38.2%) occurred at community hospitals. Conclusions: The ERCP/EUS-related AEs filed in Korea Medical Dispute Mediation and Arbitration Agency showed distinct features: duodenal perforation was the most frequent AE, and clinical outcomes were fatal, resulting in at least more than permanent physical impairment.

A Study on Information System for Safe Transportation of Emergency Patients in the Era of Pandemic Infectious Disease (팬데믹 감염병 시대에 안전이송을 위한 정보시스템 연구)

  • Seungyong Kim;Incheol Hwang;Dongsik Kim
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.839-846
    • /
    • 2022
  • Purpose: To secure the safety of firefighters who are dispatched to emergency activities for patients with suspected infectious diseases during an epidemic, and to identify the current status of suspected infectious disease patients by region based on the information collected at the site, and manage firefighting infectious diseases that can be controlled and supported I want to develop a system. Method: Develop a smartphone app that can classify suspected infectious disease patients to check whether an infectious disease is suspected, and develop a disposable NFC tag for patient identification to prevent infection from suspected infectious disease patients. Develop a management system that collects and analyzes data related to emergency patients with suspected infectious disease input from the field and provides them to relevant business personnel to evaluate whether the transport of emergency patients with suspected infectious disease is improved. Result: As a result of the experiment, it was possible to determine whether an infectious disease was suspected through the algorithm implemented in the smartphone app, and the retransfer rate was significantly reduced by transferring to an appropriate hospital. Conclusion: Through this study, the possibility of improving emergency medical services by applying ICT technology to emergency medical services was confirmed. It is expected that the safety of paramedics will be actively secured.