• Title/Summary/Keyword: Patent foramen ovale (PFO)

Search Result 6, Processing Time 0.015 seconds

Percutaneous Patent Foramen Ovale Closure After Stroke

  • Oh-Hyun Lee;Jung-Sun Kim
    • Korean Circulation Journal
    • /
    • v.52 no.11
    • /
    • pp.801-807
    • /
    • 2022
  • Percutaneous patent foramen ovale (PFO) closure in patients with a prior PFO-associated stroke showed a risk reduction of the stroke recurrence compared to the medical therapy alone in recent several studies. Nevertheless, optimal patient selection for PFO closure has not been clarified. In this paper, we discuss the characteristics of PFO-associated strokes and discuss the recently published evidence and patient selection for PFO closure in patients with ischemic stroke. The lesions characteristics of PFO-associated stroke are associated with multiple scattered lesion, small sized cerebral cortical lesion, or posterior circulation. Overcoming the failure of early studies in CLOSURE I, PC, and RESPECT trials, PFO closure showed a significant reduction in recurrent stroke in recently published REDUCE, CLOSE, DEFENSEPRO trials, and long-term follow-up data of RESPECT study. However, considering that PFO closure cannot completely prevent stroke recurrence and that complications including atrial fibrillation, we should be selectively performed in patients with high-risk PFO.

Prevalence of Patent Foramen Ovale and Diagnostic Efficacy of Transcranial Doppler Sonography in Cryptogenic Ischemic Stroke Patients

  • Kim, Dae-Sik;Kim, Byung-Weon;Cho, Sung-Jun
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • The prevalence of patent foramen ovale (PFO) in healthy persons was estimated as about $10{\sim}25%$ and was up to 40% in patients with stroke. Transesophageal echocardiography (TEE) was considered to be the most sensitive method to detect PFO and was used as the gold standard. Transcranial doppler sonography (TCD) of the middle cerebral artery (MCA) during a contrast (saline bubble) injection has recently been proposed as an alternative detecting method for PFO. In this study, we would like to know the difference between TCD value and TEE value in subjects with cryptogenic ischemic stroke. We performed TCD and TEE tests to detect PFO on 64 patients (30 women and 34 men, mean age was 59.4 years) with cryptogenic ischemic stroke. PFO prevalence through TCD was 45.3% (29 of 64 patients) and the prevalence through TEE was 34.4% (22 of 64 patients). There was no statistical significance between PFO test and TCD test (P=0.206). But TCD had a sensitivity of 90.9% (20 of 22 patients), specificity of 78.6% (33 of 42 patients), positive predictive value of 69.0% (20 of 29 patients), and negative predictive value of 94.3% (33 of 35 patients). We concluded that TCD was a highly sensitive method for detecting a right-left shunt. Therefore, the non-invasive TCD test is a method more effective than the anti-invasive TEE test in the cost and evaluation of the existence or nonexistence of right to left shunt in addition to the screening method of the cerebrovascular disorder. Considering these points, TCD test could be recommended for patients with cryptogenic ischemic stroke as a useful and convenient method for screening of the existence or nonexistence of a right to left shunt caused by PFO.

  • PDF

Congenital Tricuspid Stenosis - Report a Case - (선천성 삼첨판막협착증의 외과적 치험 ( 1례 ))

  • 이재진
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.672-676
    • /
    • 1989
  • We experienced a case of congenital tricuspid stenosis. The patient was 5 years old boy. The 2D-echo 4 cardiac catheterization with cineangiogram revealed as Tricuspid Stenosis, associated with functioning patent foramen ovale & mild R.V hypoplasia. The lesion was successfully corrected by TV commissurotomy & closure of PFO. Postoperatively, moderate degree of tricuspid regurgitation was remained.

  • PDF

Patent Foramen Ovale Complicated with Chronic Mitral Valvular Insufficiency in A Mixed Dog (잡종 개에서 이첨판 폐쇄 부전증이 합병된 난원공 개존증)

  • Lee, Dong-Guk;Han, Suk-Hee;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.468-472
    • /
    • 2013
  • A 12-year-old intact female mixed dog (weighing 6.2 kg) was referred with primary complaints of severe abdominal distension, persistent coughing and exercise intolerance. Diagnostic studies found ascites, jugular distension, loud left and right apical systolic (grade 4/6) murmur, generalized cardiomegaly with caudal vena cava distension and left atrial dilation. Echocardiographic findings were consistent with degenerative mitral and tricuspid valve endocardiosis and bi-ventricular congestive heart failure. There was also a left to right shunting patent foramen ovale. The LV systolic function is depressed relative to the degree of volume overload. Based on diagnostic findings, this case was diagnosed as PFO complicated with mitral and tricuspid valve endocardiosis with ISACHC IIIa heart failure. The dog was treated with furosemide (2 mg/kg, q12hr, PO), sildenafil (1 mg/kg, q8hr, PO), pimobendan (0.3 mg/kg, q12hr, PO), enalapril (0.5 mg/kg, q12hr, PO) and spironolactone (1 mg/kg, q12hr). The clinical signs were gradually improved after medical therapy.

Surgical Treatment of Endocardial Cushion Defects (A Report of 5 Cases) (심내막상 결손증 치험 5례)

  • 류지윤
    • Journal of Chest Surgery
    • /
    • v.21 no.3
    • /
    • pp.574-582
    • /
    • 1988
  • Endocardial cushion defects is a rare congenital heart disease. We experienced two complete endocardial cushion defects[ECD] and three partial ones, which were successfully repaired between 1986 and 1987. In a patient of complete ECD, associated with secundum ASD, Pulmonary stenosis and Down`s syndrome, the atrial and ventricular septal defects were closed separately with bovine pericardium and Dacron patches respectively, and then pulmonary stenosis was relieved by transannular patch widening in addition to valvotomy and infundibulectomy. In another patient with complete ECD, small interventricular communication was closed with simple suture with pledget and primum ASD was closed with pericardial patch. In first patient of partial ECD, primum atrial septal defect was closed with pericardial patch. In second patient of partial ECD, associated with secundum ASD, direct closure of secundum ASD and patch closure of primum ASD were performed. In third patient of partial ECD, associated with patent foramen ovale[PFO], primum ASD was closed with bovine pericardial patch and PFO was closed directly. In all patient except third patient of partial ECD, mitral clefts were closed with three or four 5-0 prolene interrupted sutures. Transient A-V dissociation developed postoperatively in two patients and transient nodal rhythm developed postoperatively in other two patients. Heart failure in complete ECD with Down`s syndrome was overcome with medical treatment.

  • PDF

Comparison of the Right-to-left Shunt Test by Transcranial Doppler Based on the Addition of Blood and Patient Posture (경두개 초음파를 이용한 좌우단락검사 시 Blood 사용 유무와 환자 자세에 따른 실증적 결과 비교)

  • Kun-Woo KANG;Eui-Jeong LEE;Hyun-Kyung LEE;Eun-Son LEE;Yang-Hee LIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Using transcranial doppler ultrasonography (TCD) to measure the presence or absence of abnormalities in patent foramen ovale (PFO) is more effective than transesophageal echocardiography (TEE) because it is simple, inexpensive, and non-invasive. Thus, it can be a good alternative test in cases where it is difficult to perform TEE or in groups at a high risk of complications. Therefore, in this study, we sought to assist in arriving at a diagnosis by suggesting an appropriate method through the comparison of empirical results according to the presence or absence of blood use and varying patient posture. The results were compared depending on the patient's posture and whether blood was used. Patients in whom both middle cerebral arteries were observed were targeted. In cases where the temporal window was defective, it was replaced with basilar artery and compared. There were higher positivity rate and accuracy for sitting position using valsalva maneuver (VM) than for Resting and supine position using VM. Therefore, if it is possible to perform a sitting position using VM with a mixture of blood, it would be a good idea to perform it.