• Title/Summary/Keyword: Patellofemoral bones

Search Result 2, Processing Time 0.056 seconds

Convergent Study of Personalized Modeling and 5-Axis Machining Technology Using Patellofemoral Bone DICOM Image (넙다리무릎뼈 의료용 디지털 영상 및 통신 표준 영상을 이용한 맞춤형 모델링과 5축 가공기술의 융합적 연구)

  • Yoon, Jae-Ho;Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.137-143
    • /
    • 2018
  • DICOM images of patellofemoral bones were converted into a stereolithography file, and a Unigraphics CAD program was used to create a CAD modeling in which there exists point, line and facet information. The modeling extraction of joint facets was performed by linking two adjacent points into lines in the stereolithography file by using the Unigraphics rapid spacing function and then linking the lines into facets to complete the entire modeling. This modeling extraction was performed based on the anatomical knowledge of joint facet directions. As a result, a personalized space modeling and solid modeling were produced for the joint facets of patellofemoral bones. This was followed by a CAM control computing operation of solid modeling on graphite materials and 5-axis machining of patellofemoral bones. That is the description of a method for a personalized implant modeling by using DICOM images of patellofemoral bones.

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.