• Title/Summary/Keyword: Passive hydraulic engine mount

Search Result 5, Processing Time 0.017 seconds

Dynamic Analysis of Switchable Hydraulic Engine Mount with an Inertia Track and a Decoupler (유체봉입 마운트의 유로 조절에 따른 진동감쇠 성능향상)

  • Ahn, Young Kong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.80-86
    • /
    • 2017
  • This paper describes switching method of the cross-sectional area of the fluid passage way to improve the performance of a hydraulic engine mount with an inertia track and a decoupler. The mount has nonlinear dynamic characteristics depending on the vibrational frequency and amplitude. For the convenience of analysis, two linear motion equations were derived on the basis of the mechanical model according to the low-and high-frequencies. The properties of the transmissibility and dynamic stiffness derived from the equations were investigated according to switching the cross-sectional area of the inertia track and decoupler. Switching method of the cross-sectional area can be derived from the transmissibility plot. In comparison between transmissibility of passive and switchable mounts with an inertia track and a decoupler, the performance of the switchable mount is improved greatly than the passive mount. The resonant peak is remarkably reduced in the high frequency region.

MODELING AND PARAMETER IDENTIFICATION FOR A PASSIVE HYDRAULIC MOUNT

  • Zhang, Y.X.;Zhang, J.W.;Shangguan, W.B.;Feng, Q.Sh.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.233-241
    • /
    • 2007
  • A lumped parameter model is proposed for the analysis of dynamic behaviour of a Passive Hydraulic Engine Mount (PHEM), incorporating inertia track and throttle, which is characterized by effective and efficient vibration isolation behaviour in the range of both low and high frequencies. Most of the model parameters, including volume compliance of the throttle chamber, effective piston area, fluid inertia and resistance of inertia track and throttle are identified by an experimental approach. Numerical predictions are obtained through a finite element method for responses of dynamic stiffness of the rubber spring. The experiments are made for the purpose of PHEM validation. Comparison of numerical results with experimental observations has shown that the present PHEM achieves good performance for vibration isolation.

Optimal Design of Electromagnetic Type Active Control Engine Mount in Consideration of Actuator Efficiency (능동 및 수동 특성을 고려한 전자석 구동형 능동 엔진 마운트의 최적화)

  • Lee, Bo-Ha;Lee, Chong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1112-1118
    • /
    • 2007
  • This paper investigates the performance of an electromagnetic type active control engine mount (ACM) recently developed in the laboratory. The ACM employs the basic structure of the conventional hydraulic engine mount of which upper chamber is connected to a dual magnet electromagnetic actuator. The actuator, that essentially replaces the existing decoupler of the conventional passive hydraulic engine mount, actively controls the upper chamber pressure. Using the linearized ACM model incorporated with the actuator dynamics, we suggest an optimal design of ACM, maximizing the actuator efficiency as well as the vibration isolation efficiency.

  • PDF

Modeling and Control of an Engine Mount Using ER Fluids and Piezoactuators (ER 유체와 압전작동기를 이용한 엔진마운트의 모델링 및 제어)

  • Choi, Seung-Hoon;Choi, Young-Tai;Choi, Seung-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.500-510
    • /
    • 1996
  • This paper presents a new prototype of an engine mount for a passenger vehicle featuring ER(elector-rheological) fluids and piezoactuators. Conventional rubber mounts and various types of passive or semi-active hydraulic engine mounts have their own functional aims on the limited frequency band in the board engine operating frequency range. However, the proposed engine mount covers all frequency range of the engine operation. A mathematical model of the proposed engine mount is derived using the bond graph method which is inherently domain, the ER fluid is activated upon imposing electric field for vibration isolation while the piezoactuator. Computer control electric fluid for the ER fluid H.inf. cotrol technique is adopted for the piezoactuator. Computer simulation is undertaken in order to demonstrate isolation efficiency of the engine mount over wide operating frequency range.

Development of 6-DOF Simulator for Active Engine Mounting System (능동형 엔진 마운트 성능 평가를 위한 6축 시뮬레이터 구축)

  • Kim, Jeong-Hoon;Kim, Jae-San;Lee, Han-Dong;Park, Tae-Ik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.520-525
    • /
    • 2011
  • As worldwide concern stands on global warming and greenhouse gases from internal combustion engine, the interests in technologies for a highly efficient powertrain has been increased. Concurrently the investigation to improve the deteriorated NVH, a by-product of energy efficient powertrain, is conducted seriously. The NVH performance of a new type of active engine mount that offers increased advantages over a passive hydraulic mount is examined using a newly developed 6-DOF simulator. The simulator is in the shape of Hexapod Stewart Platform adopting LEMA, a new type of actuator which is patented and commercialized by ACT Inc,, the world wide leader in the design, development, and manufacture of high performance linear electro-magnetic actuators for active vibration control. The target vibration signals of an aimed vehicle at four engine mounts are measured and simulated by 6-DOF simulator at the laboratory. The resulting NVH performances of the new active mounting system at a vehicle and on a simulator are examined and compared. Even though the active mount performance of lab test demonstrates less effective than the result of a real vehicle test, vibration reduction is identified through the simulator.

  • PDF