• 제목/요약/키워드: Passive alignment

검색결과 39건 처리시간 0.03초

수동적 어깨뼈정렬운동과 유지이완기법이 대학생의 머리척추각(C1~C7)에 미치는 영향 비교 (A Comparsion of the Influences on the University Students Craniovertebral Angle of Passive Scapular Alignment Exercise and Hold and Relaxation Technique)

  • 조힘찬;김민지;김보림;김수경;김정은;김지수;박원우;배인한;이석환;엄희지;장명우;장현정;정혜림;조은성;김근조;장상훈
    • 대한물리치료과학회지
    • /
    • 제26권2호
    • /
    • pp.38-45
    • /
    • 2019
  • Purpose: This study purpose to comparison the effects of passive scapular alignment exercise and hold & relaxation technique on craniovertebral angle (C1~C7) with forward head posture due to using variety bag and using computer in healthy subjects. Design: Randomized Controlled Trial. Methods: 22 subjects were divide into two groups: PSAEx group and H/R group two groups. After exercise, the CVA were measured using C7 and tragus. Collected data were statistically analyzed by SPSS 20.2 Results: There were significant differences pre and post the exercise. Conclusion: PSAEx and H/R technique was effective to correct a abnormal CVA posture. The result of this study may helpful as basic data for orthopedic physical therapy.

수동적 어깨뼈 정렬이 작은가슴근 단축된 사람의 등세모근 근활성도에 미치는 영향 (Effects of Passive Scapular Alignment on Electromyographic Activity of Trapezius in People With Shortness of Pectoralis Minor Muscle)

  • 최지영;장준혁;오재섭
    • 한국전문물리치료학회지
    • /
    • 제19권2호
    • /
    • pp.12-19
    • /
    • 2012
  • The purpose of this study was to assess the influence of scapular alignment on the electromyographic (EMG) activity of the trapezius in people with a short pectoralis minor muscle. For the study, we recruited 15 volunteers who had positive results for short on a pectoralis minor muscle length test. We measured the EMG activity of the upper, middle and lower trapezius muscles. The participants lifted their dominant arm to ear level with the thumb up toward the ceiling in the prone position on a table with the shoulder at a flexion angle of 180 degrees and a horizontal abduction angle of 120 degrees. Scapula was manually aligned by an experienced physical therapist prior to arm lift for the scapular alignment condition. A paired t-test was used to compare the effects of scapular alignment on the EMG activity of the trapezius muscles. The EMG activity of the lower trapezius muscle was significantly increased during the test with the scapular alignment compared to that without scapular alignment (p<.05), while the upper trapezius and middle trapezius exhibited no significant difference between the two conditions (p>.05). The findings of this study suggest that a scapular alignment may alter the recruitment of the lower trapezius muscle during arm lifting in the prone position in people with a short pectoralis minor muscle.

대형 코어 폴리머 광도파로를 이용한 가변 광감쇠기 설계 (Design of Variable Optical Attenuators Incorporating Large Core Polymer Waveguides)

  • 조수홍;오민철
    • 한국광학회지
    • /
    • 제16권3호
    • /
    • pp.254-260
    • /
    • 2005
  • 높은 재현성과 함께 효율적인 수동 정렬을 위하여 제안된 대형코어 단일모드 폴리머 광도파로를 이용하여 제작 가능한 폴리머 광도파로 소자인 가변 광감쇠기를 제안하고 삼차원 빔전파 방법을 이용하여 소자의 동작 특성을 파악하고 최적 구조를 설계하였다. 소자의 표면에 집적된 박막 전극 히터에서 발생하는 열로 인해 폴리머 광도파로에서 발생하는 굴절률 분포 변화를 수치해석적으로 구하였으며 이 결과를 이용하여 삼차원 빔전파 해석을 수행하였다. 대형코어 광도파로가 가지는 작은 굴절률 대비로 인해 효과적인 광감쇠 현상을 작은 온도 변화로부터 얻을 수 있음을 확인하였다. 일반 광도파로 VOA에서 섭씨 150도 이상의 온도 변화가 필요한 반면 대형 코아 광도파로 VOA는 섭씨 70도 정도의 온도 변화 만으로도 20 dB 이상의 감쇠를 얻을 수 있었다. 대형코아 광도파로가 가지는 장점인 높은 정렬오차 허용범위와 더불어 낮은 구동전압으로 동작하는 장점을 함께 가지는 가변 광감쇠기 설계를 완성하였다.

Para-sexiphenyl 유기 전기발광소자의 배향 처리 효과 (Molecular alignment effect of para-sexiphenyl organic electroluminescent devices)

  • 이용수;이재혁;박재훈;최종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.443-445
    • /
    • 2000
  • The high mobilitie sallow larger current to be reached under operation in the space charge limited conduction region, hence facilitate access to higher luminance as required for passive matrix panel. In this work, we have investigated the molecular alignment control effect of organic electroluminescent devices. we aligned the p-sexiphenyl(6p) using a simple rubbing treatment. We studied the anisotropic optical properties and electrical characteristics.

  • PDF

Nano-structuring of Transparent Materials by Femtosecond Laser Pulses

  • Sohn, Ik-Bu;Lee, Man-Seop;Chung, Jung-Yong;Cho, Sung-Hak
    • Journal of the Optical Society of Korea
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Using tightly focused femtosecond laser pulses, we produce an optical waveguide and optical devices in transparent materials. This technique has the potential to generate not only channel waveguides, but also three-dimensional optical devices. In this paper, an optical splitter and U-grooves, which are used for fiber alignment, are simultaneously fabricated in a fused silica glass using near-IR femtosecond laser pulses. The fiber aligned optical splitter has a low insertion loss, less than 4㏈, including an intrinsic splitting loss of 3㏈ and excess loss due to the passive alignment of a single-mode fiber. Finally, we demonstrate the utility of the femtosecond laser writing technique by fabricating gratings at the surface and inside the silica glass.

Development of Low Anchoring Strength Liquid Crystal Mixtures for Bistable Nematic Displays

  • Stoenescu, D.;Lamarque-Forget, S.;Joly, S.;Dubois, J.C.;Martinot-Lagarde, Ph.;Dozov, I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.97-100
    • /
    • 2005
  • The recent Bistable Nematic ($BiNem{(R)}$) LCD technology presents long term bistability, high level passive matrix multiplexing and high optical quality. The BiNem device, based on anchoring breaking, needs specific low anchoring strength materials - alignment layers and liquid crystal mixtures. We present here our approach to develop nematic mixtures with wide enough temperature range and low zenithal anchoring energy.

  • PDF

도로선형과 기하구조 연구를 위한 드라이빙 시뮬레이터의 교통안전시설 요소분석 (A Study of driving simulator applications for road safety in geometric design)

  • 정성학
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2008년도 추계학술대회
    • /
    • pp.561-567
    • /
    • 2008
  • The objectives of this study is to: (1) develop how applications for driving simulator of national highway safety designs when those are appeared; (2) examine the degree to which those geometric designs of the horizontal and vertical profile; and (3) search positive safety and passive highway safety design of the point at which highway alignment factors initiate driving safety to facility or highway design.

  • PDF

인접면 삭제와 변위-기반 접착술로 부착한 수용성 튜브를 이용한 절치 돌출의 교정 치료: 증례보고 (Orthodontic correction of bialveolar protrusion by interproximal reproximation and water-soluble tubes bonded with deflection-based bonding technique: A case report)

  • 노유연;임성훈;정서린
    • 대한치과의사협회지
    • /
    • 제55권12호
    • /
    • pp.850-860
    • /
    • 2017
  • Orthodontic treatment with premolar extraction is usually performed to correct bialveolar protrusion. These methods require the use of stiff rectangular working archwire which requires lengthy alignment and leveling before insertion. In this case report, interproximal reproximation was performed instead of extraction. To establish clearance between the archwire and resin domes fixing the archwire, an archwire was inserted into a water-soluble tube before fabricating resin domes. This tube is solved away by the saliva. During fabrication of resin domes, the archwire was deflected intentionally reflecting the displacement of teeth from their ideal position. This can be called as deflection-based bonding (DBB) technique. DBB is different from conventional method of positioning the brackets on its ideal position and then inserting an archwire to align the brackets. Because the orthodontic force of the archwire comes from its deflection from passive configuration, deflecting an archwire as needed can move the teeth more predictably than just bonding brackets on its ideal position. Also, areas with good alignment before orthodontic treatment can be maintained simply by not deflecting the archwire during bonding in these areas. After initial alignment, interproximal reproximation was performed to create 4.8 mm space in the maxillary arch and 4.2 mm space in the mandibular arch. These spaces were closed using orthodontic mini-implant anchorage thus retracting the maxillary incisors 4 mm posteriorly accompanied with 0.7 mm and 0.3 mm distal movement of right and left molars. By using interproximal reproximation and water-soluble tube with DBB, mild bialveolar protrusion was successfully treated without extraction.

  • PDF

롤투롤 공정을 이용한 광정렬 구조 내장형 광소자 연구 (The Study of Optical Device embedded Optical Alignment fabricated by Roll to Roll Process)

  • 조상욱;강호주;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제20권3호
    • /
    • pp.19-22
    • /
    • 2013
  • 고속, 대용량 정보 전송 수요가 급격하게 증가함에 따라 대량생산 및 고효율의 PLC형 집적 광소자의 연구가 증가하고 있다. 본 논문에서는 광소자와 광섬유가 수동 정렬이 가능하도록 일체형 정렬 구조를 제안하였다. 일체형 구조의 광소자는 기본적으로 1채널의 입력부의 광신호를 2채널의 출력부를 통해 분리하는 광분배기 구조이다. 본 연구에서 제안된 일체형 구조의 제작은 롤투롤 공정 기술을 이용하여 제작하고 그 특성을 평가하였다. 롤투롤 공정 기술은 광소자의 제작에 들어가는 시간을 절감하고 연속생산이 가능한 방법이다. 제작된 광소자의 광특성은 1550 nm의 광원을 이용하여 약3.9 dB의 삽입손실과 0.2 dB의 채널 균일도를 나타내었다.