• Title/Summary/Keyword: Passive Ventilation

Search Result 82, Processing Time 0.022 seconds

Development of Straightforward Method of Estimating LMA and LMR using Computational Fluid Dynamics Technology (전산유체역학 기법을 이용한 공기연령 산정 방법의 개발)

  • Park, Se-Jun;Lee, In-Bok;Hong, Se-Woon;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Yun, Nam-Gyu;Kim, Hyung-Gewon;Kwon, Sun-Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.135-144
    • /
    • 2013
  • Ventilation efficiency has an important role in agricultural facilities such as greenhouse and livestock house to keep internally optimum environmental condition. Age-of-air concept allows to assess the ventilation efficiency of an agricultural facility according to estimating the ability of fresh air supply and contaminants emission using LMA and LMR. Most of these methods use a tracer gas method which has some limitations in experiment like dealing unstable and invisible gas. Therefore, the aim of this study was to develop a straightforward method to calculate age-of-air values with CFD simulation which has the advantage of saving computational time and resources and these method can solve the limitations in experiment using tracer gas method. The main idea of LMA computation is to solve the passive scalar transport equation with the assumption that the production of the time scalar throughout the room is uniform. In case of LMR calculation, the transport of the time scalar was reversed compulsively using UDF. The methodology to validate the results of this study was established by comparing with preceding research that had performed a computing LMA and LMR value by laboratory experiments and CFD simulations using tracer gas. As a result, the error was presented similarly level of results of preceding research. Some big errors could be caused by stagnated area and incongruity turbulence model. while the computational time was reduced to almost one fourth of that by preceding research.

The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building (방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구)

  • Kim, Bae-Young;Yoon, Hea-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.

Study on the Passive Shock/Boundary Layer Interaction Control in Transonic Moist Air Flow (습공기 유동에서 발생하는 충격파와 경계층 간섭의 피동제어에 관한 연구)

  • Baek, Seung-Cheol;Kwon, Soon-Bum;Kim, Heuy-Dong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.21-29
    • /
    • 2002
  • In the present study, a passive control method, using a porous wall and cavity system, is applied to the shock wave/boundary layer interactions in transonic moist air flow. The two-dimensional, unsteady, compressible, Navier-Stokes equations, which are fully coupled with a droplet growth equation, are solved by the third-order MUSCL type TVD finite difference scheme. Baldwin-Lomax model is employed to close the governing equations. In order to investigate the effectiveness of the present control method, the total pressure loss of the flow and the time-dependent behaviour of shock motions are analyzed in detail. The computed results show that the present passive control method considerably reduces the total pressure losses due to the shock wave/boundary layer interaction in transonic moist air flow and suppresses the unsteady shock wave motions over the airfoil as well. It is also found that the location of the porous ventilation significantly affects the control effectiveness.

Occurrence and distribution of indoor volatile organic compounds in residential spaces by sampling methods (시료채취 방식에 따른 주거 공간 내 휘발성유기화합물 발생 특성 평가)

  • Lee, Suyeon;Kim, Daekeun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.362-371
    • /
    • 2018
  • Indoor Volatile organic compounds (VOCs) are classified as known or possible toxicants and odorants. This study characterized VOC levels in 11 homes in an area in the capital of Seoul by using two different methods of VOCs sampling, which are the active sampling using a thermal sorption tube and the passive sampling using a diffusion sampler. When using the active sampling method, the total target VOC concentration ranged from 41.7 to $420.7{\mu}g/m^3$ (mean $230.4{\mu}g/m^3$ ; median $221.8{\mu}g/m^3$) during winter and 21.3 to $1,431.9{\mu}g/m^3$ (mean $340.1{\mu}g/m^3$; median $175.4{\mu}g/m^3$) during summer. When using the passive method, 29.6 to $257.5{\mu}g/m^3$ (mean $81.8{\mu}g/m^3$; median $49.4{\mu}g/m^3$) during winter and 1.2 to $5,131.1{\mu}g/m^3$ (mean $1,758.8{\mu}g/m^3$; median $1,375.1{\mu}g/m^3$) during summer. Forty-nine VOCs were quantified and toluene showed the highest concentration regardless of the season and the sampling method studied. The distribution of VOCs was relatively varied by using the active method. However, it showed a low correlation with indoor environmental factors such as room temperature, humidity and ventilation time. The correlation between indoor environmental factors and VOCs were relatively high in the passive method. In particular, these characteristics were confirmed by principal component analysis.

An Analysis on the Safety related to Architectural Elements in Housing (주거 공간 내 건축 구성 요소의 안전성 분석)

  • Yi, Hoon;Lee, Yong-Hee;Jeong, Sang-Kyu
    • KIEAE Journal
    • /
    • v.5 no.4
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this study is to analyze the safety issues with regard to architectural elements in housing. Causes of accidents and threats to health are reviewed for 'safety' aspects. Threats to health tend to draw more attention due to recent increase of SHS and its public perceptions. The majority of victims by accidents in residential houses are on juveniles aged under 14 in bathrooms and living rooms. Non-slip finish materials are recommended to floors for access and circulation and protective pads to furniture edges. Colored glass may increase the safety of the windows in the living room. Handles and non-slip mats will be a good addition for the safety. Human scale design of the kitchen system is mandatory and appropriate size of storages for hazardous equipment are to be provided. Passive air ventilation for better air quality by dwellers in residence is occasionally used whereas large-scale apartments provide mechanical ventilation to supplement the volume of fresh air. Since the internal air quality is proved one of the major causes of atopic and respiratory diseases, steady effort to achive better air quality utilizing appropriate materials, plants and equipment is mandatory. Frequent cleaning and the use of anti-fungus materials are necessary because House Dust Mites are believed to be one of main causes of such diseases.

Energy Saving by Combination of Element Technologies of Zero-Energy House (제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구)

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

A Study on exposure-Worker to Formaldehyde in the Endoscopy Unit of Hospitals (일부 종합병원 내시경실 근무자의 포름알데히드 노출에 관한 연구)

  • Kim, Jeong Hun;Kim, Dae-Jong;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2009
  • To identify relationship between the airborne concentrations of formaldehyde and the causal factors in the endoscope unit of hospitals, a total of 48 workers selected from 4 hospitals (3 university hospitals and 1 national hospital) were investigated. Airborne formaldehyde samples were collected using passive samplers and subsequently analyzed by HPLC according to the OSHA method 1007. The geometric mean(GM) of airborne formaldehyde concentrations was 0.056 ppm (range: 0.003~0.923 ppm). The rates of exceeding exposure limits of OSHA PEL-TWA and NIOSH REL-TWA were 4.2 % and 83.3%, respectively. The STEL GM concentration was 1.428 ppm(range: 0.103~14.773 ppm). Ventilation condition (p=0.001) and temperature (p=0.017) were statistically significant causal factors for the airborne exposure concentration of formaldehyde in the endoscope unit of hospitals. In conclusion, the workers in the endoscope unit of hospitals were highly exposed to formaldehyde, and adequate controls such as appropriate management of ventilation and temperature are recommended to reduce over exposure to formaldehyde.

A Study on Examples of Eco-Friendly School Design - Focusing on School Facilities in USA, Japan and Korea - (학교건축의 친환경적 계획수법에 대한 사례연구 - 미국, 일본, 한국의 학교건축을 중심으로 -)

  • Lee, Ji-Young;Lee, Kyung-Sun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.2
    • /
    • pp.3-14
    • /
    • 2011
  • This study aims to identify differences and lessons in eco-school planning techniques and sustainable design methods by analyzing comparatively green building certification system and the cases of sustainable schools in US, Korea and Japan. As a result of the comparative analysis, green building certification system for school facilities, both domestic and international, is categorized into external environment, energy, materials and resources, and indoor environment. From the case study, it is common that roof garden and biotopes are installed for external environment, while energy saving, passive energy utilization methods for natural lighting and ventilation such as arrangement planning, courtyard, top-light, shading devices, solar panel and insulation by roof garden are most frequently used. Also, storm water uses, water saving equipment and sustainable materials are often introduced for resource savings. Concerns for indoor environment is frequently addressed by introducing natural light and ventilation in the buildings, which makes ultimately a comfortable space.

  • PDF

Impact of standard construction specification on thermal comfort in UK dwellings

  • Amoako-Attah, Joseph;B-Jahromi, Ali
    • Advances in environmental research
    • /
    • v.3 no.3
    • /
    • pp.253-281
    • /
    • 2014
  • The quest for enhanced thermal comfort for dwellings encompasses the holistic utilization of improved building fabric, impact of weather variation and amongst passive cooling design consideration the provision of appropriate ventilation and shading strategy. Whilst thermal comfort is prime to dwellings considerations, limited research has been done in this area with the attention focused mostly on non-dwellings. This paper examines the current and future thermal comfort implications of four different standard construction specifications which show a progressive increase in thermal mass and airtightness and is underpinned by the newly developed CIBSE adaptive thermal comfort method for assessing the risk of overheating in naturally ventilated dwellings. Interactive investigation on the impact of building fabric variation, natural ventilation scenarios, external shading and varying occupants' characteristics to analyse dwellings thermal comfort based on non-heating season of current and future weather patterns of London and Birmingham is conducted. The overheating analysis focus on the whole building and individual zones. The findings from the thermal analysis simulation are illustrated graphically coupled with statistical analysis of data collected from the simulation. The results indicate that, judicious integrated approach of improved design options could substantially reduce the operating temperatures in dwellings and enhance thermal comfort.

Evaluating the Feasibility of a Ground Source Heat pump System for an Elderly Care Center through Simulation Approach (시뮬레이션을 통한 노인 요양 시설의 지열 히트펌프 시스템 적용 가능성 평가)

  • Byonghu Sohn;Young-Sun Kim;Seung-Eon Lee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.39-52
    • /
    • 2023
  • This study analyzes the energy performance of a elderly care center building and the applicability of a ground source heat pump (GSHP) system through simulation approach. For this purpose, a building information modeling (BIM) program and an energy performance calculation program were used. The impact of the mechanical ventilation system on the energy requirements of the heating and cooling system and the indoor environment was also analyzed, focusing on the change in indoor carbon dioxide (CO2) concentration, which is a representative indicator of the indoor environment (air quality). The simulation results showed that the target building exceeds Level 7 in terms of simulated primary energy consumption or actual energy consumption. In addition, it was analyzed that the target building could not maintain the indoor CO2 concentration below the standard concentration by natural ventilation through window opening alone. Combining the GSHP system with the mechanical ventilation system (Case B and Case C) can further reduce the overall energy consumption by reducing the amount of outdoor air introduced by opening windows. The cost savings compared to the baseline case are estimated to be 67.3% for Case A, 63.7% for Case B, 65.5% for Case C, and 42.5% for Case D. It is necessary to analyze the impact of various renewable energy technologies and passive ones on the energy performance and indoor environment of elderly care centers.