• 제목/요약/키워드: Passive Ventilation

검색결과 81건 처리시간 0.024초

전산유체역학 기법을 이용한 공기연령 산정 방법의 개발 (Development of Straightforward Method of Estimating LMA and LMR using Computational Fluid Dynamics Technology)

  • 박세준;이인복;홍세운;권경석;하태환;윤남규;김형권;권순홍
    • 한국농공학회논문집
    • /
    • 제55권6호
    • /
    • pp.135-144
    • /
    • 2013
  • Ventilation efficiency has an important role in agricultural facilities such as greenhouse and livestock house to keep internally optimum environmental condition. Age-of-air concept allows to assess the ventilation efficiency of an agricultural facility according to estimating the ability of fresh air supply and contaminants emission using LMA and LMR. Most of these methods use a tracer gas method which has some limitations in experiment like dealing unstable and invisible gas. Therefore, the aim of this study was to develop a straightforward method to calculate age-of-air values with CFD simulation which has the advantage of saving computational time and resources and these method can solve the limitations in experiment using tracer gas method. The main idea of LMA computation is to solve the passive scalar transport equation with the assumption that the production of the time scalar throughout the room is uniform. In case of LMR calculation, the transport of the time scalar was reversed compulsively using UDF. The methodology to validate the results of this study was established by comparing with preceding research that had performed a computing LMA and LMR value by laboratory experiments and CFD simulations using tracer gas. As a result, the error was presented similarly level of results of preceding research. Some big errors could be caused by stagnated area and incongruity turbulence model. while the computational time was reduced to almost one fourth of that by preceding research.

방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구 (The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building)

  • 김배영;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.

습공기 유동에서 발생하는 충격파와 경계층 간섭의 피동제어에 관한 연구 (Study on the Passive Shock/Boundary Layer Interaction Control in Transonic Moist Air Flow)

  • 백승철;권순범;김희동
    • 한국항공우주학회지
    • /
    • 제30권8호
    • /
    • pp.21-29
    • /
    • 2002
  • 본 연구는 다공벽과 공동을 사용한 피동제어법을 천음속 습공기 유동에서 발생하는 충격파와 경계층 간섭에 적응하였다. 지배방정식은 액적성장 방정식과 완전히 결합된 2차원, 비정상, 압축성 Navier-Stokes 방정식이며, 3차 오더 MUSCL 타입의 TVD 기법을 사용하였다. 또 난류모델로는 Baldwin-Lomax 모델을 적용하였다. 본 연구에서 적용한 제어법의 유용성을 조사하기 위해 유동의 전압손실과 충격파 변위의 시간의존성 거동을 해석하였다. 수치계산 결과로부터 본 연구의 피동제어기법을 통해 천음속 습공기 유동에서 발생하는 충격파/경계층 간섭으로 인한 전압손실이 상당히 감소하였고, 익에서 충격파 운동을 억제하는 것으로 나타났다. 또 다공영역의 위치가 본 연구의 제어법의 효과에 상당한 영향을 준다는 것이 발견하였다.

시료채취 방식에 따른 주거 공간 내 휘발성유기화합물 발생 특성 평가 (Occurrence and distribution of indoor volatile organic compounds in residential spaces by sampling methods)

  • 이수연;김대근
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.362-371
    • /
    • 2018
  • Indoor Volatile organic compounds (VOCs) are classified as known or possible toxicants and odorants. This study characterized VOC levels in 11 homes in an area in the capital of Seoul by using two different methods of VOCs sampling, which are the active sampling using a thermal sorption tube and the passive sampling using a diffusion sampler. When using the active sampling method, the total target VOC concentration ranged from 41.7 to $420.7{\mu}g/m^3$ (mean $230.4{\mu}g/m^3$ ; median $221.8{\mu}g/m^3$) during winter and 21.3 to $1,431.9{\mu}g/m^3$ (mean $340.1{\mu}g/m^3$; median $175.4{\mu}g/m^3$) during summer. When using the passive method, 29.6 to $257.5{\mu}g/m^3$ (mean $81.8{\mu}g/m^3$; median $49.4{\mu}g/m^3$) during winter and 1.2 to $5,131.1{\mu}g/m^3$ (mean $1,758.8{\mu}g/m^3$; median $1,375.1{\mu}g/m^3$) during summer. Forty-nine VOCs were quantified and toluene showed the highest concentration regardless of the season and the sampling method studied. The distribution of VOCs was relatively varied by using the active method. However, it showed a low correlation with indoor environmental factors such as room temperature, humidity and ventilation time. The correlation between indoor environmental factors and VOCs were relatively high in the passive method. In particular, these characteristics were confirmed by principal component analysis.

주거 공간 내 건축 구성 요소의 안전성 분석 (An Analysis on the Safety related to Architectural Elements in Housing)

  • 이훈;이용희;정상규
    • KIEAE Journal
    • /
    • 제5권4호
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this study is to analyze the safety issues with regard to architectural elements in housing. Causes of accidents and threats to health are reviewed for 'safety' aspects. Threats to health tend to draw more attention due to recent increase of SHS and its public perceptions. The majority of victims by accidents in residential houses are on juveniles aged under 14 in bathrooms and living rooms. Non-slip finish materials are recommended to floors for access and circulation and protective pads to furniture edges. Colored glass may increase the safety of the windows in the living room. Handles and non-slip mats will be a good addition for the safety. Human scale design of the kitchen system is mandatory and appropriate size of storages for hazardous equipment are to be provided. Passive air ventilation for better air quality by dwellers in residence is occasionally used whereas large-scale apartments provide mechanical ventilation to supplement the volume of fresh air. Since the internal air quality is proved one of the major causes of atopic and respiratory diseases, steady effort to achive better air quality utilizing appropriate materials, plants and equipment is mandatory. Frequent cleaning and the use of anti-fungus materials are necessary because House Dust Mites are believed to be one of main causes of such diseases.

제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구 (Energy Saving by Combination of Element Technologies of Zero-Energy House)

  • 신현철;장건익
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

일부 종합병원 내시경실 근무자의 포름알데히드 노출에 관한 연구 (A Study on exposure-Worker to Formaldehyde in the Endoscopy Unit of Hospitals)

  • 김정훈;김대종;김현욱
    • 한국산업보건학회지
    • /
    • 제19권3호
    • /
    • pp.195-201
    • /
    • 2009
  • To identify relationship between the airborne concentrations of formaldehyde and the causal factors in the endoscope unit of hospitals, a total of 48 workers selected from 4 hospitals (3 university hospitals and 1 national hospital) were investigated. Airborne formaldehyde samples were collected using passive samplers and subsequently analyzed by HPLC according to the OSHA method 1007. The geometric mean(GM) of airborne formaldehyde concentrations was 0.056 ppm (range: 0.003~0.923 ppm). The rates of exceeding exposure limits of OSHA PEL-TWA and NIOSH REL-TWA were 4.2 % and 83.3%, respectively. The STEL GM concentration was 1.428 ppm(range: 0.103~14.773 ppm). Ventilation condition (p=0.001) and temperature (p=0.017) were statistically significant causal factors for the airborne exposure concentration of formaldehyde in the endoscope unit of hospitals. In conclusion, the workers in the endoscope unit of hospitals were highly exposed to formaldehyde, and adequate controls such as appropriate management of ventilation and temperature are recommended to reduce over exposure to formaldehyde.

학교건축의 친환경적 계획수법에 대한 사례연구 - 미국, 일본, 한국의 학교건축을 중심으로 - (A Study on Examples of Eco-Friendly School Design - Focusing on School Facilities in USA, Japan and Korea -)

  • 이지영;이경선
    • 교육시설 논문지
    • /
    • 제18권2호
    • /
    • pp.3-14
    • /
    • 2011
  • This study aims to identify differences and lessons in eco-school planning techniques and sustainable design methods by analyzing comparatively green building certification system and the cases of sustainable schools in US, Korea and Japan. As a result of the comparative analysis, green building certification system for school facilities, both domestic and international, is categorized into external environment, energy, materials and resources, and indoor environment. From the case study, it is common that roof garden and biotopes are installed for external environment, while energy saving, passive energy utilization methods for natural lighting and ventilation such as arrangement planning, courtyard, top-light, shading devices, solar panel and insulation by roof garden are most frequently used. Also, storm water uses, water saving equipment and sustainable materials are often introduced for resource savings. Concerns for indoor environment is frequently addressed by introducing natural light and ventilation in the buildings, which makes ultimately a comfortable space.

  • PDF

Impact of standard construction specification on thermal comfort in UK dwellings

  • Amoako-Attah, Joseph;B-Jahromi, Ali
    • Advances in environmental research
    • /
    • 제3권3호
    • /
    • pp.253-281
    • /
    • 2014
  • The quest for enhanced thermal comfort for dwellings encompasses the holistic utilization of improved building fabric, impact of weather variation and amongst passive cooling design consideration the provision of appropriate ventilation and shading strategy. Whilst thermal comfort is prime to dwellings considerations, limited research has been done in this area with the attention focused mostly on non-dwellings. This paper examines the current and future thermal comfort implications of four different standard construction specifications which show a progressive increase in thermal mass and airtightness and is underpinned by the newly developed CIBSE adaptive thermal comfort method for assessing the risk of overheating in naturally ventilated dwellings. Interactive investigation on the impact of building fabric variation, natural ventilation scenarios, external shading and varying occupants' characteristics to analyse dwellings thermal comfort based on non-heating season of current and future weather patterns of London and Birmingham is conducted. The overheating analysis focus on the whole building and individual zones. The findings from the thermal analysis simulation are illustrated graphically coupled with statistical analysis of data collected from the simulation. The results indicate that, judicious integrated approach of improved design options could substantially reduce the operating temperatures in dwellings and enhance thermal comfort.

난방을 비롯한 공기조화의 자연조절 방식과 현대적 응용에 관한 고찰 (A Study on the Passive Principle and its Practical Application of Air-conditioning System)

  • 박순관
    • 한국건축시공학회지
    • /
    • 제4권2호
    • /
    • pp.105-112
    • /
    • 2004
  • The objective of this study is to observe today's situation and direction in relation with the natural air-conditioning and heating system to expand the architectural utilization of natural management for human comfort and energy conservation in architectural design. Also this study to provide the fundamental knowledge and. design-techniques on environment-friendly architecture in connection with 'natural idea in architecture'. In accordance with this intention, this thesis is composed of the following contents : 1) to understand the fundermental concepts about natural air-conditioning and heating system, 2) to review the traditional characteristics in Korean and Southeast Asian architecture related to natural air-conditioning and heating system, 3) to examine modern design-techniques in relation with natural air-conditioning and heating system in the selected area, 4) to attempt to synthesize the whole situation. Environment-friendly architecture using natural ideas and design-techniques in architecture is very important architectural aspect in a current architecture, also for the future. In spite of general considerations, it is expected that this study is use to understand the principle and practical application of natural air-conditioning and heating system in architectural design.