• Title/Summary/Keyword: Passive Scan

Search Result 25, Processing Time 0.023 seconds

Development of Automatic Terrain Following Simulator Using Digital Terrain Elevation Data (디지털 지형 고도 데이터를 이용한 자동 지형 추종 시뮬레이터 개발)

  • Jisu Lee;MunGyou Yoo;Hyunju Lee;Ki Hoon Song;Dong-Ik Cheon;Sangchul Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.88-98
    • /
    • 2024
  • In this paper, an Automatic Terrain Following (ATF) Simulator using Digital Terrain Elevation Data (DTED) was proposed. This ATF Simulator consists of a Flight Simulator, a Radar Simulator, and a Terrain Following Computer (TFC) Simulator. DTED and radar scan data generated with DTED were used as the terrain information necessary for terrain following. The ATF Simulator provides three modes of operation: a passive mode that uses DTED, an active mode that uses radar scan data, and a hybrid mode that uses both. We developed an ATF Simulator that could reduce the cost and time required to develop a terrain following system using the LabVIEW development environment and the MATLAB App Designer development environment. It was verified by confirming that the ATF Simulator met all functional requirements.

Studies on the millimeter-wave Passive Imaging System II (밀리미터파 수동 이미징 시스템 연구 II)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.105-110
    • /
    • 2007
  • We have built the millimeter-wave passive imaging system with a lens and mechanical scan antenna. The lens was designed based on optical theory in order to focus millimeter-wane. A full image was taken from image points scanned by Placing antenna at the representative focal plane selectively. An integrated antenna array device for low-loss and low-noise with the array of 4 by 1, where components such as antenna, balun, MMIC, and detector were assembled on a sin91e substrate, and a fermi tapered slot antenna with high-gain and low-side lobe were used for elements of this millimeter-wave passive imaging system. Two dimensional antenna arrangement on focal plane was achieved in this imaging system.

A Study on the Inhibition Effect of Metal Corrosion Using Organic Compound Containing an Amine Group (아민기를 가진 유기물을 사용한 금속의 부식억제효과)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.361-369
    • /
    • 2010
  • A study on the corrosion inhibition of metals is important in many industrial applications (carbon steel, copper, aluminum, SUS 304, nickel). In this study, we investigated the C-V diagrams related to the surface corrosion of metals. It was observed through the SEM that the surface corrosion state of the various metals had the corrosion potential by the scan rate and the organic inhibitor containing an amine group. We determined to measure cyclic voltammetry using the three-electrode system. The measurement of oxidation and reduction ranged from -1350mV to 1650mV. The scan rate was 50, 100, 150, and 200mV/s. It turned out that the C-V characterization of SUS 304 was irreversible process caused by the oxidation current from the cyclic voltammogram. After adding organic inhibitors, the adsorption film was constituted, and the passive phenomena happened. As a result, it was revealed that the inhibition effect of metal corrosion depends on the molecular interaction, and the interaction has influence on the adsorption complex.

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Electrochemistry Characterization of Metal Using Corrosion Inhibitors Containing Amide Functional Group (아미드 작용기를 가진 부식억제제를 사용한 금속의 전기화학적 특성)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.48-56
    • /
    • 2011
  • In this study, we investigated the C-V diagrams and metal surface related to the electrochemistry characterization of metal(nickel, SUS-304). We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. A measuring range was reduced from initial potential to -1350mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150, 200 and 250 mV/s. As a result, the C-V characterization of metal using N,N-dimethylacetamide and N,N-dimethylformamide inhibitors appeared irreversible process caused by the oxidation current from the cyclic voltammogram. After adding organic corrosion inhibitors, adsorption film constituted, and the passive phenomena happened. According to the results by cyclic voltammetry method, it was revealed that the addition of inhibitors containing amide functional group enhances the corrosion resistance properties.

Dielectric Cylinder Optical Amplifier (원통형 유전체 광 증폭기에 대한 연구)

  • 이성수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.146-147
    • /
    • 2000
  • The electromagnetic wave scattering from active objects has only recently attracted attention.$^{(1).(3)}$ Theoretical studies have considered normal-incidence plane-wave interactions with active dielectric cylinders with the prediction of large enhancements in the scattered field for bound mode structures. According to the theory of the electromagnetic wave scattering from a dielectric cylinder, the eigenvector solutions are discrete and have both guided (non-radiative) and leaky (radiative) mode solutions. By using an anti-guiding (leaky) structure instead of a guided structure and scattering at oblique incident angles near critical angle, the scattering resonances predicted by theoretical studies were obtained for the first time. A fine-grained scan of the plane-wave incident angle a reveals the existence of discrete scattering resonances. The diameter and real part of the index of refraction determine the resonant conditions and the imaginary part of the refractive index has a threshold value to make mode up for its radiation loss. The cross coupling between transverse electric (TE) and transverse magnetic (TM) modes is clearly detected for both active and passive scattering as theoretically expected. (omitted)

  • PDF

Phased Array Antenna Using Active Device

  • Seo, Chul-Hun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.306-309
    • /
    • 2004
  • This paper presents a new active antenna consisting of a microstrip patch for the passive radiator, a mixer for frequency conversion, a voltage controlled oscillator (VCO) and a phase detector for phase control. The microwave signal frequency has been converted into intermediate frequency (IF) on the antenna elements by the mixer. The active antenna consists of two ports, the IF port has a transmitted IF signal via power combined to the baseband and the dc control port is under the control of the phase-detector. The input voltage of the VCO is controlled by the phase detector. The scan range of the array is determined by the phase detector and the VCO and is obtained between 30$^{\circ}$ and - 30$^{\circ}$

Electrochemistry Characterization of Nickel Using Ethanolamine Compound Additives (에탄올아민화합물 첨가에 대한 니켈의 전기화학적 특성)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.531-538
    • /
    • 2010
  • The electrochemistry characterization of metal is important in many industrial applications. In this study, we investigated the C-V diagrams related to the electrochemistry characterization of nickel. We determined electrochemical measurement by using cyclic voltammetry with a three electrode system. A measuring range was reduced from initial potential to -1350mV, continuously oxidized to 1650mV and measured to the initial point. The scan rate were 100, 150, 200 and 200mV/s. As a result, the C-V characterization of nickel using ethanolamine and ethylethanolamine inhibitor appeared irreversible process caused by the oxidation current from the cyclic voltammogram. After adding ethanolamine compound additive, adsorption film constituted, and the passive phenomena happened. According to the results by cyclic voltammetry method, it was revealed that the effect of the electrochemistry characterization of nickel depends on ethanolamine structure interaction to adsorption complex.

Islanding detection of grid-connected photovoltaic inverters using Automatic phase-shift method (계통연계형 PV 인버터의 자동 위상 이동법에 의한 고립운전 검출)

  • Yun, Jung-Hyeok;Kim, Heung-Geun;Choi, Jong-Woo;Chun, Tae-Won;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.591-594
    • /
    • 2005
  • Islanding of PV systems occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding Is one of the serious problems in an electric power system connected with dispersed power sources. Also, this scan present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF