• Title/Summary/Keyword: Passengers

Search Result 1,609, Processing Time 0.025 seconds

A study for risk analysis and disater prevention of the passengers when traincar fire on PSD Installed subway (지하철 승강장안전문 설치에 따른 열차 화재시 승객 위험성평가와 방재방안 연구)

  • Hwang, Cheol-Seung;Kim, Dong-Sung;Lee, Sang-Gon;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.555-560
    • /
    • 2007
  • This paper focused on the ways of disater prevention and risk analysis of the passengers setting up the hypothesis when urban rapid transit broke out fire in subway tunnel which is PSD(Platform Screen Door) installed environment. compared the flud dynamic changes and evacuation specifications whether PSD being installed or not, tried to search the effective ways for sustaining passengers safety.

  • PDF

A Study on Application of Ubiquitous Technology for Convenient Environment in Cruise Ship

  • Kim, Hyun;Jang, Won-Kyung;Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Engineering Education Research
    • /
    • v.15 no.5
    • /
    • pp.82-86
    • /
    • 2012
  • These days, the cruise tourist industry is one of the most dynamic and fastest growing components of the leisure industry in the world. Therefore, the cruise ship with ubiquitous technology is expected to enhance the operation efficiency of the ship. It can also provide valuable addition to the ship's service as well as high quality of life to crews and passengers. Since a large number of passengers are dwelling in cruise ship, all passengers are not easy to use ship's facilities, such as restaurants, fitness center, swimming pool and spa at anytime they want. In this paper, passenger service system in ship environment is tested in similar environment and under ship operation condition. We have proposed three applications of ubiquitous technology using Zigbee communication and LabView program.

The Methods to Increase the Connection between KTX and Traditional Trains (고속철도와 기존철도의 연계증진방안)

  • Han Woo-jin
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.551-556
    • /
    • 2004
  • The Korean Train eXpress(KTX) which started in last April has got many complaints of passengers. This is caused by weak connections between KTX and traditional trains. This paper shows the methods to increase the connection in 3 points of view; business, operation and rolling stocks. For the flexible business, it is necessary that the connecting trains must be multi-purposefully for the satisfaction of KTX transferring passengers and existing commuting passengers. And the expanding of free class is needed. A free class is the base of business flexibility. In an operation point of view, I show the method that can decrease pains for getting transfer. Finally, for the effective using of rolling stocks, I propose that TC(trailer with control) car is added to existing locomotive and passenger coach set. In concluding, KTX needs strong connections with traditional trains. This will bring more competitive power with other transportation systems. And that method must get flexible and various service, in addition to effective and minimizing investment.

  • PDF

Strategies for Improvement of Air Quality in Subway Stations (지하철 역사의 공기질 개선방안 연구)

  • Cho, Young-Min;Kwon, Soon-Bark;Park, Duck-Shin;Goo, Hye-Young;Bin, Hyung-Gu;Kim, Hee-Man
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2117-2121
    • /
    • 2010
  • Many passengers complain about the air quality of subway stations, mostly due to the dust. Usually, this dust is usually originated from tunnels, passengers, or outdoor air. As for now, the dust from tunnels and passengers is not easy to control, but relatively easy to control that from outdoor air. In this study, the effect of outdoor air on the subway air quality was investigated, and various factors was found to be effective. Based on these results, some strategies for the improvement of air quality in subway stations were suggested in this study.

  • PDF

Study on the volatile organic compounds and suspended microorganism in a high-speed train passenger cabin (고속열차 객실의 휘발성유기화합물 및 부유미생물 분석 연구)

  • Cho, Young-Min;Jung, Woo-Sung;Park, Duck-Shin;Kwon, Soon-Bark;Park, Eun-Young;Jung, Mi-Young;Mok, Jin-Yong;Lee, Jong-Beom
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1045-1050
    • /
    • 2008
  • The public interest on the indoor air quality of a high-speed train passenger cabin is drastically increasing due to the sealing of cabin. In this study, the concentration of volatile organic compounds and suspended microorganism in the high-speed train passenger cabin was investigated. There have been many studies on the indoor air quality of the high-speed passenger cabin, but the study on the indoor air quality without boarding of passengers were hardly carried out. As a result, it was very difficult to identify the exact source of air pollutants in the cabin. In this study, the indoor air quality of passenger cabin without any passengers was investigated so that the contribution of passengers as the source of various pollutants could be estimated.

  • PDF

Safety Analysis of Carbon Composite-body Against Lightning Strikes (탄소섬유 복합차체의 낙뢰에 대한 안전성 분석)

  • Kim, Sung-Wook;Park, Dae-Won;Kil, Gyung-Suk;Mok, Jae-Kyun;Han, Ju-Seop
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.321-326
    • /
    • 2008
  • Light weight of vehicles by composite materials makes possible high speed, energy saving, and low repair cost. As Bimodal Tram and Tilting Train eXpress(TTX) use carbon composite material for their bodies, safety for passengers and electrical devices against unexpected failures has been issued more than ever. Lightning strike which generates high voltages and large currents is the worst case for the safety of passengers and devices. With this background, we experimentally investigated the insulation breakdown phenomena on carbon composite materials by the application of lightning surge voltage and current. From the experimental results, we could estimate whether the composite body is safe or not for the inside passengers and devices against lightning strikes.

  • PDF

Impact Energy Absorbtion Characteristics Review on the Initial Design of TTX Mcp Car front-end Structure (기존선 틸팅차량 Mcp Car 차체 설계초안의 충돌에너지 흡수특성 고찰)

  • Kwon Tae-Soo;Jung Hyun-Seung;Koo Jeong-Seo;Cho Tae-Min
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.652-656
    • /
    • 2004
  • Crashworthy design of trains is now indispensable procedure in modern railway vehicle design for ensuring the safety of Passengers and crew. It is now widely recognized that a more strategic approach is needed in order to absorb higher level energy in a controlled manner and minimize passenger injuries effectively. The first design step in this strategic approach is the design of the front end structure(so called HE extremities) to absorb a large part of total impact energy and then the structure of passengers non-accommodation zones(so called LE extremities) is designed to absorb the rest of impact energy. In this paper, the passengers entrance door area is selected as the LE(low energy) extremities and the design of the LEE was carried out. The main part of LEE design procedures is the design of energy absorbing tubes. For this purpose, the several tube candidates are introduced and compared to each others with numerical crash simulation.

  • PDF

The investigation on motion sickness for tilting train (틸팅차량의 멀미특성에 대한 고찰)

  • 김남포;신종한
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.834-838
    • /
    • 2002
  • As tilting train is the effective solution to provide faster passenger service on conventional railway lines without too costly modification of infrastructure, it is expected that tilting train will be put into service for Korean conventional Railway Lines. Very few passengers may suffer from motion sickness on conventional train and high speed train. But some sickness among passengers of tilting trains have been reported. Up to now, a standardized motion sickness index was mainly developed in the shipping domain. Therefore, there was a need for railway motion sickness index in order to predict and evaluate the motion sickness which is likely to be experienced by passengers. This paper is the preliminary investigation to propose the technical index related to motion sickness and nausea phenomena for the tilting train development and operation.

  • PDF

A Contact-free type door control System with Proximity Switch (근접센서를 이용한 비접촉 방식의 출입문 감지제어 시스템)

  • Kim sung soo;Lee gi soo;Ahn Cheong Mo;Yoo Ju Hyon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1063-1070
    • /
    • 2005
  • Number of subway train units that Seoul Metropolitan Subway Corporation as at September 2005 is 1.944 on 4 routes from 60 units at the time of commencement of operation, having grown exponentially. Along with increase in the number of passengers the role of subway as safer and expedient means of transportation is now being required. Furthermore, the Corporation has been researching on means of improving the safety and reliability of subway entry/exit doors which has become an essential task and directly effect the safety of the passengers. In this Study, has developed sensory control system for the entry/exit door of the subway train using non-contact proximity sensor as a part of review of and measures against various issues of entry/exit door of the subway trains currently under operation. In addition, this sensor system was verified through test production and tests. If this technology becomes commercialized and practically utilized in the future, it would be able to make definite contribution to the safer transportation of passengers.

  • PDF

Analysis of basic IAQ management factors in metropolitan subway (수도권 지하철 내부의 IAQ 관리 기초 인자 분석)

  • Cho Young-Min;Park Duckshin;Lee Cheulgyu;Park Byunghyun;Park Eunyoung
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1138-1142
    • /
    • 2005
  • The IAQ management in subway cabin is very important for the enhancement of the amenity and health of passengers because the subway carries many passengers in a relatively short time mostly in urban area. However, since the ventilation of most subway cabins are performed by simple opening of doors at each stations, the IAQ management is not easy. In this study, we measured some IAQ factors (temperature, relative humidity, particulate matters, CO, and $CO_2$ concentration) of subway cabin in Seoul area. The results showed that the IAQ of the cabin was relatively acceptable. However, $CO_2$ concentrations were higher than 1,000 ppm in most cases. $CO_2$ concentration was mostly proportional to the number of passengers in cabin. Therefore, new method to relieve the $CO_2$ concentration is urgently required.

  • PDF