• Title/Summary/Keyword: Passed tests

Search Result 148, Processing Time 0.034 seconds

Carrying Capacity Behavior of Instrumented PC Piles (시험 콘크리트 말뚝의 지지력 거동)

  • 이영남;이종섭
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.163-172
    • /
    • 1998
  • To study the carrying capacity behavior of pile, dynamic pile testis and static load tests were carried out on two instrumented piles during and some time after pile driving. Cone Penetration Test( CPT) and Standard Penetration Test(SPT) were also performed at the test site before pile tests to investigate the relationship between unit skin friction of piles and cone tip resistance values and SPT N values. Total static capacity of pile reached the ultimate stage at the pile head settlement of about 0.055D (D : Pile diameter), at which skin friction of Pile already Passed the maximum value, but the end bearing was still increasing with the pile head settlement. The carrying capacity of pile increased in the form of natural logarithmic function with the time after pile driving. The increase in skin friction with time was very substantial the increase in skin friction 40 days after pile driving was 4.6 times of that determined during pile driving. The contribution of skin friction to the total capacity twas insignificant in the beginning, but became substantial 40 days after pile driving. This implies that the tested pile initially responded as an end bearing pile and later behaved as a friction pile. It was also noted that unit skin friction of pile might be ielated to cone tip resistance values(q.) and SPT N values, though the coefficient of this relationship might differ from one soil group to another and was somewhat greater than the value used in the design practice of Korea.

  • PDF

Characteristics of Chloride Diffusion and Compressive Strength in the Mortar containing C12A7 based Binder and Anhydrite (C12A7계 바인더와 무수석고를 혼입한 모르타르의 염화물 확산 및 압축강도 특성)

  • Byeong-Cheol, Lho;Yong-Sik, Yoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2022
  • In this study, as the preliminary research on the development of heating concrete members, compressive strength and accelerated chloride diffusion behavior in the mortar specimens containing C12A7 based binder and anhydrite was evaluated. Also, the effect of the mixing ratio of the citric acid based retarder was quantitatively evaluated by considering 4 levels of mixing cases. The compressive strength tests of the mortar specimen were performed referred to KS L ISO 679, and the accelerated chloride diffusion tests were performed according to NT BUILD 492 and ASTM C 1202. In the mortar with 0.3 % of retarder, the highest compressive strength was evaluated, which showed the strength development ratio of 127.6 % compared to the control case. It was considered that engineering performance was improved by effectively securing setting and curing time with 0.3 % of citric acid based retarder. As the result of the evaluation of the passed charge and the accelerated chloride diffusion coefficient, the evaluation results had similar behavior with the results of compressive strength. According to the previous study, the strength behavior and the chloride diffusion behavior had a linear relationship. The mixture showing the highest strength performance had the highest durability performance for chloride ingress, and the heating concrete development from this study will be performed in the future.

Questions and Answers about the Humidifier Disinfectant Disaster as of February 2017 (가습기살균제 참사의 진행과 교훈(Q&A))

  • Choi, Yeyong
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.1-22
    • /
    • 2017
  • 'The worstest environment disaster', 'World's first biocide massacre', 'Home-based Sewol ferry disaster' are all phrases attached to the recent humidifier disinfectant disaster. In the spring of 2011, four of 8 pregnant women including 1 adult man passed away at a university hospital in Seoul due to breathing failure. Epidemiologic investigation conducted by the Korean CDC soon revealed the inhalation of humidifier disinfectant, which had been widely used in Korea during the winter, to be responsible for the disease. As well as lung fibrosis hardening of the lungs, other diseases including asthma, rhinitis, skin disease, liver disease, fetal disease or cancers have been researched for their relation with exposure to the products. By February 9, 2017, 5,342 cases had registered for health problems and 1,131 of them were already dead (20.8% mortality rate). Based on studies by government agencies and a telephone survey of the general population by Seoul National University and civic groups, around 20% of the general public of Korea has used these products. Since the market release of the first product by SK Chemical in 1994, over 7.1 million items from around 20 brands were sold up to 2011. Most of the products were manufactured by well-known large conglomerates such as SK, Lotte, Samsung, Shinsegye, LG, and GS, as well as some European companies including UK-based Reckitt Benckiser and TESCO, the German firm Henkel, the Danish firm KeTox, and an Irish company. Even though this disaster was unveiled in 2011 by the Korean government, the issue of the victims was neglected for over five years. In 2016, an unexpected but intensive investigation by prosecutors found that Reckitt Benckiser manipulated and concealed animal tests for its own brand and brought several university experts and company employees to court. The matter was an intense social issue in Korea from May to June with a surge in media coverage. The prosecutor's investigation and a nationwide boycott campaign organized by victims and environmental groups against Reckitt Benckiser, whose product had been used by more than 70% of victims, led to the producer's official apology and a compensation scheme. A legislative investigation organized after the April 2016 national election revealed the producers' faults and the government's responsibility, but failed to meet expectations. A special law for the victims passed the National Assembly in January 2017 and a punitive system together with a massive environmental epidemiology investigation are expected to be the only solutions for this tragedy. Sciences of medicine, toxicology and environmental health have provided decisive evidence so far, but for the remaining problems the perspectives of social sciences such as sociology and jurisprudence are highly necessary, similar to with the Minamata disease and Wonjin Rayon events. It may not be easy to follow this issue using unfamiliar terminology from medical and chemical science and the long, complicated history of the event. For these reasons the author has attempted to write this article in a question and answer format to render it easier to follow. The 17 questions are: Q1 What is humidifier disinfectant? Q2 What kind of health problems are caused by humidifier disinfectant? Q3 How many victims are there? Q4 What is the analysis of the 1,112 cases of death? Q5 What is the problem with the government's diagnostic criteria and the solution? Q6 Who made what brands? Q7 Has there been a recall? What is still on sale? Q8 Was safety not checked by any producers? Q9 What are the government's responsibilities? Q10 Is it true that these products were sold only in Korea? Q11 Why and how was it unveiled only in 2011 after 17 years of sales? Q12 What delayed the resolution of the victim issue? Q13 What is the background of the prosecutor's investigation in early 2016? Q14 Is it possible to report new victim cases without evidence of product purchase? Q15 What is happening with the victim issue? Q16 How does it compare with the cases of Minamata disease and Wonjin Rayon? Q17 Are there prevention measures and lessons?

Incidence of hearing loss and importance of risk factors in the neonatal intensive care unit (신생아 중환자실에서 난청의 발생빈도 및 위험요소의 중요성)

  • Kong, Seung Hyun;Kang, Jang Hee;Hwang, Kwang Su;Kim, Joong Pyo;Lee, Hyeon Jung;Choi, Hyeon;Mok, Ji Sun;Kim, Jung Young
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.845-850
    • /
    • 2006
  • Purpose : To assess the incidence of neonatal hearing loss in a neonatal intensive care unit and the relative importance of risk factors for hearing imparement in a neonatal intensive care unit which the Joint Committee on Infant Hearing(JCIH) had recommended. Methods : One thousand, two hundred and one newborns admitted to the Good Moonhwa Intensive Care Unit from May 2003 to December 2005 were assesed using the automated auditory brainstem response(AABR). The screening was performed on those aged more than 36 weeks and weighing more than 2,200 g. We divided the infants into two groups, 'pass' and 'refer'. The 'refer' group were retested one month later, and if classified as 'refer' during the retest, were referred to a hearing impairment clinic. Results : From the 1,201 neonates, 1,187(98.8 percent) passed the test and 14(1.2 percent) failed. 293(24.4 percent) of the 1,201 neonates had a risk factor for hearing impairment; 282(96.2 percent) passed the test and 11(3.8 percent) failed. The group with risk factors were shown to have a higher incidence of hearing loss(P<0.001). The neonates in the refer group were shown to have a higher incidence of ototoxic drugs(P<0.001), low birth weight(<1,500 g)(P<0.001) and craniofacial anomalies(P=0.007). On the other hand, there were no statistical differences between the pass and refer groups in congenital infection, hyperbilirubinemia, bacterial meningitis, low Apgar scores, prolonged mechanical ventilation and syndromes known to include hearing loss. Conclusion : In order to identify hearing-impaired infants within an appropriate period, neonatal hearing screening tests and identification of the risk factors for neonatal hearing loss are important.

Personnel Dosimetry Performance Test (개인방사선 피폭선량판독 성능시험)

  • Na, Seong-Ho;Han, Seung-Jae;Lee, Dew-Hey;Cho, Dae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.131-138
    • /
    • 1996
  • This paper describes the methods and results of the personnel dosimetry performance tests which were been implemented for the first time in Korea in 1995. Seven categories, except the neutron category prescribed in the ANSI N13.11-1993, were adopted in the test. Fifteen types of dosimeters were participated by fourteen dosimeter processing institutes. A total of 129 dosimeters were selected to test-each type - 15 dosimeters for each of the seven categories and 24 for the controls. A total of 144 radiation categories were employed in the test and a total of 2560 (including 400 controls)dosimeters were submitted-7 categories for each type of the fifteen types dosimeters and 39 categories for the retest. The performance index in each category. sum of the absolute value of the bias and the standard deviation value of the performance quotient. was estimated by the use of delivered and processed dose equivalents according to the standard procedure. The performance in a given category was assessed as acceptable, for the deep and shallow dose equivalents (or the absorbed dose), if the performance index was less than 0.5. The test results showed 54% of the processors passed in the first test, 33% in the retest and 13% in the second retest.

  • PDF

Attitudes Toward and the Educative Effect of Basic CPR in Apprentice Doctors in an Oriental Hospital (한방병원 근무 한방수련의의 기본심폐소생술에 대한 태도와 교육 효과)

  • Kim, Mi-Kyung;Seo, Jun-Seok;Lee, Seung-Chul;Lee, Jeong-Hun;Do, Han-Ho;Han, Chang-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.4
    • /
    • pp.892-900
    • /
    • 2010
  • Objectives : To save the lives of patients with cardiac arrests, CPR must be performed rapidly and precisely. Regarding its critical necessity, there is a growing tendency to encourage whomever witnesses the cardiac arrest to perform basic CPR. However, the attitude toward basic CPR nor its current state of education in Korean Oriental Medical arena, which is one of the dual axes unique to Korean medical system, are not known. This is a kind of pilot study to research attitudes toward and the educative effect of basic CPR among oriental medical doctors in Korea. Methods : We carried out surveys and tests targeting nineteen apprentice doctors working in Dongguk University Ilsan Oriental Hospital, who were receiving training for 'AHA BLS course for healthcare providers', on the attitude toward and educative effect of basic CPR before and after the education. Results : The pre-educational survey showed that most of the participants felt the necessity to be trained in the BLS course, were not confident about performing CPR, and not well-acquainted with the whole process of performing CPR. After education, however, none of them responded with a lack of confidence to perform basic CPR, and the score of the confidence to perform basic CPR was significantly increased, too (from $2.05{\pm}0.71$ to $4.05{\pm}0.40$, n=19, p<0.001). Moreover, all of them answered they were satisfied with this BLS course, and it aroused their sense of responsibility as oriental medical doctors. All the participants passed the exam, and their average score for BLS scheme performance was $28.2{\pm}1.3$. Conclusions : It is necessary, in the future, to set up a management system for intensive, regular and continuous reeducation and expand the research on the perception and attitude targeting larger numbers and more multilevel groups of oriental medical doctors.

Comparison of Effects of Mask Style and Donning Training on Fit Factors of Particulate Filtering Facepiece Respirators (안면부 여과식 방진 마스크의 형태 및 착용 방법 교육이 밀착계수에 미치는 영향 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.35-41
    • /
    • 2016
  • Particulate filtering facepiece respirators (PFFR) is one of the most widely used items of personal protective equipments, and a tight fit of the respirators on the wearers is critical for the protection effectiveness. In order to effectively protect the workers through the respirators, it is important to find and evaluate the ways that can be readily applicable at the workplace to improve the fit of the respirators. This study was designed to evaluate effects of mask style (cup or foldable type) and donning training on fit factors (FF) of the respirators, since these are available at various workplace, especially at small business workplace. A total of 40 study subjects, comprised of 30~50s aged male and female workers in metalworking industries, were enrolled in this study. The FF were quantitatively measured before and after training related to the proper donning and use of cup or foldable-type respirators. The pass/fail criterion of FF was set at 100. After the donning training for the cup-type mask, subjects who passed the fit test were increased from 10 to 33. Moreover, the geometric mean (GM) of FF was increased by 340% in subjects who failed the test. In addition, the training effects for the cup-type mask were significant in female and 50s aged subjects. On the other hand, although the GM of FF for the foldable-type mask was also increased after the donning training, the GM of FF for the foldable-type mask and it's increase rate were smaller as compared to the cup-type mask. Furthermore, the differences of the increase rates of the GM of FF in sex and aged of the subjects were not significantly for the foldable-type mask. The multi-distribution of leak points for the foldable-type mask may be one of causes for the less effect of training on the fit of the foldable-type mask. These results imply that the raining on the donning and use of PFFR can enhance the protection effectiveness of cup or foldable-type mask, and that the training effects for the foldable-type mask is less significant than that for the cup-type mask. Therefore, It is recommended that the donning training and fit tests should be conducted before the use of the PFFR, and that efficient tranining programs for the foldable-type mask are required.

Palaeomagnetism of the Okchon Belt, Korea: Paleozoic Rocks in Yemi Area (옥천대에 대한 고자기 연구: 예미지역 고생대 지층의 잔류자기)

  • 김인수;김성욱;최은경
    • Economic and Environmental Geology
    • /
    • v.34 no.4
    • /
    • pp.355-373
    • /
    • 2001
  • Palaeomagnesim of Paleozoic Tuwibong Type Sequence in Yemi area was studied with a total of 256 core-samples collected from 23 sites. The study area (geographical coordinates: 37.l8$^{\circ}$N, l28.610E) is located between Taebaek and Yongwol belonging to the northeastern part of the Okchon Belt. Thermal cleaning was a most effective method to extract stable characteristic remanent magnetization (ChRM) direction, even though AF cleaning also worked on some specimens. Mean ChRM direction of the Cambrian Hwajol Formation was different from the present-day field direction and showed maximum clustering (max. k value) at 100% bedding-tilt correction. However, it could not pass the fold test. Ordovician Makkol and Kosong Limestones as well as Permian Sadong and Kobangsan Formations have very weak NRM, and were remagnetized into the present-day field direction. ChRM directions from the Carboniferous Hongjom Formation passed both fold and reversal tests. IRM experiments and blocking temperature spectrum indicate that both magnetite and haematite are carrier of the primary magnetization. Palaeomagnetic pole position from the Carboniferous Hongjom Formation is very similar to that of contemporary North China Block (NCB) suggesting that the study area was a part of, or located very near to, the NCB during Carboniferous.

  • PDF

Comparative Analysis of TTAK.KO-06.0288-Part3 and Development of an Open-source Communication Library for Greenhouse Control System

  • Kim, Joon Yong;Kim, Sangcheol;Lee, Jaesu
    • Journal of Biosystems Engineering
    • /
    • v.43 no.1
    • /
    • pp.72-80
    • /
    • 2018
  • Purpose: A modern greenhouse consists of various Information and Communications Technology (ICT) components e.g., sensor nodes, actuator nodes, gateways, controllers, and operating softwarethat communicate with each other. The interoperability between these components is an essential characteristic for any greenhouse control system. A greenhouse control system could not work unless the components communicate via common interfaces. The TTAK.KO-06.0288 is an interface standard consisting of four parts. Notably, TTAK.KO-06.0288-Part3, which describes the interface between a greenhouse operating system (GOS) and a greenhouse control gateway (GCG), is the core standard of TTAK.KO-06.0288. The objectives of this study were to analyze the TTAK.KO-06.0288-Part3 standard, to suggest alternative solutions for identified issues, and to develop a library as a proof of the alternative solutions. Methods: The "data field" was analyzed using a comparative analysis method, since it is a data transmission unit of TTAK.KO-06.0288-Part3. It was compared with other parts of TTAK.KO-06.0288 in terms of definition, format, size, and possible values. Although TTAK.KO-06.0288-Part1 and TTAK.KO-06.0288-Part2 do not use a "data field," they have a similar data structure. That structure was compared with the "data field" of TTAK.KO-06.0288-Part3. Results: Twenty-one issues were identified across four categories: inter-standard issues, intra-standard issues, operational issues, and misprint issues. Since some of the issues can raise interoperability problems, 16 alternative solutions were suggested. In order to prove the alternative solutions, an open-source communication library called libtp3 was developed. The library passed 14 unit tests and was adapted to two research. Conclusions: Although TTAK.KO-06.0288-Part3 is an interface standard for communication between a GOS and a GCG, it might not communicate between different implementations because of the identified issues in the standard. These issues could be solved by the alternative solutions, which could be used to revise TTAK.KO-06.0288. In addition, a relevant organization should develop a program for compatibility testing and should pursue test products for smart greenhouses.

Quality Assay of Human Fetal-Cord Serum for Human IVF-ET with Mouse 2-Cell Embryos (생쥐 2-세포배아에 의한 시험관아기 배양용 대아제대혈청의 절적평가에 관한 연구)

  • Moon, S.Y.;Shin, C.J.;Chung, K.M.;Oh, S.K.;Pang, M.G.;Chang, Y.S.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.2
    • /
    • pp.139-146
    • /
    • 1989
  • The purpose of this study was to examine the qualitative variation of human fetal-cord sera (HCS) and to accept the sera in human lVF-ET program. One hundred and sixteenth RCS were tested with 1772 2-cell embryos of F1 (C57BL x CBA) virgin mice, Ten to sixteenth embryos were cultured in m-KRB medium with a aliquot of each serum (10%, v/v) or with bovine serum albumin(O.4%, w/v) as a control medium. Embryonic development were recorded at every 24hr for 4 days by such events as cellular compaction, cavitation, and hatching. In the control groups of eight assays, 98.1%(106/ 108) of 2-ce1l embryos developed above expanded blastocyst and the embryonic development was unified through the tests. But the developmental pattern in medium with each serum was various. Namely, the sera that supported development of 100% 2-cell embryos to above morula, early blastocyst, expanded blastocyst and hatching blastocyst was 45,7%(53/116) , 35.3%(41/116), 15.5%08/116.) and 6.9-%(8/116), respectively. And the sera that supported development of above 80% 2-cell embryos to the each embryonic stage was 92.2% (107/116), 83.6%(97/116), 63.8%(74/116) and 36.2%(42/116), respectively. Meanwhile two kinds of toxic pattern to the embryonic development were observed in some sera. The first pattern is that some sera arrested development of most embryos in pre- or post-stage of morula or blastocyst. The second pattern is that some sera promoted or arrested a part of embryos in the same dish. The ability of serum was depended on the batch of serum. Finally we could accept 69%(80/116) of the tested sera for human IVF-ET program. The base line for acceptance was the ability that supported above 80% 2-ce1l embryos to blastocyst. But some deterious sera were contained in this range. We cut off about 10% of the sera (83.6% , 97/116) that passed the baseline. This final percent of sera was similar to that of grade N of this study.

  • PDF