• Title/Summary/Keyword: Partition-FFT

Search Result 3, Processing Time 0.014 seconds

A Study on the Analysis Method of Tracking Process using Voltage Waveforms (전압파형을 이용한 트래킹 진전과정 분석방법에 관한 연구)

  • Jee, Sung-Wook;Lee, Chun-Ha;Yoon, Dae-Hee;Song, Hyun-Jik;Shim, Kwang-Yul;Park, Won-Ju;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.30-35
    • /
    • 2006
  • Voltage is generally and exactly measured in the electric and electronic field. So, we studied method for detecting electric equipment faulty state using only electric voltage. It is called the Partition-FFT. Tracking is simulated by method and tester proceed on IEC 60112. We analyze voltage waveforms by tracking tester with Partition-FFT. As the result tracking process is clearly distinguished by 6 steps. Tracking is one of the major reason of electric accidents. The Partition-FFT is using a digital oscilloscope and a computer software. If Partition-FFT analysis is applied to the electricity facilities, We can prevent from happenning electric accidents cause of tacking breakdown with low prices and easy measurment. Most of all, Partition-FFT is system that make a visual tacking process. So, everyone is able to detect to possibility of electric accidents.

Frequency-Time Analysis(Partition-FFT) for Tracking Detection (트래킹 검출을 위한 주파수-시간 분석(분할-FFT))

  • Jee S. W.;Lee S. H.;Kim Ch. N.;Lee C. H.;Lee K. S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.530-538
    • /
    • 2004
  • A electromagnetic waves are used for sensing in insulation diagnosis at electric machine or equipment. When it a method, waves are transformed into the FFT(Fast Fourier Transform); a kind of the process for data transformation. In a general way, a scientist use frequncy band 30[㎒]~l[㎓] to applied field. If we are measured high frequency band, we will need to a high capacity hardware. Also a antenna has a fault on atmospheric phenomena, outside environment and the like. In this paper We proposed new method for detecting electric equipment faulty state using only electric voltage which is generally measured in the electric and electronic field. It is called the Partition-FFT The analytic method is this first divide measured voltage waves into equal parts, second each deal with give effect to the FFT, finally each results deal with a graphic method and gather graphic. We are compare Partition-FFT with discharge form by tracking tester. As the result it demonstrated that the Partition-FFT is applicable.

Efficient Partitioning of Matched Filter for Long Pulse in Active Sonar Application (능동 소나에서 시간적으로 긴 펄스에 대한 정합 필터의 효율적인 분할 기법)

  • Shin, Donghoon;Kim, Jin Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.262-267
    • /
    • 2014
  • Recently, long pulses are transmitted for target detection in active sonar application. Matched filtering implemented by simple convolution algorithm, requires massive computational power for long replica. The computational loads are reduced significantly by implementing the convolution in the frequency domain with overlap add method, but the performance degrades for specified input/output system delay which constrains the size of FFT function. For performance improvement, the replica could be partitioned into uniform blocks (FDL) by re-using IFFT operations, or variable blocks of increasing length (MC) by using the largest possible blocks to calculate the convolution. In this paper, by combining the strong points of the two methods, we propose a new filter partition structure that allows for further optimization of the previous two methods.