• 제목/요약/키워드: Particle size measurement

검색결과 441건 처리시간 0.028초

겨울철 서울 내부순환로 도로상 초미세입자 오염의 공간분포 특징 (Spatial Distributions of On-road Ultrafine Particle Number Concentration on Naebu Express Way in Seoul during Winter Season)

  • 우대광;이승복;이승재;김진영;진현철;김태성;배귀남
    • 한국대기환경학회지
    • /
    • 제29권1호
    • /
    • pp.10-26
    • /
    • 2013
  • To understand the traffic emissions with high temporal and spatial resolutions on road, a mobile laboratory was developed. The objective of this study is to characterize on-road air pollution on Naebu express way surrounding the northern area of Seoul, Korea. We measured the number concentration of ultrafine particles larger than 5 nm and particle size distribution using a condensation particle counter and a fast mobility particle sizer, respectively on 3, 7, and 8 December 2009. The average ultrafine particle number concentration on the Naebu express way excluding tunnels was 126,000 particles/$cm^3$ and 4.2 times higher than that on internal road at Korea Institute of Science and Technology in Seoul, and more than twice higher than that measured on and at the arterial roads of Seoul in previous studies. The maximum ultrafine particle number concentration was observed at the tunnel sections. It was 232,000 particles/$cm^3$ and 1.8 times higher than average ultrafine particle number concentration for the other sections on Naebu express way. The ultrafine particle number concentration on the wider roads with higher traffic volume along the Han River was similar to that in the residential section, probably because of enhanced dilution effect in widely open environment. The size distribution of particles on the Naebu express way was highly fluctuated for a short duration. Ultrafine particles measured at the tunnel showed a bimodal size distribution with mode diameters of ~10 nm and ~50 nm. At the Han riverside section, ~10 nm particles appeared significantly compared with size distribution at the tunnel. This on-road measurement approach can be utilized to manage vehicle-related air pollution in urban area.

공기 중 농약 비산의 측정을 위한 광학 입자 측정기의 적용성 평가 (Applicability of Optical Particle Counters for Measurement of Airborne Pesticide Spray Drift)

  • 김락우;홍세운
    • 한국농공학회논문집
    • /
    • 제61권5호
    • /
    • pp.79-87
    • /
    • 2019
  • With desires for safe food, there is growing concern that pesticide spray drift will expose people, plants, and the environment to pesticide residue and potential negative effects thereof. For highly efficient, safe spray application, technologies for measuring the spray drift should be developed and improved with some urgency. This study investigated the applicability of two optical particle counters (OPCs), which are mostly used to measure airborne particle mass concentration, for measurement of airborne pesticide spray drift. Experiments were conducted in a controlled laboratory and an ash tree orchard to evaluate the handiness and accuracy of two OPCs, OPC 1 and OPC 2. The experimental results indicated that the OPC 1 was better applicable to the measurement of spray drift in the field while the use of the OPC 2 was limited due to its narrow range of measurable droplet sizes. The readings of the OPC 1 produced highly accurate results ($R^2=0.9637$) compared to the actual spray drift. For better application of OPCs, this study suggests the OPCs should be positioned properly to inhale spray droplets of the appropriate size and concentration.

해상도 3차원 상호상관 Volume PIV 시스템 개발 및 적용 (Development and Application of High-resolution 3-D Volume PIV System by Cross-Correlation)

  • 김미영;최장운;이현;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.507-510
    • /
    • 2002
  • An algorithm of 3-D particle image velocimetry(3D-PIV) was developed for the measurement of 3-D velocity Held of complex flows. The measurement system consists of two or three CCD camera and one RGB image grabber. Flows size is $1500{\times}100{\times}180(mm)$, particle is Nylon12(1mm) and illuminator is Hollogen type lamp(100w). The stereo photogrammetry is adopted for the three dimensional geometrical mesurement of tracer particle. For the stereo-pair matching, the camera parameters should be decide in advance by a camera calibration. Camera parameter calculation equation is collinearity equation. In order to calculate the particle 3-D position based on the stereo photograrnrnetry, the eleven parameters of each camera should be obtained by the calibration of the camera. Epipolar line is used for stereo pair matching. The 3-D position of particle is calculated from the three camera parameters, centers of projection of the three cameras, and photographic coordinates of a particle, which is based on the collinear condition. To find velocity vector used 3-D position data of the first frame and the second frame. To extract error vector applied continuity equation. This study developed of various 3D-PIV animation technique.

  • PDF

이미지프로세싱 기법을 이용한 액적크기 측정 (Droplet size measurement using image processing method)

  • 임병직;정기훈;길태옥;윤영빈
    • 한국가시화정보학회지
    • /
    • 제2권1호
    • /
    • pp.25-31
    • /
    • 2004
  • Droplet size is one of the most important parameter which controls the performance of the combustion system using liquid fuel or oxidizer. Droplet formation and its size are mainly affected by the injection velocity and ambient gas density. Recently, droplet size measurement was conducted by PDPA or Malvern particle analyzer using laser light. But at this paper image processing method was developed to measure droplet size. And its validation was investigated with reticle.

  • PDF

국내 원산지별 고춧가루의 매운맛 비파괴 측정기술 개발 (Development of non-destructive pungency measurement technique for red-pepper powder produced in different domestic origins)

  • 모창연;이강진;임종국;강석원;이현동;조병관
    • 농업과학연구
    • /
    • 제39권4호
    • /
    • pp.603-612
    • /
    • 2012
  • In this research, the feasibility of non-destructive measurement technique of pungency measurement was investigated for the red-pepper powders produced in different domestic areas in South Korea. The near-infrared absorption spectra in the range of 1100 nm~2300 nm was used to measure capsaicinoids content in red-pepper powders by using a NIR spectroscopy equipped with Acousto-optic tunable filters (AOTF). Fourth three different red-pepper powders from 14 different locations were collected and separated in three different particle size (below 0.425 mm, 0.425~0.71 mm, 0.71~1.4 mm) for the spectral measurements. The partial least square regression (PLSR) models to predict the capsaicinoids content depends on particle size were developed with the measured spectra. The determinant coefficients and standard errors of the developed models for the red-pepper powders of below 0.425 mm, 0.425~0.71 mm, and 0.71~1.4 mm were in the range of 0.859~0.887 and 12.90~12.99 mg/100 g, respectively. The PLS model with the pretreatment of Standard Normal Variate (SNV) for the red-pepper powders below 1.4 mm particle size showed the best performance with the determinant coefficient of 0.844 and the standard error of 14.63 mg/100 g.

광학입자센서 내 유동장과 측정영역이 측정효율에 미치는 영향 (Effect of Flow Field and Detection Volume in the Optical Particle Sensor on the Detection Efficiency)

  • 김영길;전기수;김태성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3162-3167
    • /
    • 2007
  • The OPS (Optical Particle Sensor) using light scattering from the particles (real-time measurement without physical contact to the particles) can be used for cleanroom or atmospheric environment monitoring. For particles smaller than 300 nm, the detection efficiency becomes lower as scattered light decreases with particle size. To obtain higher detection efficiency with small particles, the flow field in particle chamber and the detection volume should be designed optimally to achieve maximum scattered light from the particles. In this study, a commercial computational fluid dynamics software FLUENT was used to simulate the gas flow field and particle trajectories with various optical chamber designs for 300 nm PSL particle. For estimation of laser viewing volume, we used a commercial computational optical design program ZEMAX. The results will be a great help in the development of OPS which can measure small particles with higher detection efficiency.

  • PDF

라텍스 입자구조가 필름형성 및 필름물성에 미치는 영향 (III);모델 복합라텍스 입자의 필름물성 (Effect of Latex Particle Morphology on the Film Formation and Film Properties of Acrylic Coatings (III);Film Properties of Model Composite Latex)

  • 주인호;변자훈;우종표
    • 한국응용과학기술학회지
    • /
    • 제21권3호
    • /
    • pp.259-266
    • /
    • 2004
  • Film properties of monodispersed model composite latexes with particle size of 190 nm, which consist of n-butyl acrylate as a soft phase monomer and methyl methacrylate as a hard phase monomer with different morphology was examined. Five different types of model latexes were used in this study such as random copolymer particle, soft-core/hard-shell particle, hard-core/soft-shell particle, gradient type particle, and mixed type particle. Tensile strength and tensile elongation at break of final films were evaluated. Those properties can be interpreted in terms of PBA/PMMA phase ratio and their morphology. The interfacial adhesion strength was also evaluated using $180^{\circ}$ peel strength measurement and cross hatch cutting test.

Secondary Electron Emission Characteristics of Functional Layer in AC-PDP

  • Son, Chang-Gil;Han, Young-Gyu;Kim, Yong-Hee;Cho, Byeong-Seong;Hong, Young-Jun;Song, Ki-Baek;Bae, Young-Joo;Kim, In-Tae;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.736-739
    • /
    • 2009
  • We have studied that the secondary electron emission characteristics of functional layers which have different kinds of MgO sub-micrometer size powder in AC-PDP. We used cathodoluminescence(CL) and gamma focused ion beam (${\gamma}$-FIB) system for measurement of secondary electron emission characteristics. Also we made 6 inch test panel which applied functional layers for evaluation of discharge characteristics.

  • PDF

Measurement of the Particle Current Changes Associated with the Flatness of Deflector Mesh Surface in Particle Beam Mass Spectrometer System

  • Kim, Dongbin;Kim, TaeWan;Jin, Yinhua;Mun, Jihun;Lim, In-Tae;Kim, Ju-Hwang;Kim, Taesung;Kang, Sang-Woo
    • Applied Science and Convergence Technology
    • /
    • 제25권2호
    • /
    • pp.25-27
    • /
    • 2016
  • The surface flatness of metal meshes in a deflector of particle beam mass spectrometer (PBMS) required ideally flat, and this can specify the particle trajectories which goes through the detector. In this research, charged particle current was measured using the different surface roughness deflectors. NaCl particles were generated monodispersed in its size by using differential mobility analyzer and the whole processes were followed the way calibrating PBMS. The results indicate that the mesh surface morphology in the deflector can affect to the particle size and the concentration errors, and sensitivity of PBMS.