• Title/Summary/Keyword: Particle separation

Search Result 480, Processing Time 0.024 seconds

Direct-Current Dielectrophoretic Motions of a Pair of Particles due to Interactions with a Nearby Nonconducting Wall (비전도성 벽과의 상호작용에 따른 한 쌍 입자의 직류 유전영동 운동)

  • Kang, Sangmo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.805-815
    • /
    • 2015
  • The present study numerically investigated two-dimensional dielectrophoretic motions of a pair of particles suspended freely in a viscous fluid, interacting with a nearby nonconducting planar wall, under an external uniform electric field. The results show that the motions depend strongly on the set of two electric conductivity signs and the particles-wall separation gap. When both particles have the same sign, they revolve and finally align parallel to the electric field. In contrast, with different signs, they revolve in the opposite direction and finally align perpendicular to the field. Simultaneously, they are repelled to move farther away from the wall regardless of their conductivity set. With further separation from the wall, the particles-wall interaction effect diminishes and tthe particle-particle effect dominates.

The Manufacturing Characteristics of Magnesium Chloride Emulsion by Different Rotational Speed of Homomixer as Soybean Curd Coagulant (두부응고제로서 Homomixer 회전속도를 달리한 염화마그네슘유화물의 제조특성)

  • Hong, Seung-Seok;Park, Won-Jong;Joung, Kyung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1252-1257
    • /
    • 2013
  • This study was used homomixer as one of the manufacturing method to establish optimal manufacturing condition with magnesium chloride emulsion as coagulant. The more rotational speed of homomixer was fast, the more particle size of magnesium chloride emulsion was minute. The particle size was distributed between 1 and $5{\mu}m$. The more minute particle size of emulsion had an effect on increasing viscosity of emulsion and delay of oil phase separation during storage period, so the quality of magnesium chloride emulsion had correlation with dispersed phase particle size. After all the experiments, when manufacturing magnesium chloride emulsion, it used more than 10,000 rpm of rotational speed of homomixer, it showed the best result as coagulant according to the state of texture and the water separation ratio of soybean curd.

Separation characteristics of particles in a self-rotating type centrifugal oil purifier

  • Pyo, Young-Seok;Jung, Ho-Yun;Choi, Yoon-Hwan;Doh, Deog-Hee;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.147-153
    • /
    • 2014
  • The centrifugal oil purifier is used in an engine for lubrication and to remove impurities. The momentum needed for the rotation of the cylindrical chamber is obtained by jet injections. An impure particle in the oil is separated by the centrifugal forces moving to the inner wall of the rotating cylindrical chamber body. The dust particles are eliminated when the particles are absorbed onto the surface of the inner wall of the chamber body. The flow characteristics and the physical behaviors of particles in this centrifugal oil purifier were investigated numerically and the filtration efficiencies was evaluated. For calculations, a commercial code is used and the SST (Shear Stress Transport) turbulence model has been adopted. The MFR (Multi Frames of Reference) method is introduced to consider the rotating effect of the flows. Under various variables, such as particle size, particle density and rotating speed, the filtration efficiencies are evaluated. It has been verified that the filtration efficiency is increased with the increments in the particle size, the particle density and the rotating speed of the cylindrical chamber.

Effects of Particle Size of Dry Water on Fire Extinguishing Performance (드라이워터의 입자크기가 소화성능에 미치는 영향)

  • Lee, Eungwoo;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.28-35
    • /
    • 2019
  • Dry water is a core-shell structured powder which comprises a very fine water core covered with hydrophobic silica particles. Recently, the dry water has attracted attention as a new type of fire extinguishing agents. However, characteristics of the dry water as a fire extinguishing agent have not been revealed until now. To our best knowledge, this is the first work to uncover effects of particle size of the dry water on the fire extinguishing performance. Pristine dry water, which has heterogeneous particle size distribution, was carefully separated by sieving method into three fractions which were a small size (ca. $110{\mu}m$) fraction, a medium size (ca. $220{\mu}m$) fraction and a large size (ca. $400{\mu}m$) fraction. Microscopic observations confirmed the effective separation of dry water's particle size. In extinguishing tests of wood cribs fire, the medium size dry water showed most excellent fire extinguishing performance, as compared to other dry waters having small (ca. $110{\mu}m$) and large (ca. $400{\mu}m$) particle size. The good performance of the medium size (ca. $220{\mu}m$) dry water may be attributed to the balance between cooling effect of the water core and smothering effect of the silica particles. It is also revealed that small size dry water has poor flowability than large size dry water.

A PIV Study of Flow Patterns Over Stationary and Pitch-Oscillating Airfoils with Blowing Jet

  • Lee, Ki-Young;Chung, Hyoung-Seog;Cho, Dong-Hyun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.1
    • /
    • pp.111-120
    • /
    • 2008
  • A particle image velocimetry (PIV) technique was employed to investigate the effects of blowing jet on the flow characteristics over stationary and pitch-oscillating airfoils. The Reynolds number was $7.84{\times}10^5$ based on the chord length. It was found that for stationary airfoil cases, continuous and pulsating blowing jets successfully reduced separated wake region at high angles of attack. A comparison study of two different types of jet blowing indicated that pulsating jet is more effective than continuous jet for flow separation control. Pulsating leading-edge blowing postpones flow separation and increased stall angle of attack by $2^{\circ}{\sim}3^{\circ}$. For pitch-oscillating airfoil cases, the PIV results showed that blowing jet efficiently delays the separation onset point during pitch-up stroke, whereas it does not prevent flow separation during pitch-down stroke, even at angles of attack smaller than static ones.

Separation of Selenite from Inorganic Selenium Ions using TiO2 Magnetic Nanoparticles

  • Kim, Jongmin;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3362-3366
    • /
    • 2013
  • A simple and quick separation technique for selenite in natural water was developed using $TiO_2$@$SiO_2/Fe_3O_4$ nanoparticles. For the synthesis of nanoparticles, a polymer-assisted sol-gel method using hydroxypropyl cellulose (HPC) was developed to control particle dispersion in the synthetic procedure. In addition, titanium butoxide (TBT) precursor, instead of the typical titanium tetra isopropoxide, was used for the formation of the $TiO_2$ shell. The synthesized nanoparticles were used to separate selenite ($Se^{4+}$) in the presence of $Se^{6+}$ or selenium anions for the photocatalytic reduction to $Se^0$ atom on the $TiO_2$ shell, followed by magnetic separation using $Fe_3O_4$ nanoparticles. The reduction efficiency of the photocatalytic reaction was 81.4% at a UV power of 6W for 3 h with a dark adsorption of 17.5% to the nanoparticles, as determined by inductively coupled plasma-mass spectrometry (ICP-MS). The developed separation method can be used for the speciation and preconcentration of selenium cations in environmental and biological analysis.

Particle Separation Characteristics and Harvesting Efficiency of Spirulina platensis Using Micro-bubble (미세기포를 이용한 Spirulina platensis의 입자 부상분리 특성 및 수거효율)

  • Gwak, Gyu-Dong;Kim, Mi-Sug;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.621-629
    • /
    • 2013
  • Since algae had been issued an environmental problem, water blooms, deepened due to increase of retention water basin in Korea as well as a biomass resource for producing biofuel, this study conducted a series of experiments for Spirulina platensis using the flotation process with micro-bubble. To elevate utilization of collected-algae, this study focused on omitting or minimizing coagulant's doses as changing a cultivation period and condition affected on physical property change of algae. Two coagulants, PAC and Chitosan, were used to test the collecting rate of algae and the result found no difference between two rates. For flotation experiments without adding the coagulant, dried algae weight (passing 14 days after cultivation for 20 days) detected high separation efficiency 98.2 % and it (passing 7 days after long-term cultivation for 28 days) presented good separation efficiency 91.9 %. Chlorophyll's separation efficiency showed a similar tendency with the case of the dried algae weight. In endogeny conditions, a light source and a carbon source were not considerably affected on the flotation separation efficiency. Thus, this study confirms that algae biomass may be collected without the coagulant during the endogeny condition period after enough cultivation time, 3 weeks.

Microfluidic cell sizing using hydrophoretic size-based separation (유체영동 기반의 입자분리현상을 이용한 세포 크기 측정방법)

  • Choi, Sung-Young;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.245-249
    • /
    • 2008
  • This paper presents a microfluidic cell sizing method using hydrophoretic size-based separation. By exploiting slanted obstacles in a microchannel, we can generate a lateral pressure gradient so that microparticles can be deflected and arranged along lateral flows induced by the gradient. Using such movement of particles, we discriminated 8 to 15 μm-sized beads. We measured the size of U937 cells by comparing the hydrophoretic response of the cells to those of the size-standard beads whose diameters are known. Due to its simple design and fabrication, the sizing method can be easily integrated with other microfluidic components such as cell culture chambers conducting on-chip sizing and sorting.

Nano-scale Shell in Phase Separating Gd-Ti-Al-Co Metallic Glass

  • Chang, Hye Jung;Park, Eun Soo;Kim, Do Hyang
    • Applied Microscopy
    • /
    • v.43 no.2
    • /
    • pp.98-101
    • /
    • 2013
  • In the present study, formation of yard and shell has been investigated in as-melt-spun $Gd_{30}Ti_{25}Al_{25}Co_{20}$ alloy using a variety of transmission electron microscopy techniques. The phase separation during cooling leads to the formation of the microstructure consisting of amorphous droplets with different size scales embedded in the amorphous matrix. Due to the interdiffusion at the interface after the first-step phase separation, ~50 nm-thick yard develops on the surface of the primary droplet particle. Due to the critical wetting phenomenon, ~5 nm thickness shell enveloping the droplet forms. The sell is enriched in Co and Ti, implying that the composition is close to that of the droplet.

Treatment of ASR from End-of-Life Vehicles by Air and Gravimetric Separation (廢自動車 ASR의 風力 및 比中選別에 의한 處理 硏究)

  • Lee, Hwa-Young;Oh, Jong-Kee
    • Resources Recycling
    • /
    • v.14 no.2
    • /
    • pp.3-9
    • /
    • 2005
  • A study on the air and gravity separation has been performed for the removal of chlorine containing materials from ASR of end-of-life vehicles. The gravity separation was also conducted on waste plastics collected from ASR. In this work, ASR were previously shredded to pass through 8 mm sieve prior to separation tests and the gravity separation of waste plastics was conducted for three different particle sizes. The two-stage air classification was conducted with the range of air flow rate of 9~20 M$^3$/hr at first stage and 25~34 M$^3$/hr at second stage, respectively. The fraction of overflow product was remarkably increased in the 2nd stage air classification because of high air flow rate while that of underflow product obtained from 1st stage air classification was found to be 62~66%. From the results of gravity separation on waste plastics, it was also found that the amount of the float product was much greater than sink product. It is believed that the gravity separation may be used very efficiently for the removal of calorine bearing materials from waste plastics.