• Title/Summary/Keyword: Particle diameter distribution

Search Result 354, Processing Time 0.024 seconds

Size Measurement of Radioactive Aerosol Particles in Intense Radiation Fields Using Wire Screens and Imaging Plates

  • Oki, Yuichi;Tanaka, Toru;Takamiya, Koichi;Osada, Naoyuki;Nitta, Shinnosuke;Ishi, Yoshihiro;Uesugi, Tomonori;Kuriyama, Yasutoshi;Sakamoto, Masaaki;Ohtsuki, Tsutomu
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.216-221
    • /
    • 2016
  • Background: Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. Materials and Methods: A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of $^{11}C$-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. Results and Discussion: The size distribution for $^{11}C$-bearing aerosol particles was found to be ca. $70{\mu}m$ in geometric mean diameter. The size was similar to that for $^7Be$-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. Conclusion: The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

Drying Characteristics of Rotary Dryer with Disintegrator (교반기를 부착한 회전건조기의 건조특성)

  • Chun, W.P.;Lee, K.W.;Park, K.H.;Lee, K.J.;Kim, D.K.;Kim, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.133-138
    • /
    • 2001
  • In this paper, we have investigated the drying characteristics of waste sludge in a rotary dryer equipped with disintegration device. The sludge samples($moisture\;contents\;:\;70{\sim}85%\;W.B.$) used in the experiment were mainly a soybean and an alcohol fermentation sludges in food industry, or sewage sludge. It was studied by measuring the change of moisture contents that the shaft speed($operating\;range\;:\;100{\sim}250rpm$) affected on the drying rate and the particle size distribution of the dried solid. The dried granular products of the diameter of 1 to 5mm are obtained from sludge materials. In the results, as the increased of shaft speed, the particle size and the moisture contents of dried solid was decreased, and the retention time was increased.

  • PDF

Spraying Status Evaluation of the Electro-static Sprayer Using Computer Image Processing (컴퓨터 영상처리를 이용한 정전분무기의 분무상태 평가)

  • Hwang, H.;Cho, S. I.;Cho, D. Y.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.391-398
    • /
    • 1999
  • The spraying status of the electrostatic sprayer was evaluated by processing surface spraying images of the natural leaves. Water solution of the fluorescent material was used as a spray medium. The image of the lights reflected by fluorescent droplets was captured under UV light using a color CCD camera. Coverage rate, particle density, and the size distribution of particles were analyzed from the surface images of leaves under various spraying conditions such as spraying nozzle angle and object distance. Spraying characteristics of the electrostatic sprayer was evaluated in comparison with the conventional one. In a case of electrostatic sprayer, coverage rate and particle density increased by the average of 1.57times and 1.01times respectively under various nozzle angles and distances. The number of particle under the diameter of 50 ${\mu}{\textrm}{m}$ also increased significantly.

  • PDF

Physicochemical Evaluation of Oil in Water Microemulsions (수중유형 마이크로에멀젼의 물리화학적 평가)

  • Chung, Myung-Hwa;Jheong, Yeoub;Jheong, Dae-Sik;Kwon, Jong-Won;Yang, Joong-Ik;Min, Shin-Hong
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.1
    • /
    • pp.9-13
    • /
    • 1988
  • Physicochemical properties of oil in water microemulsions containing soybean oil and egg phosphatide were observed for 3 weeks under the storage condition of $4^{\circ}C$ refrigerator. Changes in major fatty acid content, particle size distribution, rheogram, acid value and pH value were measured by gas chromatograph, laser particle sizer, Coulter counter and rheometer. From above experiments following conclusions were obtained; 1) Mean particle diameter was shifted from 240 to 266mm. 2) No significant changes were observed in the content of major fatty acids of soybean oil, rheogram, acid value and pH value.

  • PDF

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

Microstructure and Synthesis of Ag Spot-coated Cu Nanopowders by Hydrothermal-attachment Method using Ag Colloid (수열흡착법을 이용한 은 점코팅된 구리 나노분말의 합성과 미세조직)

  • Kim, Hyeong-Chul;Han, Jae-Kil
    • Journal of Powder Materials
    • /
    • v.18 no.6
    • /
    • pp.546-551
    • /
    • 2011
  • Ag spot-coated Cu nanopowders were synthesized by a hydrothermal-attachment method (HA) using oleic acid capped Ag hydrosol. Cu nano powders were synthesized by pulsed wire exploding method using 0.4 mm in diameter of Cu wire (purity 99.9%). Synthesized Cu nano powders are seen with comparatively spherical shape having range in 50 nm to 150 nm in diameter. The oleic acid capped Ag hydrosol was synthesized by the precipitation-redispersion method. Oleic acid capped Ag nano particles showed the narrow size distribution and their particle size were less than 20 nm in diameter. In the case of nano Ag-spot coated Cu powders, nanosized Ag particles were adhered in the copper surface by HAA method. The components of C, O and Ag were distributed on the surface of copper powder.

A Study of Spray Characteristics of the Rotating Fuel Nozzle with Orifice Diameters (회전연료노즐의 오리피스직경에 따른 분사특성연구)

  • Lee, Mae-Hoon;Jang, Seong-Ho;Lee, Dong-Hun;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.258-263
    • /
    • 2010
  • An experimental study was performed to understand spray characteristics of the V type rotating fuel nozzle with orifice diameters by using high speed rotational system. The experimental apparatus consist of a high speed rotational system, fuel injection system and acrylic case. The droplet size and velocity were measured by PDPA(Phase Doppler Particle Analyzer) and spray was visualized by using Nd-Yag laser-based flash photography. From the test results, droplet diameters are reduced with increasing orifice diameter and the optimum injection orifice diameter is 2.6 mm. When increasing orifice diameter over than 2.6 mm, droplet diameter is not decreased with increasing orifice diameter. This is due to the irregular distribution of the liquid sheet around the inner surface of injection orifice.

  • PDF

Alum Floc Attachment in Granular Media Filtration (입상여과에서 액반플럭의 부착)

  • Kim, Jinkeun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.625-630
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and alum coagulation was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration when zeta potential of particles and collectors are both negative. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPDs of the effluent moved from more positive to less positive when the surface charge of particles was positive and this result was thought to be caused by ion transfer between particles and collectors.

Chemical Transformation of Individual Asian Dust Particles Estimated by the Novel Double Detector System of Micro-PIXE

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.106-114
    • /
    • 2010
  • By the application of novel double detector system of micro-PIXE that can detect light elements (Z<14), we made an attempt to provide a thorough discussion on the aging processes of Asian dust (hereafter called "AD") particle by reaction with sea-slat. The elemental spectra and maps obtained from the microbeam radiation of micro-PIXE to individual AD particles were useful for fractionating AD particles into both internally and externally mixed particles. A spatial distribution of elements in a minute domain of single particle obtained by scanning the microbeam irradiation enabled us not only to estimate the chemical mixing state of individual AD particles but also to presume their aging processes in both ambient air and cloud. By calculating the normalized micro-PIXE net count of elements, it was possible to classify individual AD particles into three distinct groups (i.e., (1) Aging type 1: AD particle coated by the gaseous Cl evaporated by the reaction between artificial acids and sea salt; (2) Aging type 2: AD particle mixed with sea salt but no additional reaction with artificial acids; and (3) Non-aged type) A relatively high transformation rate (63.3-75.9%) was shown in large particles (greater than $5.1\;{\mu}m$ in diameter).

Measurement of Particle Deposition Velocity toward a Horizontal Semiconductor Wafer Using a Wafer Surface Scanner (Wafer Surface Scanner를 이용한 반도체 웨이퍼상의 입자 침착속도의 측정)

  • Bae, G.N.;Park, S.O.;Lee, C.S.;Myong, H.K.;Shin, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.130-140
    • /
    • 1993
  • Average particle deposition velocity toward a horizontal semiconductor wafer in vertical airflow is measured by a wafer surface scanner(PMS SAS-3600). Use of wafer surface scanner requires very short exposure time normally ranging from 10 to 30 minutes, and hence makes repetition of experiment much easier. Polystyrene latex (PSL) spheres of diameter between 0.2 and $1.0{\mu}m$ are used. The present range of particle sizes is very important in controlling particle deposition on a wafer surface in industrial applications. For the present experiment, convection, diffusion, and sedimentation comprise important agents for deposition mechanisms. To investigate confidence interval of experimental data, mean and standard deviation of average deposition velocities are obtained from more than ten data set for each PSL sphere size. It is found that the distribution of mean of average deposition velocities from the measurement agrees well with the predictions of Liu and Ahn(1987) and Emi et al.(1989).

  • PDF