• 제목/요약/키워드: Particle Filters

검색결과 231건 처리시간 0.031초

성남시 대기정유분새중 호흡성 분여에서 중금속의 농도 및 입경분포 (The Heavy Metals and Size Distribution of Respirable Suspended Particulate Matter at Sungnam City)

  • 권우택;유영식
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.53-61
    • /
    • 1994
  • Sungnam city, as a major satellite town, is located in the southeast of Seoul. Atmospheric conditions are so stable that air pollutants from various emissions are tend to resist change because Sungnam city is located in the Namhansansung valley. The industrial distribution of Sungnam city are composed of various manufactories such as foods, fibers, chemicals, machinery and electronics etc. The heavy metal concentrations and size distribution are the most important parameters influencing among the way in which respirable suspended particulate matter interact with the human respiratory system. Respirable suspended particulate matter was collected on glass fiber filters from April 1993 to February 1994 according to particle size using Anderson sampler during 10 days per month at Sungnam city. 6 heavy metals, Fe, Zn, Pb Mn, Cu and Cd, were analyzed by particle size with atomic absorption spectrophotometry . The results could be summarized as follows: 1. The annual arithmetic mean concentration of total suspended particulate was 116.3$\mu $g/m$^{3}$ m', seasonal variation was the highest in spring season(196.5$\mu $g/m$^{3}$) and the lowest in Summer Season(72.9$\mu $g/m$^{3}$). 2. The ratio of airborne particulate concentrations respirable to nonrepairable( Res/Non- Res) of annual arithmetic mean value was 5.8'1, seasonal variation was highest in the spring season(6.3 : 1) and lowest in the summer season(4.6 : 1). 3. During the spring season the shape of the size distribution was trimodal which showed peaks at 3 size groups, which were below of 0.43$\mu $m, 3.3∼4.7$\mu $m and above of 11.0$\mu $g/m$^{3}$ respectively. 4. Respirable suspended particulate matter concentrations of Zn, Pb Cu and Cd were the highest in below of 0.43$\mu $m as follows; 0.517$\mu $g/m$^{3}$, 0.411 $\mu $g/m$^{3}$, 0.062$\mu $g/m$^{3}$ and 0.0310$\mu $g/m$^{3}$ , respectively, Fe and Mn were the highest in the particle size range of 4.7 ∼ 7.0$\mu $m as follows; 2.504$\mu $g/m$^{3}$ and 0.095$\mu $g/m$^{3}$, respectively. 5. The Pt Cd, Zn, Cu, Fe and Mn concentrations of annual arithmetic mean value respirable to non- respirable( Res/Non- Res ) were 33.65, 19.27, 17.74, 10.54, 3.20 and 5.20, respectively.

  • PDF

클러터가 존재하는 환경에서의 ITS 필터를 이용한 재진입 발사체의 낙하지점 추정 기법 연구 (A Study on Impact Point Prediction of a Reentry Vehicle using Integrated Track Splitting Filters in a Cluttered Environment)

  • 문경록;김태한;송택렬
    • 한국항공우주학회지
    • /
    • 제40권1호
    • /
    • pp.23-34
    • /
    • 2012
  • 우주 발사체는 치밀한 비행 계획에 따라 사전에 결정된 경로를 비행하도록 설계된다. 그러나 비정상으로 추력이 종료되거나 계획된 비행경로를 이탈한 경우, 또는 자유 낙하 중인 대기권 재진입 발사체에 대한 추적 과정에서 추적 센서의 측정이 불가하게 된 경우 등에는 별도의 추적 장비를 이용한 추적 또는 신속한 낙하지점 추정이 필요하다. 본 논문에서는 클러터 환경에서 무추력 탄도 비행 중인 발사체에 대한 위치 정보를 획득하고 트랙을 생성 및 유지하기 위하여 Integrated Track Splitting(ITS) 알고리듬과 Extended Kalman Filter(EKF)를 결합한 ITS-EKF 알고리듬 적용을 제안한다. 따라서 대기권 재진입 발사체에 대하여 ITS-EKF 알고리듬을 적용한 시뮬레이션을 통해 추적 성능 확인 및 지상 낙하지점을 추정한다. ITS-EKF 알고리듬 적용 결과의 적절성을 확인하기 위하여 ITS와 Particle Filter를 결합한 ITS-PF 알고리듬을 적용하여 구한 추적 성능 및 낙하지점 분포 결과와 비교하여 제시된 알고리듬이 효과적인 실시간 On-line 낙하지점 추정에 사용이 가능함을 확인한다.

IMU/Range 시스템의 필터링기법별 위치정확도 비교 연구 (A Comparison on the Positioning Accuracy from Different Filtering Strategies in IMU/Ranging System)

  • 권재현;이종기
    • 한국측량학회지
    • /
    • 제26권3호
    • /
    • pp.263-273
    • /
    • 2008
  • 위치 센서를 기반으로 하는 디지털 지도의 구축과 이로부터의 도로의 추출과 같은 생성물의 정확도는 센서의 위치 정확도에 좌우되며, 센서의 위치결정을 위하여 GPS, 토탈스테이션, 레이저거리계 등 다양한 거리측정시스템들이 사용되어 왔다. 일반적으로 거리측정시스템들은 주위 다양한 환경에 따라 신호단절 및 감퇴의 문제점과 낮은 시간해상도를 가지고 있다. 이러한 한계를 극복하기 위해 관성 장치와 같은 자동 항법 장치를 이용하여 상호 보완 및 통합하여 IMU/Range 통합 시스템을 구성 할 수 있다. 본 논문에서는 항법 및 측지분야에서 성공적으로 사용되어 왔던 선형필터인 확장 칼만 필터(Extended Kalman Filter, EKF)의 문제점을 지적하고, 비선형 변환과 선택된 시그마 포인트를 이용한 시그마 포인트 칼만 필터(sigma point Kalman filter, SPKF)와 비가우시안 가정과 샘플링 방식의 파티클 필터(Particle filter, PF) 등 두가지 비선형 필터를 구현하고, 시뮬레이션을 수행하여 그 결과를 확장 칼만 필터의 경우와 비교하였다. 시뮬레이션의 거리측정시스템으로 GPS와 토탈스테이션이 사용되었고 IMU의 경우, 정밀도 레벨에 따른 일반적인 3가지 센서(IMU400C, HG1700, LN100)가 선택되었다. 모든 IMU와 거리측정시스템에 대해서 샘플링 기반의 비선형 필터인 SPKF와 PF가 EKF에 비해 통계 결과에서 향상된 위치 결과를 보여 주었으며 특히 거리측정시스템의 갱신간격이 길어질수록(1초$\rightarrow$5초) 비선형 필터의 우수성이 나타났다. 따라서 저가형 위치센서의 경우, 비선형 필터를 적용하여 센서 위치의 정확도를 높일 수 있는 것으로 판단된다.

지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교 (Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2)

  • 이건희;김상복;박인용;홍기정;이예완;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

하수처리수 재이용을 위한 가압식 규조토 여과의 처리성능평가 (Characteristics of Filtration Treatment Using Diatomite Filter Aids for Sewage Water Reuse)

  • 임병란;김희서;고연실;김현갑;김종학;이태진
    • 한국물환경학회지
    • /
    • 제35권2호
    • /
    • pp.145-151
    • /
    • 2019
  • The purpose of this study was to investigate treatment characteristics of diatomite filtration, that would allow water recovery from biologically-treated effluent for reuse. Diatomite, Celpure 100, and acid clay were used as filter-aids, with a support filter manufactured from polyethylene (PE), and polypropylene (PP). This pre-coating process using diatomite filter-aids, is used in the filtration range of pressure filters, and has consistently provided high-quality separation. The results showed that variations in average removal efficiency of SS, and T-P from biologically treated effluent by the diatomite-coated PE filter, were approximately 82.2 ~ 88.9 % and 4.8 ~ 21.1 %, respectively. T-P treatment efficiency of the PP filter pre-coated with diatomite and $Celpure^{(R)}100$ at $57.64g/m^2$, was approximately $24{\pm}10%$ and $40{\pm}15%$ on average, respectively. Particle size distribution of secondary effluent varied from 0.05 to $200{\mu}m$, and $d_{50}$ value was $20.76{\mu}m$. The size distribution of particles in the diatomite filtrate ranged from 1.26 to $101.1{\mu}m$ when pre-coated with diatomite filter-aid, at a content of $57.64g/m^2$. Diatomite filter aids, i.e., the particles that form the pre-coating layer, capture very fine particles as well as macromolecules, owing to their complex structure with numerous fine microscopic pores, and surface properties. The filtration process using diatomite and $Celpure^{(R)}100$ as filter aids, has been successfully applied, to recover water from sewage for reuse. The disadvantage of the process, is that the particle size of the filter-aid is spent, because of pressurization.

항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가 (Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners)

  • 박현희;김세동;김성호;박승현
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

정전기분광분석방법에 의한 알파입자비적밀도의 이론적 계산연구 (Theoretical Calculation on Alpha Track Density by Using an Electrostatic Ion Spectrometer)

  • 윤석철;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제18권1호
    • /
    • pp.25-35
    • /
    • 1993
  • 알파비적밀도의 이론계산방법을 개발하기 위하여 정전기방법을 이용한 분광계를 특별히 설계 제작하였다. 이 정전기분광계를 사용하여 라돈의 첫째딸핵종인 Po-218의 이온에 대해 $0.07{\sim}5.0cm^2/V\;sec$ 범위의 이동도스펙트럼을 측정하였다. 이 측정은 실리카겔, 활성탄, 분자구조의 시브필터를 통과한 탈입자가스를 사용하는 라돈쳄버내에서 수행되었다. 제작된 정전기분광계를 사용하여 쳄버내에서 새로 생성된 Po-218이온의 이동도는 $1.92cm^2/V\;s$인 것으로 측정되었다. 알파비적밀도의 이론적계산방법에 의해 얻어진 결과를 측정에 의해 얻어진 결과와 비교하였으며 측정된 스펙트럼에 관계된 불확실도를 분석하였다. 이론계산방법에 의해 얻어진 알파비적밀도와 측정된 값과의 차이에 대한 이유는 이론계산방법에서 이온의 라돈 쳄버에서의 벽제거효과를 고려하지 않았기 때문인 것으로 밝혀졌다.

  • PDF

중성자 방사화분석법과 Gent SFU 샘플러를 이용한 도시의 농촌지역의 대기분지($PM_{10}$)관측 연구 (Study on Airborne Particulate Matter ($PM_{10}$) Monitoring in Urban and Rural Area by Using Gent SFU Sampler and Instrumental Neutron Activation Analysis)

  • 정용삼;문종화;김선하;박광원;강상훈
    • 한국대기환경학회지
    • /
    • 제16권5호
    • /
    • pp.453-467
    • /
    • 2000
  • The aim of this research is to collect and characterize fine particles (FPM:$\leq$2.5${\mu}{\textrm}{m}$) and coarse particles (CPM: 2.5~10${\mu}{\textrm}{m}$) using a low volume air sampler provided by the IAEA, at urban (Taejon) and rural area(Wonju) for a period of about two years(April 1996 to May 1998) and to promote a use of nuclear analytical techniques for air pollution studies. For the collection of airborne particulate matter (PM(sub)10), the Gent stacked filter unit sampler and polycarbonate membrane filters were employed. The concentration of trace elements in collected APM samples were determined byu instrumental Neutron Activation Analysis. For validation of the analytical data, internal quality control were implemented by using both the comparison of the analytical results of standard reference materials(NIST SRM 1648) and interlaboratory comparison for proficiency test (NAT-3). The standard uncertainty was less than 15% and Z-score of two samples were within $\pm$1. The monitoring of (PM(sub)10) mass concentration and elemental concentrations were carried out weekly. The average mass concentration of (PM(sub)10) in urban and rural areas were 59.2$\pm$36.5$\mu\textrm{g}$/㎥ and 41.4$\pm$23.7$\mu\textrm{g}$/㎥, respectively. To investigate the emission source, the enrichment factors were calculated for the fine and coarse particle fractions at two sites, respectively and these values were classified for anthropogenic and soil origin elements.

  • PDF

초미세입자 제거를 위한 나노세라믹 필터의 성능 평가 (Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles)

  • 김종원;안영철;이병권;정현재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

미세입자(PM2.5)의 질산염 (NO3-) 휘발 특성 분석 -서울시 4개 측정지역을 중심으로- (Characteristics of Nitrate (NO3-) Volatilization from Fine Particles (PM2.5) at 4 Measurement Sites in Seoul)

  • 김유정;정성운;강충민;마영일;김수향;우정헌;선우영
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.613-621
    • /
    • 2008
  • The purpose of this study is to understand the impact that temperature and relative humidity have on the volatilization loss of particulate nitrate $(NO_3^-)$ from Teflon filters during measurements of ambient fine particles $(PM_{2.5})$. Fine particles $(d_p<2.5{\mu}m)$ were measured using an annular denuder system (ADS) at four representive areas in Seoul. The measurements were made during 28 different days at 24-hr sampling intervals from February 14 to October 15, 1997. In this study, nitrate losses. calculated by the ratio of nitrate on the nylon filter to their sum in both Teflon and nylon titters, varied seasonally in the following order: summer (45.5%) > spring (23.8%) > fall (20.6%) > winter (19.7%). The results showed strong correlations with temperature, but we did not observe any significant effects of relative humidity. However, we observed that both temperature and relative humidity influenced the ambient gas/particle nitrate ratio in a different case study using a denuder.