• 제목/요약/키워드: Particle Counter

검색결과 212건 처리시간 0.026초

열처리 조건에 따른 스피넬 $LiMn_2O_4$의 전기 화학적 특성 (Electrochemical Properties of Spinel $LiMn_2O_4$Synthesized at Various Sintering Condition)

  • 한태희;박종광;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제12권1호
    • /
    • pp.50-55
    • /
    • 1999
  • We have investigated the $LiMn_2O_4$system as an cathode material for lithium rechargeable batteries. $LiMn_2O_4$spinel oxides have been synthesized by a solid state methode. We varied sintering time at a fixed sintering temperature of 75$0^{\circ}C$. In order to investigate the electrochemical properties of prepared $LiMn_2O_4$we assembled three-electrode cells using the working electrode as active material and Li metal as the counter and reference electrodes. The electrolyte was 1 M LiPE$_{6}$-EC:DEC(1:1 by volume). The particle size of sample synthesized at 75$0^{\circ}C$ ranged about 60$\mu m$. The discharge capacity of a cell involving spinel $LiMn_2O_4$ increased with increasing sintering time.e.

  • PDF

Isotopic Analysis of NUSIMEP-6 Uranium Particles using SEM-TIMS

  • Park, Jong-Ho;Park, Sujin;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • 제4권3호
    • /
    • pp.51-54
    • /
    • 2013
  • Isotopic analysis using thermal ionization mass spectrometry coupled with scanning electron microscopy (SEM-TIMS) was performed to determine the isotopic ratios of uranium contained in micro-particles in the 6th Nuclear Signatures Interlaboratory Measurement Evaluation Programme (NUSIMEP-6) sample. Elemental analysis by energy dispersive X-ray spectroscopy (EDS) was conducted on uranium-bearing mirco-particles, which were transferred to rhenium filaments for TIMS loading using a micromanipulation system in a SEM. A multi-ion-counter system was utilized to detect the ion signals of the four isotopes of uranium simultaneously. The isotope ratios of uranium corrected by bracketing using a reference material showed excellent agreement with the certified values. The measurement accuracy for $n(^{234}U)/n(^{238}U)$ and (b) $n(^{235}U)/n(^{238}U)$ was 10% and 1%, respectively, which met the requirements for qalification for the NetWork of Analytical Laboratories (NWAL).

X線螢光分析에 依한 珪酸鹽鑛物의 分析 (The X-Ray Fluorescent Spectrographic Analysis of Silicate Minerals)

  • 김찬국;상기남;김황암
    • 대한화학회지
    • /
    • 제13권1호
    • /
    • pp.49-55
    • /
    • 1969
  • 螢光X線을 利用하여 珪酸鹽鑛物中의 主成分인 $SiO_2$, $Al_2O_3$, $Fe_2O_3$, CaO, MgO 및 $K_2O$를 迅速히 分析할 目的으로 試料의 處理 測定 및 各條件에 對하여 檢討하였다. 試料를 Lithium Tetraborate로 용융하여 300Mesh 以上의 微粉末로 한後 40,000Lb의 壓力으로 成型하여 Tungsten과 Chromium 對陰極의 X-線管과 LiF, EDDT, ADP의 分光結晶을 使用하여 測定하였다. 各成分에 對한 檢量曲線은 Matrix Effect를 고려하여 N.B.S 및 International Rock Standard를 選定 使用하였고 Lanthanum Oxide 및 Binder로서 Borie Acid를 첨가하여 얻었다. 各成分에 對하여 本法의 再現性 및 誤差를 檢討하기를 爲하여 I.R.S T-1을 使用하여 測定한 結果 0.47($SiO_2$), 0.85($Al_2O_3$), 0.05($Fe_2O_3$), 0.07(caO), 0.02($K_2O$), 0.13(MgO)의 標準偏差를 얻었다. 또한 化學分析植에 對한 偏差를 求하고져 Clay, Kaoline, Alunite, Wallastonite 및 Zeolite 等의 珪酸鹽鑛物을 選定하여 化學分析 및 本法에 依한 分析結果를 비교하였다.

  • PDF

Geant4를 활용한 국제우주정거장 내의 조직등가비례계수기 모의 실험 (SIMULATION OF THE TISSUE EQUIVALENT PROPORTIONAL COUNTER IN THE INTERNATIONAL SPACE STATION WITH GEANT4)

  • 표정현;이재진;남욱원;김성환;김현옥;임창휘;박귀종;이대희;박영식;문명국
    • 천문학논총
    • /
    • 제27권3호
    • /
    • pp.81-86
    • /
    • 2012
  • The International Space Station (ISS) orbits the Earth within the inner radiation belt, where high-energy protons are produced by collisions of cosmic rays to the upper atmosphere. About 6 astronauts stay in the ISS for a long period, and it should be important to monitor and assess the radiation environment in the ISS. The tissue equivalent proportional counter (TEPC) is an instrument to measure the impact of radiation on the human tissue. KASI is developing a TEPC as a candidate payload of the ISS. Before the detailed design of the TEPC, we performed simulations to test whether our conceptual design of the TEPC will work propertly in the ISS and to predict its performance. The simulations estimated that the TEPC will measure the dose equivalent of about 1:1 mSv during a day in the ISS, which is consistent with previous measurements.

시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교 (Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles)

  • 서혜경;장호영;심수아;김희주;한돈희
    • 한국산업보건학회지
    • /
    • 제32권2호
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.

휘발유 연료용 함산소 첨가제 종류에 따른 성능 특성 연구 Part 2. 배출가스 및 미규제 물질, 입자상 물질 특성 (A study on the characteristics of fuel performance according to the oxygenated additive type for gasoline fuel Part 2. Exhaust and Non-regulated, PM emission characteristics)

  • 이민호;김기호;하종한
    • 한국응용과학기술학회지
    • /
    • 제33권2호
    • /
    • pp.374-384
    • /
    • 2016
  • 대기오염에 관한 관심은 국내 외에서 점진적으로 상승하고 있으며, 자동차와 연료분야 연구자들은 청정 (친환경 대체연료) 연료와 연료품질 향상 등을 이용하여 새로운 엔진 설계, 혁신적인 후 처리 시스템 등의 많은 방법으로 차량 배기가스를 감소시키려고 노력하고 있다. 이러한 연구들은 주로 배출 가스 및 가솔린 차량의 PM 입자 배출 두 가지 이슈로 진행되고 있다. 자동차의 배출가스 및 미규제 물질, PM (입자상 물질) 입자는 환경오염과 인체에 악영향을 주는 많은 문제를 일으키고 있다. 자동차 배출가스의 주요 물질인 입자상 물질은 작은 입자로 구성된다. 이러한 작은 크기 때문에, 흡입된 입자는 쉽게 폐 깊숙이 침투 할 수 있다. 이 입자의 거친 표면들은 대기중에서 다른 독성 물질과 결합하기가 쉽다. 따라서 입자흡입의 위험을 증가시킨다. 함산소 연료첨가제 유형 (MTBE, 바이오 ETBE, 바이오 에탄올, 바이오 부탄올)에 기초하여, 본 논문은 가솔린 자동차 배출가스 및 미규제 물질, 나노입자 배출에 산소함량의 영향을 토론하였다. 또한, 본 논문은 두 가지 시험모드를 사용하여 배출가스 특성을 평가하였다. 시험모드는 FTP-75 및 HWFET 모드이었다. 전체 측정항목에서 배출가스 규제 값보다 적게 배출되고 있는 것을 볼 수 있었고, 산소함량이 증가하면서 측정항목에 따라 증감이 다름을 알 수 있었다.

산화알루미늄 섬유와 니켈분말 후처리공정에서 입자의 노출특성 (Exposure Characteristics of Particles during the After-treatment Processes of Aluminum Oxide Fibers and Nickel Powders)

  • 김종범;김경환;류성희;윤성택;배귀남
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.225-236
    • /
    • 2016
  • Objectives: Nanomaterials have been used in various fields. As use of nanoproducts is increasing, workers dealing with nanomaterials are also gradually increasing. Exposure assessments for nanomaterials have been carried out for protection of worker's health in workplace. Exposure studies were mainly focused on manufacturing processes, but these studies on after-treatment processes such as refinement, weighing, and packing were insufficient. So, we investigated exposure characteristics of particles during after-treatment processes of $Al_2O_3$ fibers and Ni powders. Methods: Mass-production of Ni powder process was carried out in enclosed capture-type canopy hood. In a developing stage, $Al_2O_3$ was handled with a local ventilation unit. Exposure characteristics of particles were investigated for $Al_2O_3$ fiber and Ni powder processes during the periods of 10:00 to 16:00, 20 May 2014 and 13:00 to 16:00, 21 May 2014, respectively. Three real-time aerosol instruments were utilized in exposure assessment. A scanning mobility particle sizer(SMPS, nanoscan, model 3910, TSI) and an optical particle counter(OPC, portable aerosol spectrometer, model 1.109, Grimm) were used to determine the particle size distribution in the size range of 10-420 nm and $0.25-32{\mu}m$, respectively. In addition, a nanoparticle aerosol monitor(NAM, model 9000, TSI) was used to measure lung-deposited nanoparticle surface area. Membrane filters(isopore membrane filter, pore size of 100 nm) were also used for air sampling for the FE-SEM(model S-5000H, Hitachi) analysis using a personal sampling pump(model GilAir Plus by 2.5 L/min, Gilian). Conclusions: For Ni powder after-treatment process, only 27% increase in particle concentration was found during the process. However, for $Al_2O_3$ fiber after-treatment process, significant exposure(1.56-3.34 times) was observed during the process.

이어도 해양종합과학기지에서의 에어로솔 수 농도 변동 (The Fluctuations of Aerosol Number Concentration in the leodo Ocean Research Station)

  • 박성화;이동인;서길종;유철환;장민;강미영;장상민;김동철;최창섭;이병걸
    • 한국환경과학회지
    • /
    • 제18권7호
    • /
    • pp.721-733
    • /
    • 2009
  • To examine the fluctuations of aerosol number concentration with different size in the boundary layer of marine area during summer season, aerosol particles were assayed in the Ieodo Ocean Research Station, which is located 419 km southwest of Marado, the southernmost island of Korea, from 24 June to 4 July, 2008. The Laser Particle Counter (LPC) was used to measure the size of aerosol particles and NCEP/NCAR reanalysis data and sounding data were used to analyze the synoptic condition. The distribution of aerosol number concentration had a large variation from bigger particles more than 3 ${\mu}m$ in diameter to smaller particles more than 1 ${\mu}m$ in diameter with wind direction during precipitation. The aerosol number concentration decreased with increasing temperature. An increase (decrease) of small size of aerosol (0.3${\sim}$0.5 ${\mu}m$ in diameter) number concentration was induced by convergence (divergence) of the wind fields. The aerosol number concentration of bigger size more than 3 ${\mu}m$ in diameter after precipitation was removed as much as 89${\sim}$94% compared with aerosol number concentration before precipitation. It is considered that the larger aerosol particles would be more efficient for scavenging at marine boundary layer. In addition, the aerosol number concentration with divergence and convergence could be related with the occurrence and mechanism of aerosol in marine boundary layer.

이어도 해양종합과학기지에서의 3차원 바람성분에 따른 에어로솔 수 농도 변동 특성 (The Variation of Aerosol Number Concentrations in Relation with 3D Wind Components in the Ieodo Ocean Research Station)

  • 박성화;장상민;이동인;정운선;정종훈;정성아;정창훈;김경식;김경익
    • 대기
    • /
    • 제22권1호
    • /
    • pp.97-107
    • /
    • 2012
  • To investigate variation of aerosol number concentration at each different size with three-dimensional (3D) wind components in ocean area, aerosol particles and 3D wind components were measured in the Ieodo Ocean Research Station, which is located to 419 km southwest from Marado, the southernmost island of Korea, from 25 June to 8 July 2010. The Laser Particle Counter (LPC) and ultrasonic anemometer were used to measure the size of aerosol particles and 3D wind components (zonal (u), meridional (v), and vertical (w) wind) respectively. Surface weather chart, NCEP/NCAR reanalysis data and sounding data were used to analyze the synoptic condition. The distribution of aerosol number concentration had a large variation from bigger particles more than 1.0 ${\mu}m$ in diameter by wind direction during precipitation. In the number concentration of aerosol particles with respect to the weather conditions, particles larger than 1.0 ${\mu}m$ in size were decreased and sustained to the similar concentration at smaller particles during precipitation. The increase in aerosol number concentration was due to the sea-salt particles which was suspended by southwesterly and upward winds. In addition, the aerosol number concentration with vertical wind flow could be related with the occurrence and increasing mechanism of aerosol in marine boundary layer.

용융아연 도금공정에서의 SNOUT 내부 유동장 해석 ( I ) (Velocity Field Measurement of Flow Inside SNOUT of Zinc Plating Process ( I ))

  • 신대식;최제호;이상준
    • 대한기계학회논문집B
    • /
    • 제23권10호
    • /
    • pp.1265-1273
    • /
    • 1999
  • PIV(Particle Image Velocimetry) velocity field measurements inside the snout of a1/10 scale model of the Zn plating process were carried out at the strip speed $V_s=1.5m/s$. Aluminum powder particles ($1{\mu}m$) and atomized olive oil ($3{\mu}m$) were used as seeding particles to simulate the molten Zinc flow and deoxidization gas flow, respectively. A pulsed Nd:Yag laser and a $2K{\times}2K$ high-resolution CCD camera were synchronized for the PIV velocity field measurement. From flow visualization study, it is found that the liquid flow in the Zn pot is dominantly governed by the uprising flow caused by the rotating sink roll, with its effect on the steel strip inside the snout largely diminished by installing of the snout. The deoxidization gas flow in front of the strip inside the snout can be characterized by a large-scale vortex rotating clockwise direction formed by the moving strip. In the rear side of the strip, a counter-clockwise vortex is formed and some of the flow entrained by the moving strip impinges on the free surface of molten zinc. The liquid flow in front of the strip is governed by the flow entering the snout, caused by the spinning sink roll. Just below the free surface a counter-clockwise vortex is formed near the snout wall. The moving strip affects dominantly the flow behind the strip inside the snout, and large amount of the liquid flow follows the moving strip toward the sink roll. The thickness of the flow following the strip is very thin in the front side due to the uprising flow, however thick boundary layer is formed in the rear side of the strip. Its thickness is increased as moving downstream toward the sink roll. Inside the snout, the deoxidization gas flow above the free surface is much faster than the liquid flow in the zinc pot. Due to the larger influx of the flow following the moving strip in the rear side of the strip, higher percentage of imperfection can be anticipated on the rear surface of the strip.