• 제목/요약/키워드: Particle Collection

검색결과 307건 처리시간 0.027초

승용차용 정전 필터의 미세 입자 포집 특성 (Collection Performance of an Electret Cabin Air Filter for Fine Particles)

  • 지준호;강석훈;김동철;황정호;윤웅섭;배귀남
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가 (Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles)

  • 이기혁;김문원;류태우;육세진
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

전기역학적 스크린을 이용한 집진판 표면 위 입자 세정성능 연구 (A study on cleaning performance of particles on collection plates using an electrodynamic screen)

  • 조윤희;신동호;김영훈;박인용;김상복;이건희;한방우
    • 한국입자에어로졸학회지
    • /
    • 제19권3호
    • /
    • pp.63-76
    • /
    • 2023
  • An electrostatic precipitator (ESP) has a low pressure drop and a high collection efficiency but its collection efficiency can be reduced due to dust accumulation on the collection plates during long-term operations. In order to maintain the initial dust collection efficiency, it is necessary to periodically clean the collection plates. The common cleaning methods are using physical impacts or water sprays. These cleaning methods can lead to damage to the collection plate or generate wastewater. Herein, we implemented an electrodynamic screen (EDS) for ESP cleaning and evaluated its surface cleaning performance of particles. The EDS is an electrostatic system that can electrostatically repel particles on surfaces, allowing it to clean the ESP without causing damage and wastewater generation. Our evaluation included the analysis of the effects of AC voltage characteristics, electrode configuration and environmental conditions on the cleaning performance of the EDS with the aim of achieving effective surface cleaning. It has been demonstrated that activating the EDS cleans up to 65% of the particles on the surface, which indicates about 94% of our target cleaning zone.

고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성 (Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates)

  • 이재인;우상희;김종범;이승복;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

클린룸 제조공정에서 수율개선을 위한 입자오염제어 방법 (Method of Particle Contamination Control for Yield Enhancement in the Cleanroom)

  • 노광철;이현철;김대영;오명도
    • 대한기계학회논문집B
    • /
    • 제31권6호
    • /
    • pp.522-530
    • /
    • 2007
  • The practical studies on the method of particle contamination control for yield enhancement in the cleanroom were carried out. The method of the contamination control was proposed, which are composed of data collection, data analysis, improvement action, verification, and implement control. The partition check method and the composition analysis for data collection and data analysis were respectively used in the main board and the cellular phone module production lines. And these methods were evaluated by the variation of yield loss between before and after improvement action. In case that the partition check method was applied, the critical process step was selected and yield loss reduction through improvement actions was observed. While in case that the composition analysis was applied, the critical sources were selected and yield loss reduction through improvement actions was also investigated. From these results, it is concluded that the partition check and the composition analysis are effective solutions for particle contamination control in the cleanroom production lines.

전기집진기의 10 nm 급 초미세 나노입자의 하전 및 집진 특성 (Characteristics of Charging and Collection of 10-nm-Class Ultrafine Nanoparticles in an Electrostatic Precipitator)

  • 한방우;김학준;김용진;송동근;홍원석;신완호
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1013-1018
    • /
    • 2011
  • 전기집진에서의 10 nm 급 초미세 나노입자의 하전 및 집진 특성을 파악하였고, 나노입자의 확산효과와 비교해 보았다. 나노입자의 하전율과 확산손실 효과의 지배력에 따라 전기집진기에서의 나노입자 집진효율이 결정되는 것을 확인할 수 있었다. 10nm 급 영역에서는 입자 크기가 작아질수록 지속적으로 집진효율이 감소하였다. 10 nm 이하의 영역에서는 나노입자의 부분적 하전효과가 전기집진기 내의 확산 손실 효과보다 지배적인 것을 알 수 있었다. 10 nm 이하의 나노입자에 대하여 집진효율 실험 결과가 단극 확산 하전 이론을 적용한 입자하전율 계산 결과와도 잘 일치하였다.