• Title/Summary/Keyword: Partial flow rate

Search Result 230, Processing Time 0.026 seconds

The Discharge Performance Optimization of a Forced Convection Type PCM Refrigeration Module Used in a Refrigeration Truck (냉동트럭용 강제대류방식 PCM 냉동모듈의 방냉성능 최적화에 관한 연구)

  • Lel, Xu;Kim, Wonuk;Lee, Sang-Ryoul;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.624-630
    • /
    • 2013
  • A truck refrigeration system using phase change material (PCM) is expected to have a lower noise level, reduced energy cost, and much lower local greenhouse gas emission. Recently, a forced convection type PCM refrigeration module has been developed. As the operation time increases, the PCM around the air inlet melts, because of a large temperature difference between the PCM and air. Therefore, the latent heat transfer area decreases and the heat transfer rate of the module decreases even though there is a lot of PCM which does not melt around the air outlet. A computational fluid dynamic modeling of the PCM refrigeration module was developed and validated by the experiment. Using the CFD, the design parameters, such as the mass flow rate of the air and roughness of the slab, were investigated to improve the heat transfer inhomogeneity. As a result, the adoption of partial roughness on the slabs improved the heat transfer inhomogeneity and reduced a fan power.

Renal Action of Idazoxan, ${\alpha}_2-Adrenergic$ Antagonist, in Dog (${\alpha}_2-Adrenergic$ Receptor 차단제인 Idazoxan의 신장작용)

  • 고석태;강경원
    • Biomolecules & Therapeutics
    • /
    • v.8 no.2
    • /
    • pp.132-139
    • /
    • 2000
  • This study was performed far investigation of influence on renal function of idazoxan, $\alpha_{2}$-adrenergic antagonist, using the dog. Idazoxan, when giver. into vein, produced the decrease of urine volume(vol) accompanied with the reduction of free water clearance($C_{H2O}$), amounts of sodium excreted in urine($E_{Na}$), with the increase of potassium excreted in urine($E_{K}$), and so ratios of potassium against sodium($K^{+}/Na^{+}$) were elevated, at this time, greatened reabsorption rate of sodium and diministered that of potassium in renal tubules were appeared. Idazoxan administered into a renal artery elicited the augmentation of vol, glomerular filtration rate(GFR), renal plasma flow(RPF) and no change of filtration fraction(FF) in only ipsilateral kidney, whereas $E_{Na},\;E_{K}\;and\;K^{+}/Na^{+}$ were increased and $C_{H2O}$ was decreased in both control and experimental kidney. Idazoxan given into carotid artery showed partial increased vol, remarkable expanded RPF and unchanged GFR, and so filtration fraction(FF) was markedly reduced. Above results suggest that anti- diuretic action of idazoxan given into vein is mediated by reduction of $C_{H2O}\;and\;E_{Na}$, diuretic action only in the ipsilateral kidney by idazoxan given into a renal artery is caused by hemodynamic improvement through expansion of vas afferens in glomeruli.

  • PDF

Controlled Growth of Large-Area Mono-, Bi-, and Few-Layer Graphene by Chemical Vapor Deposition on Polycrystalline Copper Surfaces

  • Kim, Yooseok;Song, Wooseok;Lee, Suil;Cha, Myoung-Jun;Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.614-614
    • /
    • 2013
  • The effect of graphene growth parameters on the number of graphene layers were systematically studied and growth mechanism on copper substrate was proposed. Parameters that could affect the thickness of graphene growth include the pressure in the system, gas flow rate, growth pressure, growth temperature, and cooling rate. We hypothesis that the partial pressure of both the carbon sources and hydrogen gas in the growth process, which is set by the total pressure and the mole fraction of the feedstock, could be the factor that controls the thickness of the graphene. A synthetic method to produce such large area graphene films with precise thickness from mono- to few-layer would be ideal for chemists and physicists to explore the promising electronic applications of these materials. Here, large-area uniform mono-, bi-, and few-layer graphene films were successfully synthesized on copper surface in selective growth windows, with a finely tuned total pressure and $CH_4$/$H_{2gas}$ ratio. Our findings may facilitate both the large-area synthesis of well-controlled graphene features and wide range of applications of graphene.

  • PDF

CONTROL OF CARBON DIOXIDE REMOVAL RATE BY HOLLOW FIBER MEMBRANE CONTACTOR

  • Lee,Yong-Taek;Cho, Ingi;Lim, Hye-Jin;Ahn, Hyo-Seong;Hahm, Moon-Ky;Park, You-In;Lee, Kew-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.48-51
    • /
    • 1999
  • To investigate numerically the removal behavior of carbon dioxide in a hollow fiber membrane contactor, the system controlling equations were developed including the nonlinear reversible reaction terms. The reversible chemical reactions were incorporated in the system controlling equations, resulting in the coupled nonlinear partial differential equations which could describe either the absorption of the desorption of carbon dioxide. The computer program was coded using the Fortran language and run with a personal computer to find out the effects of the system variables: the pressures of absorbed and desorbed gases, the absorbent flow rate, the concentration of potassium carbonate, the fiber diameter and the length.

  • PDF

Salvage of late flap compromise in deep inferior epigastric perforator flaps: To revise or not to revise

  • Hong, Seung Heon;Lee, Kyeong-Tae;Pyon, Jai-Kyong
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.97-101
    • /
    • 2020
  • Although the success rate of deep inferior epigastric perforator (DIEP) flaps has increased, late flap failures still occur and have a low salvage rate. The present article describes a case of salvage of a case of late flap failure using the pedicle vein as a vein graft source. A 50-yearold woman underwent a bilateral DIEP free flap procedure. On postoperative day 6, she experienced flap compromise and underwent emergency flap revision. In the flap revision, flap venous drainage and the superficial inferior epigastric vein were completely obstructed. A Fogarty catheter was used to remove a thrombus from the completely obstructed pedicle vein, and this pedicle vein was used as a graft source and was ligated in retrograde fashion to the flap vein stump. After injection of urokinase into the arterial branch, venous flow to the flap was restored. At a 6-month follow-up visit in the outpatient clinic, only partial fat necrosis at the flap was noted. By dissecting various perforators in the initial operation, decisions regarding immediate revision can be made with more confidence. Additionally, the combined procedures performed in this case may be helpful even for practitioners treating cases of late flap compromise.

The Experimental Study on Antithrombotic Effect of Honghwadangguisan (홍화당귀산(紅花當歸散)의 항혈전(抗血栓) 효과(效果)에 대(對)한 실험적(實驗的) 연구(硏究))

  • Ryou, Dong-Hoon;Shin, Yong-Wan;Kim, Eui-Il;Kim, Su-Min;Lee, Jung-Eun;Yoo, Dong-Youl
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.1
    • /
    • pp.31-46
    • /
    • 2006
  • Purpose : The Purpose of this research was to investigate the effects of antithromb otic activities of Honghwadangguisan(HDS) Methods : Measured the effect which was given to blood flow rate through the regular volume of glass tube after the blood was diluted five times with ACD soulution. Antithrombotic effect was calculated as a percentage of the experimental animal figure protected from the paralysis of hind legs or death of the mouse that is caused from the administration of platelet aggregation regent. Each of the groups consisted in 8 mice, was divided into Normal, Control, and HBS. All of these 3 group were supplied a saline solution and after an hour the control group brought the dextran extravasated blood. Also the HDS group was dosed to the experimental mice with Oral Zonde one day before the experiment. After that, the mice were abstained from food. And then we gave a measured amount of it before an hour. Finally, it gave rise to dextran extravasated blood as well as the Control group. Results : The results were obtained as follows. In vitro, HDS inhibited platelet aggregation induced by ADP and epinephrine significantly as compared with the control group. HDS showed fibrinolytic activity insignificantly as compared with the control group. HDS reduced blood flow rate in significantly as compared with the control group. In vivo HDS inhibited pulmonary embolism induced by collagen and epinephrine (inhibitive rate 50%). HDS increased number of platelet, fibrinogen amount and shortened prothrombin time, activated partial thromboplastin time significantly but reduced blood flow rate insignificantly as compared with the control group in thrombus model induced by dextran. Conclusion : HDS is effective antithrombotic activity from experimental result.

  • PDF

Molecular Beam Epitaxial Growth of Oxide Single Crystal Films

  • Yoon, Dae-Ho;Yoshizawa, Masahito
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.508-508
    • /
    • 1996
  • ;The growth of films have considerable interest in the field of superlattice structured multi-layer epitaxy led to realization of new devices concepts. Molecular beam epitaxy (MBE) with in situ observation by reflection high-energy electron diffraction (RHEED) is a key technology for controlled layered growth on the atomic scale in oxide crystal thin films. Also, the combination of radical oxygen source and MBE will certainly accelerate the progress of applications of oxides. In this study, the growth process of single crystal films using by MBE method is discussed taking the oxide materials of Bi-Sr-Ca-Cu family. Oxidation was provided by a flux density of activated oxygen (oxygen radicals) from an rf-excited discharge. Generation of oxygen radicals is obtained in a specially designed radical sources with different types (coil and electrode types). Molecular oxygen was introduced into a quartz tube through a variable leak valve with mass flowmeter. Corresponding to the oxygen flow rate, the pressure of the system ranged from $1{\;}{\times}{\;}10^{-6}{\;}Torr{\;}to{\;}5{\;}{\times}{\;}10^{-5}$ Torr. The base pressure was $1{\;}{\times}{\;}10^{-10}$ Torr. The growth of Bi-oxides was achieved by coevaporation of metal elements and oxygen. In this way a Bi-oxide multilayer structure was prepared on a basal-plane MgO or $SrTiO_3$ substrate. The grown films compiled using RHEED patterns during and after the growth. Futher, the exact observation of oxygen radicals with MBE is an important technology for a approach of growth conditions on stoichiometry and perfection on the atomic scale in oxide. The oxidization degree, which is determined and controlled by the number of activated oxygen when using radical sources of two types, are utilized by voltage locked loop (VLL) method. Coil type is suitable for oxygen radical source than electrode type. The relationship between the flux of oxygen radical and the rf power or oxygen partial pressure estimated. The flux of radicals increases as the rf power increases, and indicates to the frequency change having the the value of about $2{\times}10^{14}{\;}atoms{\;}{\cdots}{\;}cm^{-2}{\;}{\cdots}{\;}S^{-I}$ when the oxygen flow rate of 2.0 seem and rf power 150 W.150 W.

  • PDF

Performance analysis for the Characteristics of Double/ Single Effect Hybrid type Absorption Chiller (일중/이중효용 하이브리드 타입 흡수식 냉동기 성능 특성에 관한 수치적 연구)

  • You, Da-Young;Song, Tae-Min;Lee, Jung-Byoung;Kim, Hyung-Jin;Im, Ick-Tae;Moon, Sang-Done;Park, Chan-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.272-278
    • /
    • 2009
  • The characteristics of hybrid type absorption chiller are studied numerically to use a waste hot water effectively. In the case of the full load, the concentration and temperature of LiBr solution are increase about $11^{\circ}C$, 1.3% respectively at the single effect generator by hot water. As a result, the heat of the high temperature generator are decrease, so the energy can be saved. As the partial load decreased the consumption ratio of fuels are decreased and the reduction ratio of fuels are increased. The variation of COP with the inlet temperature of hot water is higher than that of the flow rate of hot water. The effect of mean temperature difference with solution and hot water of the generator are higher that of flow rate of hot water, it can effect on COP which is sensitive to heat of generator.

  • PDF

Extracorporeal Membrane Oxygenation in Pediatric Patients with Respiratory Failure: Early Experience with the Double-Lumen Cannula Over 2 Years

  • Kim, Woojung;Kwon, Hye Won;Min, Jooncheol;Cho, Sungkyu;Kwak, Jae Gun;Kim, Woong Han
    • Journal of Chest Surgery
    • /
    • v.53 no.3
    • /
    • pp.132-139
    • /
    • 2020
  • Background: The double-lumen cannula (DLC) has begun to be used worldwide for venovenous (VV) extracorporeal membrane oxygenation (ECMO). We aimed to examine whether the DLC could be an effective tool in the treatment of pediatric respiratory failure in Korea. Methods: We reviewed the records of patients weighing under 15 kg who underwent ECMO due to respiratory failure between January 2017 and December 2018. Outcomes of ECMO using a DLC and conventional ECMO using central method or 2 peripheral cannulas were compared. Results: Twelve patients were treated with ECMO for respiratory failure. Among them, a DLC was used in 5 patients, the median age of whom was 3.8 months (interquartile range, 0.1-49.7 months). In these patients, the median values of pH, partial pressure of carbon dioxide, and partial pressure of oxygen were 7.09, 74 mm Hg, and 37 mm Hg before ECMO and corrected to 7.31, 44 mm Hg, and 85 mm Hg, respectively, after ECMO cannulation. Median blood flow rate in the patients treated with ECMO using a DLC was slightly higher than that in the conventional ECMO group, but this difference was not statistically significant (86.1 mL/kg/min and 74.3 mL/kg/min, respectively; p=1.00). One patient from the DLC group and 3 patients from the conventional group were weaned off ECMO. Conclusion: VV ECMO using a DLC provided adequate oxygenation, ventilation, and blood flow rate in Korean pediatric patients with respiratory failure. Further prospective and randomized studies are warranted.

Numerical Studies of a Separator for Stack Temperature Control in a Molten Carbonate Fuel Cell (용융탄산염 연료전지 스택 온도 조절을 위한 분리판에 관한 수치 해석 연구)

  • Kim, Do-Hyung;Kim, Beom-Joo;Lim, Hee-Chun
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.3
    • /
    • pp.305-312
    • /
    • 2011
  • The use of a separator to control stack temperature in a molten carbonate fuel cell was studied by numerical simulation using a computational fluid dynamics code. The stack model assumed steady-state and constant-load operation of a co-flow stack with an external reformer at atmospheric pressure. Representing a conventional cell type, separators with two flow paths, one each for the anode and cathode gas, were simulated under conditions in which the cathode gas was composed of either air and carbon dioxide (case I) or oxygen and carbon dioxide (case II). The results showed that the average cell potential in case II was higher than that in case I due to the higher partial pressures of oxygen and carbon dioxide in the cathode gas. This result indicates that the amount of heat released during the electrochemical reactions was less for case II than for case I under the same load. However, simulated results showed that the maximum stack temperature in case I was lower than that in case II due to a reduction in the total flow rate of the cathode gas. To control the stack temperature and retain a high cell potential, we proposed the use of a separator with three flow paths (case III); two flow paths for the electrodes and a path in the center of the separator for the flow of nitrogen for cooling. The simulated results for case III showed that the average cell potential was similar to that in case II, indicating that the amount of heat released in the stack was similar to that in case II, and that the maximum stack temperature was the lowest of the three cases due to the nitrogen gas flow in the center of the separator. In summary, the simulated results showed that the use of a separator with three flow paths enabled temperature control in a co-flow stack with an external reformer at atmospheric pressure.