• 제목/요약/키워드: Partial flow rate

검색결과 229건 처리시간 0.028초

TiAIN 코팅한 핵연료봉 피복재의 프레팅 마멸 평가 (Fretting Wear Evaluation of TiAIN Coated Nuclear Fuel Rod Cladding Materials)

  • 김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.88-95
    • /
    • 2002
  • Fretting of fuel rod cladding material, Zircaloy-4 Tube, in PWR nuclear power plants must be reduced and avoided. Nowadays the introduction of surface treatments or coatings is expected to bean ideal solution to fretting damage since fretting is closely related to wear, corrosion and fatigue. Therefore, in this study the fretting wear experiment was peformed using TiAIN coated Zircaloy-4 tube as the fuel rod cladding and uncoated Zircaioy-4 tube as one of grids, especially concentrating on the sliding component. Fretting wear resistance of TiAIN coated Zircaloy-4 tubes was improved compared with that of TiN coated tubes and uncoated tubes and the fretting wear mechanisms were delamination and plastic flow following by brittle fracture at lower slip amplitude but severe oxidation and spallation of oxidative layer at higher slip amplitude.

  • PDF

황화 $Ni-Mo/\gamma - Al_2O_3$ 촉매상에서 Quinoline의 수소첨가탈질반응에 관한 연구 (A Study of Hydrodenitrogenation of Quinoline Catalyzed by Sulfided $Ni-Mo/\gamma - Al_2O_3$)

  • 최응수;이원묵;김경림
    • 한국대기환경학회지
    • /
    • 제5권1호
    • /
    • pp.52-61
    • /
    • 1989
  • The hydrodenitrogenation of quinoline dissolved in n-heptane was studied over sulfided Ni-Mo/$\gamma-Al_2O_3$ catalyst at the range of the temperature between 553 K and 673 and the total pressure between $20 \times 10^5$ Pa and $60 \times 10^5$ Pa in a fixed bed flow reactor. Quinoline conversion was very high at relatively low temperature and total pressure, and decreased with quinoline partial pressure. The thermodynamic equilibrium between quinoline and Py-THQ existed in wide ranges of experimental conditions and shifted in favor of quinoline at higher temperature. At the range of the temperature betwwen 553 K and 673 K and at the total pressure $60 \times 10^5$ Pa, the quinoline reaction rate was 1st order with respect to the concentr4ation of quinoline and its apparent activation energy was 7.15 Kcal/mole.

  • PDF

Undular Bore의 발생과정에 관한 수치 해석 (Numerical Analysis on the Development of an Undularbore)

  • 배헌민;김인철
    • 수산해양기술연구
    • /
    • 제22권2호
    • /
    • pp.31-35
    • /
    • 1986
  • A bore is a transition between different uniform flows of water. If a long wave of elevation travels in shallow water it steepens and forms a bore. The bore is undular if the change in surface elevation of the wave is less than 0.28 of the original depth of water. This paper describes the growth of an undular bore from a long wave which forms a gentle transition between a uniform flow and still water. A physical account of its development is followed by the results of numerical calculations. Finite-difference approximations are used in the partial differential equations of motion. For undular bores, numerical calculations show that (i) the relationship between relative elevation and relative velocity given by long wave theory is approached for an undular bore, (ii) the amplitude of first crest of an undular bore approaches a finite limit approximately at an exponential rate, and (iii) the distance between the first two crests increases without bound, approximately logarithmically.

  • PDF

난류연소 모델링을 이용한 수소-공기 비예혼합 화염의 NOx 생성 분석 (Analysis of NO Formation in Nonpremixed Hydrogen-Air Flames Considering Turbulence-Chemistry Interaction)

  • 박양호;문희장;김성룡;윤영빈;정인석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.71-79
    • /
    • 1999
  • Numerical analysis on the characteristics of nitrogen oxides (NOx) formation in turbulent nonpremixed hydrogen-air flames was carried out. Lagrange IEM model and Assumed PDF model were applied to consider turbulence-chemistry interaction known to affect the production of NOx. Partial equilibrium assumption was used to predict nonequilibrium effect to which one-half power dependence between EINOx normalized by flame residence time and global strain rate is attributed. As a result. such one-half power dependence could be reproduced only by reaction model including $HO_{2}$and $H_{2}O_{2}$, which means its dependence on Damkohler number; nonequilibrium effect. This dependence was shown better in the region of higher global strain. Besides, the improvement of turbulence model is required to predict mean flow properties quantitatively in the radial direction.

  • PDF

나노임프린트 리소그래피 공정에서 Slip에 의한 경계 효과 (Effect of Boundary Slip Phenomena in Nanoimprint Lithography Process)

  • 이영훈;김남웅;신효철
    • 한국공작기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.144-153
    • /
    • 2009
  • It is widely known that no-slip assumptions are often violated on regular basis in micrometer- or nanometer-scale fluid flow. In the case of cavity-filling process of nanoimprint lithography(NIL), slip phenomena take place naturally at the solid-to-liquid boundaries, that is, at the mold-to-polymer or polymer-to-substrate boundaries. If the slip or partial slip phenomena are promoted at the boundaries, the processing time of NIL, especially of thermal-NIL which consumes more tact time than that of UV-NIL, can be significantly improved. In this paper it is aimed to elucidate how the cavity-filling process of NIL can be influenced by the slip phenomena at boundaries and to what degree those phenomena increase the process rate. To do so, computational fluid dynamics(CFD) analysis of cavity filling process has been carried out. Also, the effect of mold pattern shape and initial thickness of polymer resist were considered in the analysis, as well.

냉동사이클의 최적 제어를 위한 증발기 동특성 해석 (Dynamic Analysis of Evaporator for Optimum Control in Refrigeration System)

  • 정석권;;최광환;윤정인;김은필
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.82-88
    • /
    • 2005
  • This paper presents numerical study on dynamic characteristics of evaporator to control evaporator superheat and compressor capacity with optimum condition in refrigeration system. It is very important to reduce energy consumption and to keep room temperature within a very restricted range with minimum oscillation in some special applications of the refrigeration system. Heat exchange is mainly happened in the evaporator. So, making mathematical model of evaporator and analyzing evaporator characteristics are necessary in order to control the superheat and the capacity of the system. A mathematical model based on the one dimensional partial differential equations representing mass and energy conservation and a tube-wall energy is described. A set of ordinary differential equation is formulated by integrating separately over the two regions(two-phase and vapor) generally presented in a heat exchanger.

  • PDF

Optimal Design and Test of Fuel-Rich Gas Generator

  • Lee, Changjin;Kwon, Sun-Tak
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.560-564
    • /
    • 2004
  • The optimal design and combustion analysis of the gas generator for Liquid Rocket Engine (LRE) were performed. A fuel-rich gas generator in open cycle turbopump system was designed for 10ton$_{f}$ in thrust with RP-1/Lox propellant. The optimal design was done for maximizing specific impulse of main combustion chamber with constraints of combustion temperature and power matching required by turbopump system. Design variables were selected as total mass flow rate to gas generator, O/F ratio in gas generator, turbine injection angle, partial admission ratio, and turbine rotational speed. Results of optimal design show the dimension of length, diameter, and contraction ratio of gas generator. Also, the combustion test was conducted to evaluate the performance of injector and combustion chamber. And the effect of the turbulence ring was investigated on the mixing enhancement in the chamber.r.

  • PDF

유동대전에 의한 절연유중의 정전기 방전기구와 대책에 관한 연구 (A Study on the Mechanism and Countermeasure of Electrostatic Discharge in Insulating Oil by Streaming Electrification)

  • 박광현;임헌찬;김두식;황명환;육재호;이덕출
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.10-15
    • /
    • 1993
  • In this paper, it is studied the electrostatic discharge In Insulating oil for the purpose of the technical control of the streaming electrification resulted from the interface between an insulating liquid and a solid. The streaming current increases exponentially with flow rate and In region of lower than 50[$^{\circ}C$]but decreases at higher than the same temperature. The phenomena of electrostatic discharge appear at an interface between measuring tank and insulating oil when the seven sheets of gauzes are inserted in electrification apparatus. And those of partial or surface discharge are shown when eight sheets are inserted.

  • PDF

$K^+$ Channel 개방제인 BRL 34915의 신장작용 (Renal Action of BRL 34915, a $K^+$ Channel Opener, in Dog)

  • 고석태;최홍석
    • 약학회지
    • /
    • 제44권3호
    • /
    • pp.205-212
    • /
    • 2000
  • The effect of BRL 34915, a $K^{+}$ channe$Na^{+}$l opener, on renal function was investigated in anesthetized dog. BRL 34915, when given into the vein, elicited the decrease of urine volume accompanied with the reduction of renal plasma flow (RPF), osmolar clearance ($C_{osm}$) and amounts of sodium excreted into urine ($E_{na}$), whereas reabsorption rate of sodium in renal tubules ($R_{na}$), ratio of $K^{+}$ against $Na^{+}$ in urine ($K^{+}$ /$Na^{+}$) were elevated significantly with a partial fall of mean arterial pressure (MAP). BRL 34915 injected into a renal artery produced the diuretic action along with the increase in RPF $C_{osm}$, $E_{na}$ and amounts of potassium excreted in urine ($E_{k}$), and the decrease in $R_{na}$, reabsorption rate of potassium in renal tubules ($R_{k}$), free water clearance ($C_{H20}$) and $K^{+}/Na^{+}$ ratio in only ipsilateral kidney, however changes of the renal function were not observed in control kidney. BRL 34915 given into carotid artery exhibited the same aspect as changes of renal function induced by intravenous BRL 34915. These results suggest that BRL 34915 has dual effects, renally acting diuretic and centrally acting antidiuretic action.n.

  • PDF

냉동트럭용 강제대류방식 PCM 냉동모듈의 방냉성능 최적화에 관한 연구 (The Discharge Performance Optimization of a Forced Convection Type PCM Refrigeration Module Used in a Refrigeration Truck)

  • ;김원욱;이상렬;김용찬
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.624-630
    • /
    • 2013
  • A truck refrigeration system using phase change material (PCM) is expected to have a lower noise level, reduced energy cost, and much lower local greenhouse gas emission. Recently, a forced convection type PCM refrigeration module has been developed. As the operation time increases, the PCM around the air inlet melts, because of a large temperature difference between the PCM and air. Therefore, the latent heat transfer area decreases and the heat transfer rate of the module decreases even though there is a lot of PCM which does not melt around the air outlet. A computational fluid dynamic modeling of the PCM refrigeration module was developed and validated by the experiment. Using the CFD, the design parameters, such as the mass flow rate of the air and roughness of the slab, were investigated to improve the heat transfer inhomogeneity. As a result, the adoption of partial roughness on the slabs improved the heat transfer inhomogeneity and reduced a fan power.