• Title/Summary/Keyword: Partial factor

Search Result 1,132, Processing Time 0.028 seconds

Reliability-Based Structural Integrity Assessment of Wall-Thinned Pipes Using Partial Safety Factor (부분안전계수를 이용한 감육배관의 신뢰도 기반 건전성 평가)

  • Lee, Jae-Bin;Huh, Nam-Su;Park, Chi-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3_1spc
    • /
    • pp.518-524
    • /
    • 2013
  • Recently, probabilistic assessments of nuclear power plant components have generated interest in the nuclear industries, either for the efficient inspection and maintenance of older nuclear plants or for improving the safety and cost-effective design of newly constructed nuclear plants. In the present paper, the partial safety factor (PSF) of wall-thinned nuclear piping is evaluated based on a reliability index method, from which the effect of each statistical variable (assessment parameter) on a certain target probability is evaluated. In order to calculate the PSF of a wall-thinned pipe, a limit state function based on the load and resistance factor design (LRFD) concept is first constructed. As for the reliability assessment method, both the advanced first-order second moment (AFOSM) method and second-order reliability method (SORM) are employed to determine the PSF of each probabilistic variable. The present results can be used for developing maintenance strategies considering the priorities of input variables for structural integrity assessments of wall-thinned piping, and this PSF concept can also be applied to the optimal design of the components of newly constructed plants considering the target reliability levels.

Load & Resistance Factors Calibration for Limit State Design of Non-Perforated Caisson Breakwater (직립무공케이슨방파제 한계상태설계를 위한 하중저항계수 보정)

  • Kim, Dong Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.351-355
    • /
    • 2019
  • Load resistance factors for the limit state design of vertical caisson breakwaters are presented. Reliability analysis of 16 breakwaters in nationwide ports was conducted to calculate the partial safety factors and they were converted into load and resistance factors. The final load resistance factor was calibrated by applying the optimization technique to the individually calculated load resistance factors. Finally, the breakwater was redesigned using the optimal load resistance factor and verified whether the target level was met. The load resistance factor according to the change of the target reliability level is presented to facilitate the limit state design of breakwater.

The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module (부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치)

  • Suh, Ki-Young;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.183-190
    • /
    • 2004
  • This paper proposes a methodology to solve problems upon the circuit design applied to inductor load by applying a circuit to improve power factor with is partial switching PFC module to the power supply system for cooling/heating inverter air conditioner and by designing an input power section in compliance with IEC555-2 on the basis of better input power factor and minimized harmonic components of current. On the other hand, this paper suggested how to control the increase of output voltage along with tぉw current waves and partial switching PFC circuit as well, which can provide the output as twice as input voltage This study applied a method to control the compressors of air conditioner by means of increased the voltage applicable to compressor motor by lowering switching number conclusively, it could solve questions about efficiency, economics, electronic noise and so forth. and so that the reasonable voltage for running moor could be set up along with lower power consumption of air conditioner than estimated It was demonstrated that total sum of energy efficiency to operate system was increased to the extent of valid level. And all this merits and appropriateness was proved by computer simulation and experience.

Design models for predicting the resistance of headed studs in profiled sheeting

  • Vigneri, Valentino;Hicks, Stephen J.;Taras, Andreas;Odenbreit, Christoph
    • Steel and Composite Structures
    • /
    • v.42 no.5
    • /
    • pp.633-647
    • /
    • 2022
  • This paper presents the results from reliability analyses of the current Eurocode 4 (EN 1994-1-1) and AISC 360-16 design models for predicting the resistance of headed stud shear connectors within profiled steel sheeting, when the ribs are oriented transverse to the supporting beam. For comparison purposes, the performance of the alternative "Luxembourg" and "Stuttgart" model were also considered. From an initial database of 611 push-out tests, 269 cases were included in the study, which ensured that the results were valid over a wide range of geometrical and material properties. It was found that the current EN 1994-1-1 design rules deliver a corrected partial safety factor γM* of around 2.0, which is significantly higher than the target value 1.25. Moreover, 179 tests fell within the domain of the concrete-related failure design equation. Notwithstanding this, the EN 1994-1-1 equations provide satisfactory results for re-entrant profiled sheeting. The AISC 360-16 design equation for steel failure covers 263 of the tests in the database and delivers 𝛾M*≈2.0. Conversely, whilst the alternative "Stuttgart" model provides an improvement over the current codes, only a corrected partial safety factor of 𝛾M*=1.47 is achieved. Finally, the alternative "Luxembourg" design model was found to deliver the required target value, with a corrected partial safety factor 𝛾M* between 1.21 and 1.28. Given the fact that the Luxembourg design model is the only model that achieved the target values required by EN 1990, it is recommended as a potential candidate for inclusion within the second generation of Eurocodes.

A Study on the Decision-making Factors of Living-in Idea into Unsold Apartment of Metropolitan Area (수도권 미분양아파트 구매의사결정 영향요인 분석)

  • Tak, Jung-Ho;Rho, Jeong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.247-255
    • /
    • 2017
  • The study figured out the preference factors which should be considered for investor on decision making of unsold apartment and analyzed by comparing the difference according to the type. Then, it investigated the preference factors through the previous studies to analyze the influence factor of decision making and demonstrated the effects through the PLS (Partial Least Squares) regression. In addition, it separated the target type to tenants and construction firms and carried out the survey for comparing the preference factors of investor type. The result of analysis found out that tenants emphasis on preference factors such as the internal factor (1.141), conditional relaxation (1.114), environment factor (1.107), social factor (1.048), external factor (1.030), educational environment factor (1.010) and etc. Then, construction firms emphasis on preference factors such as the social factor (1.401), environment factor (1.251), conditional relaxation (1.133) and etc. In addition, common preferences factors are the conditional relaxation, social factor, environment factor.

A Study on Partial Resonant AC-DC Chopper of Power Factor Correction (역률개선형 부분공진 AC-DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • In this paper, author proposes a novel step-up AC-DC chopper operated with power factor correction(PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control(DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching rum-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Effects of Korean Female Consumer's Propensity to Consume Cosmetics on the Product Selection Attributes and Information Search Behavior (한국 여성 소비자의 화장품 소비성향이 제품선택속성과 정보탐색행동에 미치는 영향)

  • Joo, Young-Joo
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.7
    • /
    • pp.61-74
    • /
    • 2019
  • The purpose of this study is to examine women's propensity to consume cosmetics and to investigate the effects of the consumption propensity on product selection attributes and information search behaviors. The purpose of this study is to propose practical implications for corporate management and to provide useful information for setting the marketing direction in the cosmetics industry by identifying differentiated marketing strategy for the cosmetics market. The results of the study are as follows. When the factors of each variable are extracted, the shopping propensity was derived from trend pursuit, pleasure pursuit, show-off pursuit, and economic benefit pursuit propensities, while product selection attributes were derived from brand factor, service factor, marketing factor, and quality factor. To examine the relationship between variables, three hypotheses were set based on previous studies. As a result of the verification the followings were found; first, the consumption propensity has a partial effect on the product selection attributes. Second, consumption propensity has a partial effect on information search behavior. Product selection attributes were found to have a partial effect on information search behavior.

Reliability Analysis and Evaluation of Partial Safety Factors of Breakwater Armor stones Considering Correlation between Wave Height and Wave Steepness (파고와 파형경사의 상관성을 고려한 피복석의 신뢰성 해석 및 부분안전계수 산정)

  • Kim, Seung-Woo;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.3
    • /
    • pp.300-309
    • /
    • 2008
  • The partial safety factors of armor stones have been calculated on the assumption that all random variables are independent one another. However, wave height and wave steepness are not independent in the van der Meer's formula of armor stones but they are correlated. In the present study, we calculated the partial safety factors considering the correlation and compared them with those of other researchers who did not consider the correlation. The correlation between wave height and steepness is closely related to the variability of wave period. As the variability of wave period decreases, the correlation between wave height and steepness becomes strong, and hence the calculation results with and without consideration of the correlation show more difference. Therefore, the correlation should be taken into account in the calculation of partial safety factors in the area where the variability of wave period is small.

An efficient partial mixed finite element model for static and free vibration analyses of FGM plates rested on two-parameter elastic foundations

  • Lezgy-Nazargah, M.;Meshkani, Z.
    • Structural Engineering and Mechanics
    • /
    • v.66 no.5
    • /
    • pp.665-676
    • /
    • 2018
  • In this study, a four-node quadrilateral partial mixed plate element with low degrees of freedom (dofs) is developed for static and free vibration analysis of functionally graded material (FGM) plates rested on Winkler-Pasternak elastic foundations. The formulation of the presented finite element model is based on a parametrized mixed variational principle which is developed recently by the first author. The presented finite element model considers the effects of shear deformations and normal flexibility of the FGM plates without using any shear correction factor. It also fulfills the boundary conditions of the transverse shear and normal stresses on the top and bottom surfaces of the plate. Beside these capabilities, the number of unknown field variables of the plate is only six. The presented partial mixed finite element model has been validated through comparison with the results of the three-dimensional (3D) theory of elasticity and the results obtained from the classical and high-order plate theories available in the open literature.

Analysis of Probabilities of Failure and Partial Safety Factors of Armor Units on Tranding and Coastal Harbors (무역항 및 연안항 피복재의 파괴확률과 부분안전계수 해석)

  • Lee, Cheol-Eung;Park, Dong-Heon
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.157-165
    • /
    • 2008
  • Level II AFDA and Level III MCS reliability models are applied to analyze the stability of armor units on trading and coastal harbors in Korea. Hudson's formula and Van der Meer's formula are used in this reliability analysis. Also, probability density functions of reliability index and probability of failure are derived by the additional analysis. In addition, the partial safety factors of all harbors related to armor units can be straightforwardly evaluated by the inverse-reliability method. The upper and lower limits and average level of partial safety factors can be statistically investigated with the results of all cases applied in this paper. Therefore, it may be possible to design armor units of new breakwaters including the uncertainty of random variable and target level by using the present results.

  • PDF