• Title/Summary/Keyword: Partial Least Squares(PLS)

Search Result 383, Processing Time 0.024 seconds

Non-Destructive Prediction of Head Rice Ratios using NIR Spectra of Hulled Rice (정조 상태에서 백미에 대한 완전미율의 비파괴 예측)

  • Kwon, Young-Rip;Cho, Seung-Hyun;Lee, Jae-Heung;Seo, Kyoung-Won;Choi, Dong-Chil
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • The purpose of this study was to measure fundamental data required for the prediction of milling ratios, and to develop regression models to predict the head rice ratio of milled rice using NIR spectra of hulled rice. A total of 81 rice samples used in this study were collected from Jeongeup, Jeonbuk province in 2006. NIR spectra were measured using one mode of measurement, reflection. The reflectance spectra were measured in the wavelength region of 400-2500 nm with an NIR spectrophotometer "NIRSystems 6500" (Foss, Silverspring, USA). Calibration equations were developed by the modified partial least squares (MPLS), partial least squares (PLS), and principal components regression (PCR). Math treatments were 1-4-4-1, 1-10-10-1, 2-4-4-1, and 2-10-10-1. The software used was WinISI (Infrasoft International, State College, USA). Automatic head rice production and quality checking system used was "SY2000-AHRPQCS" (Ssangyong, Korea). The calibration was made with the first derivative and the spectrum designated was in 8 nm interval. The determination coefficients of head rice ratios were 0.8353, 0.8416 and 0.5277 for the MPLS, PLS and PCR, respectively. Those obtained with 20 nm interval were 0.8144, 0.8354 and 0.6908 for the MPLS, PLS and PCR, respectively. The calibration was made with second derivative that spectrum designated was 8 nm in interval. The determination coefficients of head rice ratios were 0.7994, 0.8017 and 0.4473 for the MPLS, PLS and PCR, respectively. Those with 20 nm interval were 0.8004, 0.8493 and 0.6609 for the MPLS, PLS and PCR, respectively. These results indicate that the accuracy of determination coefficient for MPLS and PLS is higher than that of PCR.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Analysis of internet addiction in Korean adolescents using sparse partial least-squares regression (희소 부분 최소 제곱법을 이용한 우리나라 청소년 인터넷 중독 자료 분석)

  • Han, Jeongseop;Park, Soobin;Lee, onghwan
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.2
    • /
    • pp.253-263
    • /
    • 2018
  • Internet addiction in adolescents is an important social issue. In this study, sparse partial least-squares regression (SPLS) was applied to internet addiction data in Korean adolescent samples. The internet addiction score and various clinical and psychopathological features were collected and analyzed from self-reported questionnaires. We considered three PLS methods and compared the performance in terms of prediction and sparsity. We found that the SPLS method with the hierarchical likelihood penalty was the best; in addition, two aggression features, AQ and BSAS, are important to discriminate and explain latent features of the SPLS model.

Comparative Analysis of Cultivation Region of Angelica gigas Using a GC-MS-Based Metabolomics Approach (GC-MS 기반 대사체학 기술을 응용한 참당귀의 산지비교분석)

  • Jiang, Guibao;Leem, Jae Yoon
    • Korean Journal of Medicinal Crop Science
    • /
    • v.24 no.2
    • /
    • pp.93-100
    • /
    • 2016
  • Background: A set of logical criteria that can accurately identify and verify the cultivation region of raw materials is a critical tool for the scientific management of traditional herbal medicine. Methods and Results: Volatile compounds were obtained from 19 and 32 samples of Angelica gigas Nakai cultivated in Korea and China, respectively, by using steam distillation extraction. The metabolites were identified using GC/MS by querying against the NIST reference library. Data binning was performed to normalize the number of variables used in statistical analysis. Multivariate statistical analyses, such as Principal Component Analysis (PCA), Partial Least Squares-Discriminant Analysis (PLS-DA), and Orthogonal Partial Least Squares-Discriminant Analysis (OPLS-DA) were performed using the SIMCA-P software. Significant variables with a Variable Importance in the Projection (VIP) score higher than 1.0 as obtained through OPLS-DA and those that resulted in p-values less than 0.05 through one-way ANOVA were selected to verify the marker compounds. Among the 19 variables extracted, styrene, ${\alpha}$-pinene, and ${\beta}$-terpinene were selected as markers to indicate the origin of A. gigas. Conclusions: The statistical model developed was suitable for determination of the geographical origin of A. gigas. The cultivation regions of six Korean and eight Chinese A. gigas. samples were predicted using the established OPLS-DA model and it was confirmed that 13 of the 14 samples were accurately classified.

Visualizing (X,Y) Data by Partial Least Squares Method (PLS 기법에 의한 (X,Y) 자료의 시각화)

  • Huh, Myung-Hoe;Lee, Yong-Goo;Yi, Seong-Keun
    • The Korean Journal of Applied Statistics
    • /
    • v.20 no.2
    • /
    • pp.345-355
    • /
    • 2007
  • PLS methods are suited for regressing q-variate Y variables on p-variate X variables even in the presence of multicollinearity problem among X variables. Consequently, they are useful for analyzing datasets with smaller number of observations compared to the number of variables, such as NIR(near-infrared) spectroscopy data in chemometrics. In this study, we propose two visualizing methods of p-variate X variables and q-variate Y variable that can be used in connection with PLS analysis.

Rapid Compositional Analysis of Naphtha by Near-Infrared Spectroscopy

  • 구민식;정호일;이준식
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.11
    • /
    • pp.1189-1193
    • /
    • 1998
  • The determination of total paraffin, naphthene, and aromatic (PNA) contents in naphtha samples, which were directly obtained from actual refining process, has been studied using near-infrared (NIR) spectroscopy. Each of the total PNA concentrations in naphtha has been successfully analyzed using NIR spectroscopy. Partial least squares (PLS) regression method has been utilized to quantify the total PNA contents in naphtha from the NIR spectral bands. The NIR calibration results showed an excellent correlation with those of conventional gas chromatography (GC). Due to its rapidity and accuracy, NIR spectroscopy is appeared as a new analytical technique which can be substituted for the conventional GC method for the quantitative analysis of petrochemical products including naphtha.

Soft Sensor Development for Predicting the Relative Humidity of a Membrane Humidifier for PEM Fuel Cells (고분자 전해질 연료전지용 막가습기의 상대습도 추정을 위한 소프트센서 개발)

  • Han, In Su;Shin, Hyun Khil
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.491-499
    • /
    • 2014
  • It is important to accurately measure and control the relative humidity of humidified gas entering a PEM (polymer electrolyte membrane) fuel cell stack because the level of humidification strongly affects the performance and durability of the stack. Humidity measurement devices can be used to directly measure the relative humidity, but they cost much to be equipped and occupy spaces in a fuel cell system. We present soft sensors for predicting the relative humidity without actual humidity measuring devices. By combining FIR (finite impulse response) model with PLS (partial least square) and SVM (support vector machine) regression models, DPLS (dynamic PLS) and DSVM (dynamic SVM) soft sensors were developed to correctly estimate the relative humidity of humidified gases exiting a planar-type membrane humidifier. The DSVM soft sensor showed a better prediction performance than the DPLS one because it is able to capture nonlinear correlations between the relative humidity and the input data of the soft sensors. Without actual humidity sensors, the soft sensors presented in this work can be used to monitor and control the humidity in operation of PEM fuel cell systems.

Analysis of biodiesel quality based on infrared spectroscopy and multivariate statistics (적외선 분광분석과 다변량 통계에 기반한 바이오디젤 품질분석)

  • Kim, Hye-Sil;Cho, Hyun-Woo;Liu, J. Jay
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.214-222
    • /
    • 2012
  • ASTM (American Society for Testing and Materials) D6751-10 suggests analytical methods as well as specifications for biodiesel quality. However, it is expensive and time-consuming to follow the ASTM testing methods to analyze biodiesel and various impurities. This paper develops a quantitative analysis system for biodiesel and impurities based on Infrared spectroscopy and a multivariate statistical method, PLS (partial least squares). In addition, four different pre-processing techniques were compared for spectrum correction and noise reduction. Savitzky-Golay pre-processing showed the best performance.

Discrimination model for cultivation origin of paper mulberry bast fiber and Hanji based on NIR and MIR spectral data combined with PLS-DA (닥나무 인피섬유와 한지의 원산지 판별모델 개발을 위한 NIR 및 MIR 스펙트럼 데이터의 PLS-DA 적용)

  • Jang, Kyung-Ju;Jung, So-Yoon;Go, In-Hee;Jeong, Seon-Hwa
    • Analytical Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.7-16
    • /
    • 2019
  • The objective of this study was the development of a discrimination model for the cultivational origin of paper mulberry bast fiber and Hanji using near infrared (NIR) and mid infrared (MIR) spectroscopy combined with partial least squares discriminant analysis (PLS-DA). Paper mulberry bast fiber was purchased in 10 different regions of Korea, and used to make Hanji. PLS-DA was performed using pre-treated FT-NIR and FT-MIR spectral data for paper mulberry bast fiber and Hanji. PLS-DA of paper mulberry bast fiber and Hanji samples, using FT-NIR spectral data, showed 100 % performance in cross validation and the confusion matrix (accuracy, sensitivity, and specificity). The discrimination models showed four regional groups which demonstrated clearer separation and much superior score plots in the NIR spectral data-based model than in the MIR spectral data-based model. Furthermore, the discrimination model based on the NIR spectral data of paper mulberry bast fiber had highly similar score morphology to that of the discrimination model based on the NIR spectral data of Hanji.

Analyzing Management Factors on Enterprise Performance

  • Dahlgaard, Jens J.;Ciavolino, Enrico
    • International Journal of Quality Innovation
    • /
    • v.8 no.3
    • /
    • pp.1-10
    • /
    • 2007
  • A sample of Italian manufacturing companies was selected in order to verify the abilities and effects (relationships) of the management factors human resources, leadership and strategic planning on company performance. The Partial Least Squares (PLS) estimation method was used for analyzing the data collected, where the relationships between the management factors and performance were formalized by a Structural Equation Model (SEM). The analysis of the survey data showed unexpected result regarding the non significant direct relationship between Leadership and Performance. The effect of Leadership is obtained by an indirect relationship through Human Resources. The combination of Leadership and Human Resources has hence been identified as the management factors which have the highest impact on the performance of Italian industrial companies. Another interesting and unexpected result was that there was no significant impact of Strategic Planning on Performance. It seems that the leaders of Italian industrial companies have not understood that good strategic planning is a necessary condition for achieving excellence. So another improvement area is in fact Strategic Planning. This area should have the highest priority of any top management team and the focus should include how to establish a strong relationship between strategic planning and performance. No correlation between strategic planning and performance is a strong indication that something is wrong. It is not enough that Leadership is doing Strategic Planning-Leadership is also about studying and follow up on results in order to assure impacts on performance. This link seems to be missing in Italian industrial companies.