• 제목/요약/키워드: Parotid cancer

검색결과 76건 처리시간 0.021초

두경부 선낭암종의 예후와 원격 전이 (Oncologic Outcome and Distant Metastasis of Head and Neck Adenoid Cystic Carcinoma)

  • 윤희수;박상규;박혜진;송창면;지용배;태경
    • 대한두경부종양학회지
    • /
    • 제34권2호
    • /
    • pp.23-28
    • /
    • 2018
  • Background/Objectives: Adenoid cystic carcinoma is the second most common salivary carcinoma. It occurs commonly in the submandibular gland, sublingual gland and minor salivary gland. Local recurrence and distant metastasis are the leading cause of death. The aim of this study was to evaluate long-term oncologic outcomes of patients with head and neck adenoid cystic carcinoma focusing on distant metastasis. Materials & Methods: We retrospectively studied 39 patients who were diagnosed with and treated for adenoid cystic carcinoma of the head and neck from December 1996 to May 2018. The clinicopathologic characteristics of patients such as age, sex, primary site and TNM stage, and treatment methods, recurrence and distant metastasis after treatment, survival rate, and treatment method for recurrence were analyzed. Results: Of 39 patients, 18 were males and 21 were females, and the mean age was $5.9{\pm}14.4$ (28-89) years. The most common primary site was oral cavity (12 cases), and followed by sino-nasal cavity (11 cases), parotid gland (5 cases), and etc. For treatment, 17 patients underwent surgery alone, 16 received surgery with postoperative radiation therapy, and 3 patients received radiation therapy only. Three patients refused any further treatments. Recurrence occurred in 15 patients. The most common site of recurrence was the lung. The mean time to recurrence was 31.7 months. The 5 and 10 years' overall survival rate was 79.3% and 74%, respectively. The 2 and 5 years' overall survival rate was 69.6% and 62.6% in patients with distant metastasis. Conclusion: Distant metastasis is an important prognostic factor in adenoid cystic carcinoma, and eventually one third of patients have distant metastasis, especially in the lung. An appropriate treatment for lung metastasis is necessary because some patients with pulmonary metastasis survive for a quite long time.

CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향 (Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer))

  • 장재욱;한만석;김민정;강현수
    • 한국자기학회지
    • /
    • 제26권5호
    • /
    • pp.173-178
    • /
    • 2016
  • 두경부와 전립선 암 환자에서 CT조영제가 방사선치료계획에 미치는 영향을 확인하고 선량계산 정확성 향상을 위하여 본 연구를 실시하였다. 30명의 환자에 대하여 Pinnacle 8.0 시스템을 이용하여 조영제에 의한 조직의 전자밀도 변화를 측정하였으며 각각의 방사선치료계획을 통한 선량계산을 실시하였다. Pinnacle과 Tomotherapy planning 시스템을 이용하여 각각의 전자밀도와 3D 입체조형방사선치료(3D CRT)와 세기변조방사선치료(IMRT)계획을 수립하였다. 조영제에 의한 전자밀도의 변화는 4%이하로 두경부: 표적용적 2.1%, 이하선 1.9%, 하악선 3.6%, 혀 0.9%, 척수 0.3%, 식도 2.6%, 하악골 0.1%, 전립선: 표적용적 0.7%, 림프절 1.1%, 방광 1.2%, 직장 1.5%, 소장 1.2%, 대장 0.6%, penile bulb 0.8%, 대퇴골두 -0.2%로 나타났다. 선량계산의 차이는 2.5% 이하의 선량 증가가 발생하였다(3D CRT: 두경부 0.69~2.51%, 전립선 0.04~1.14%, IMRT: 두경부 0.58~1.31%, 전립선 0.36~1.04%). 이러한 오차는 임상에서 허용 가능한 오차 이내이지만 영상융합(조영증강 영상과 조영증강 하지않은 영상)이나 ROI import 기능을 활용하여 조영 증강하지 않은 영상에서 선량계산을 실시한다면 1~3%의 방사선치료계획 선량 오차를 줄일 수 있을 것으로 기대된다.

비인강암의 세기조절방사선치료기술을 이용한 동시차등조사가속치료의 예비성적 ('Simultaneous Modulated Accelerated Radiation Therapy' (SMART) Intensity-Modulated Radiotherapy in the Treatment of Nasopharyngeal Carcinoma : the Asan Medical Center)

  • 이상욱;백금문;이병용;최은경;김종훈;안승도;신성수;김상윤;남순열;최승호;김성배;송시열
    • 대한두경부종양학회지
    • /
    • 제19권1호
    • /
    • pp.9-15
    • /
    • 2003
  • Purpose: To introduce our early experience with intensity-modulated radiotherapy (IMRT) in the treatment of nasopharyngeal carcinoma. Methods and Materials: Eight patients who underwent IMRT for no disseminated nasopharyngeal carcinoma at the Asan Medical Center between September 2001 and November 2002 were evaluate by prospective analysis. According to the 1997 American Joint Committee on Cancer staging classification, 5 had Stage III, and 3 had Stage IVB disease. The IMRT plans were designed to be delivered as a 'Simultaneous Modulated Accelerated Radiation Therapy' (SMART) using the 'step and shoot' technique with a MLC (multileaf collimator). Daily fractions of 2.2-2.5Gy and 1.9-2Gy were prescribed and delivered to the GTV and CTV and clinically negative neck node, respectively. The prescribed dose was 70A-79.0Gy to the gross tumor volume (GTV), 60Gy to the clinical target volume (CTV) and metastatic nodal station, and 46Gy to the clinically negative neck. All patients also received weekly cisplatin during radiotherapy. Acute and late normal tissue effects were graded according to the Radiation Therapy Oncology Group (RTOG) radiation morbidity scoring criteria. Results: Follow-up period was ranging from 5 to 18 months. All patients showed complete response and loco-regional control rate was 100% but one patient died of malnutrition due to treatment related toxicity. There were no Grade 3 or 4 xerostomia and all patients had experienced improvement of salivary gland function. Conclusion: 'Simultaneous Modulated Accelerated Radiation Therapy' (SMART) boost intensity-modulated radiotherapy technique allows parotid sparing as evidenced both clinically and by dosimetry. Initial tumor response and loco-regional control was promising. It is clinically feasible. A larger population of patients and a long-term follow-up are needed to evaluate ultimate tumor control and late toxicity.

두경부 종양의 적응방사선치료시 변형영상정합을 이용한 합성선량 평가 (The Evaluation of Composite Dose using Deformable Image Registration in Adaptive Radiotherapy for Head and Neck Cancer)

  • 황철환;고성진;김창수;김정훈;김동현;최석윤;예수영;강세식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권3호
    • /
    • pp.227-235
    • /
    • 2013
  • 적응방사선치료(adaptive radiotherapy, ART)시 획득된 다단계 CT영상으로부터 변형영상정합을 이용하여 전체 처방선량에 대한 주변 정상조직의 합성선량을 획득하고, 각각의 단일 치료계획으로부터 합산되어진 선량을 비교분석하여 임상적 의의를 얻고자 한다. 2011년 5월 1부터 2012년 7월 31일까지 두경부 종양으로 3차원 입체조형치료, 세기변조방사선치료를 시행한 환자 중에서 치료기간 중 종양크기의 변화, 체중의 급격한 감소 등으로 인해 적응방사선치료를 시행한 환자를 대상으로 하였다. 변형영상정합을 이용하여 전체 처방선량에 대한 주변 정상조직의 합성선량을 획득할 수 있었으며, 단일 치료계획으로부터 합산되어진 선량과의 비교에서 하악골($48.95{\pm}3.89$ vs $49.10{\pm}3.55$ Gy), 구강($36.93{\pm}4.03$ vs $38.97{\pm}5.08$ Gy), 이하선($35.71{\pm}6.22$ vs $36.12{\pm}6.70$ Gy), 턱관절($18.41{\pm}9.60$ vs $20.13{\pm}10.42$ Gy)에서 차이의 결과를 보였다. 적응방사선치료시 변형영상정합에 의한 합성선량과 단일 치료계획으로부터 합산되어진 선량과의 유의한 차이를 확인할 수 있었으며, 다단계 CT영상을 사용하는 경우 변형영상정합에 의한 합성선량획득은 주변 정상조직에 대해 보다 정확한 평가가 가능할 것으로 사료된다.

손상위험장기에 인접한 표적 Coverage 개선을 위한 Planning Target Volume 중복 설정에 관한 연구 (Study of overlapping setting up of Planning Target Volume for Improving Target Coverage adjacent Organ At Risk)

  • 이정웅;김보겸;문준기;우헌;이양훈;전창우;이제희
    • 대한방사선치료학회지
    • /
    • 제31권2호
    • /
    • pp.33-41
    • /
    • 2019
  • 목 적: 용적변조회전 방사선치료(Volumetric Modulated Arc Therapy, VMAT)시, Planning Target Volume(PTV)을 중복 설정하여 손상위험장기(Organ At Risk, OAR)에 인접한 PTV Coverage 감소를 개선하기 위한 연구이다. 대상 및 방법: 본원에서 전뇌(Whole Brain), 담낭(Gall Bladder), 직장(Rectum) 방사선치료를 받은 환자를 대상으로 하였으며, PTV 내 Coverage가 부족한 부분에 PTV를 중복 적용한 치료계획과 적용하지 않은 치료계획으로 구성하여 Coverage 변화와 최대선량, 선량균질지수(Homogeneity Index, H.I.), 처방선량지수(Conformity Index, C.I.)를 비교하였으며, 손상위험장기(Organ At Risk, OAR)의 최대선량과 평균선량의 변화 또한 비교하였다. 결 과: 중복하여 적용한 PTV의 Coverage는 모든 환자에게서 증가하였고, 이에 따른 영향으로 전체 Coverage 또한 4명의 환자에게서 증가하였다. PTV의 최대선량은 5명의 환자에게서 증가하였으며, 모든 환자의 선량균질지수와 처방선량지수는 큰 차이를 나타내지 않았다. 수정체의 최대선량은 최대 1.12배 증가하였으나, 뇌줄기의 경우 2명의 환자에게서 최대선량이 감소하였다. 안구의 평균선량은 최대 1.15배 증가하였으며, 양측 이하선의 경우 큰 차이를 나타내지 않았다. 담낭암 환자의 경우 간과 결장의 평균선량은 각각 0.95배, 0.94배 감소하였으며, 십이지장의 평균선량은 큰 차이가 없었다. 직장암 환자의 경우 OAR로 설정한 양측 대퇴골두와 방광 모두 평균선량은 감소하였으며, 전체 MU는 1명을 제외한 4명의 환자에게서 비슷한 수준으로 나타났다. 결 론: OAR의 선량제한을 고려해가면서 적절하게 사용한다면, PTV의 Coverage 개선에 유용한 방법이라 생각한다.

두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석 (Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck)

  • 김대섭;이우석;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.11-19
    • /
    • 2014
  • 목 적 : 최적화 알고리즘에 적용되는 최적화 인자들의 영향을 고려하여, 가장 적합한 인자 값을 도출함으로써 이상적인 치료계획을 쉽게 설계할 수 있도록 하고자 한다. 대상 및 방법 : 본 연구의 세기조절방사선치료에서 선량계산 알고리즘은 PBC(Pencil Beam Convolution)이고, 최적화 알고리즘은 DVO(Dose Volume Optimizer 10.0.28)이다. 두경부 환자의 세기조절방사선치료에서 치료계획용적의 처방선량은 동시에 2.2 Gy와 2.0 Gy가 될 수 있도록 하였다. 치료계획은 6 MV, 7개의 조사야로 역선량계산방법으로 수립하였다. 최적화 알고리즘 인자는 용적선량-조건강도(Priority, Constrain), 선량부 드럼강도(Smooth)로 선정하고, 각 인자들의 변화량에 따른 치료계획의 영향을 분석하였다. 용적선량-조건강도는 기준 조건강도를 정하고, 비율은 같지만 절대 값은 다른 최적화 과정을 실시하였다. 또한 조건강도의 절대 값에 변화에 따른 치료용적과 주변 정상장기들을 평가하였다. 선량부드럼강도는 기준 조건의 단순 변화와 용적선량-조건강도와 관련시킨 변화를 치료계획에 반영시켰다. 치료계획은 처방선량지수(Conformal Index, CI), 처방선량포함지수(Paddick's Conformal Index, PCI), 선량균질지수(Homogeneity Index, HI)와 각 장기의 평균선량으로 평가하였다. 결 과 : 용적선량-조건강도의 비율을 동일하게 하고 절대 값을 변화 시켰을 때 CI값은 다르지만, PCI는 $1.299{\pm}0.006$, HI는 $1.095{\pm}0.004$, D5%/D95%는 $1.090{\pm}1.011$으로 처방선량에 대한 영향은 유사하였다. 이하선의 평균선량은 용적선량-조건강도의 절대 값이 40, 60, 70, 90으로 증가될 때, 67.4, 50.3, 51.2, 47.1 Gy로 감소하였다. 각각의 치료계획에서 선량부드럼강도를 증가시켰을 때, PCI는 $1.338{\pm}0.006$로 증가된 값을 보였다. 결 론 : 용적선량-조건강도는 절대적인 값보다 각 조건의 비율에 따라 최적화 알고리즘에 영향을 주었다. 절대 값이 다르더라도 같은 비율을 유지하면 유사한 치료계획이 수립되었다. 성공적인 치료계획을 수립하기 위해 특히 보호해야할 정상장기의 용적선량-조건강도는 치료용적의 용적선량-조건강도의 50%이상 되어야한다. 선량부드럼강도는 용적선량-조건강도에 따라 비례하여 증가하거나 감소하여야 한다. 단순히 절대 값으로 적용하면 용적선량-조건강도는 그 조건을 충분히 만족시키지 못한다.