• 제목/요약/키워드: Park lighting

검색결과 734건 처리시간 0.028초

KNX/EIB 프로토콜 기반의 통신 모듈 개발 (Development of KNX/EIB-based Communication Module)

  • 박동규;이우석;홍승호;황태영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.420-422
    • /
    • 2007
  • Nowadays, the demand for home networking system is gradually increasing. But most of vendors use their own protocols. KNX/EIB ( European Installation Bus / Konnex) is a standard protocol approved as an European (EN 50090 - EN 13321-1) and a World-wide standard (ISO/IEC 14543). In this study, we develop on/off and dimming lighting control system using BIM. In this system, BIM communicates to micro-controller using PEI(Physical External Interface) communication. And this enables including more KNX/EIB communication objects in lighting control system, and providing lighting control algorithm. The technology in this paper can help to adapt the world-wide standards.

  • PDF

평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구 (The electrical and optical properties of Xe plasma in flat lamp)

  • 백광현;양종경;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

건축주 입장을 고려한 LED조명 프로그램의 한계 분석 연구 (A Study on the Limit Analysis of the LED Lighting Subsidy Program Considering the Perspective of Individual Building Clients)

  • 황성욱;박중성;채우규;이학주;송일근;김정훈
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.18-25
    • /
    • 2013
  • Various DSM (Demand Side Management) programs have been developed and carried out to use the limited energy resources of human-beings reasonably. LED lighting is one of essential DSM programs and the development of technologies is ongoing vigorously. Recently, one-person households have been increased and the electricity consumption pattern is different with conventional households because residents live as a single. On the other hand, owners of the one-person households tend to not prefer to install high efficient appliances due to the cost increasement. Therefore, the existing DSM subsidy programs should be revaluated so that the owners decide to install high efficient appliances.

감성조명 기반 컬러 가시광통신 시스템 (A Color Visible Light Communication Based on Emotional Lighting)

  • 여은모;이대천;김기두;박영일
    • 한국통신학회논문지
    • /
    • 제36권7A호
    • /
    • pp.635-639
    • /
    • 2011
  • 반도체 LED가 조명 인프라를 바꾸게 되면서 동시에 이를 통신에 이용하고자 하는 많은 연구들이 진행 중에 있다. 지금까지는 주로 한 가지 색상의 LED가 가시광통신에 이용되었다. 그러나 감성조명이 점차 중요해지면서 LED를 이용한 가시광통신의 필요성이 커지고 있다. 본 논문에서는 R,G,B 3 색상의 LED를 이용하여 연속적으로 원하는 색상을 구현하면서 데이터를 전송하는 컬러 가시광통신 시스템을 위한 전송방식을 제한하고 실험 결과를 제시하였다.

조명기구를 통한 내부획득열 추정을 위한 고단열실 및 조명기구의 열적 모델링 (Thermal Modeling of Quasi-Adiabatic Room and Lighting Fixture for Estimation of Internal Heat Gain by Luminaires)

  • 박혜리;최은혁;이광식
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.1-12
    • /
    • 2012
  • In order to reduce energy consumption and greenhouse gas emission in building domain, thermal insulation of building is being enhanced. In a well insulated and tightened environment, internal heat gain caused by solar radiation, luminaires, electronic appliances and metabolism can be more important to thermal condition of building. This paper presents mathematical/physical models of quasi-adiabtic room and lighting fixtures using heat balance equation and thermal-electric analogy to quantify and modelize the heat gain due to luminaires. Experimental results are used to identify thermal parameters of theoretical models. And simulation results of models using Matlab/Simulink are conducted to verify the models and to investigate the thermal effect of lighting fixtures into quasi-adiabatic room.

정전탐침법을 사용한 평판형 광원의 제논(Xe)플라즈마 특성 연구 (Xe Plasma property with flat lamp by Langmuir probe)

  • 백광현;양종경;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.572-573
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness. life time. efficiency of flat lamp and plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. When a distance of discharge electrode is 5.5mm and width is 16.5mm. we measured electron temperature and electron density measured with single Langmuir probe in flat lamp. We tested the discharge from 100 Torr to 300 Torr pressure. The pulse type was rectangular with frequency 20kHz and duty ratio was 20%. In result. electron temperature decreases and electron density increased as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

사무소 건물의 에너지 소비 요소별 절감률 분석 (Analysis of Saving Rates according to Energy Consumption Factors in Office Building)

  • 박병일;양인호
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.115-122
    • /
    • 2016
  • In this study, 21 energy reduction factors were selected as architecture, system & operation, and lighting and equipment parts to analyze reduction method of the load occurring in office buildings. Energy consumption simulation was performed. In the architecture part, saving rate (1.53%) of "occupant density" factor was the most efficient. In the system and operation part, saving rate (1.28%) of "interior VAV and exterior FPU type" factor was the most efficient. In case of lighting and equipment part, saving rate (12.42%) of "schedule" factor was the most efficient. In the three parts, saving rate of the lighting and equipment part was 27.32%. This was caused by the "schedule" factor. Saving rates of the architecture part and the system and operation part were 3.39% and 1.20%, respectively.

반사거울 방식을 이용한 중정 내 자연채광 성능 분석 연구 (A Study on Daylighting Performance of an Inner Court with Reflecting Mirror System)

  • 박병윤;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.112-121
    • /
    • 2011
  • To lead lighting inside, design solution and mechenical solution can be used.A inner court and atrium are samples for design solution. However, physical and environmental elements for building design are not taken positively into consideration. So low position of the inner court is difficult to reach lighting performance and a urban landscape gets damaged. On this study, selecting a building with a inner court, best design method is suggested to apply reflecting mirror. building direction, building shape and solar position are considered to deside the setting angle for reflecting mirror. Performance for the setting reflecting mirror is verified through various simulation cases, and is got more lighting performance than the present situation on the building inside.

Design of Path Prediction Smart Street Lighting System on the Internet of Things

  • Kim, Tae Yeun;Park, Nam Hong
    • 통합자연과학논문집
    • /
    • 제12권1호
    • /
    • pp.14-19
    • /
    • 2019
  • In this paper, we propose a system for controlling the brightness of street lights by predicting pedestrian paths, identifying the position of pedestrians with motion sensing sensors and obtaining motion vectors based on past walking directions, then predicting pedestrian paths through the route prediction smart street lighting system. In addition, by using motion vector data, the pre-treatment process using linear interpolation method and the fuzzy system and neural network system were designed in parallel structure to increase efficiency and the rough set was used to correct errors. It is expected that the system proposed in this paper will be effective in securing the safety of pedestrians and reducing light pollution and energy by predicting the path of pedestrians in the detection of movement of pedestrians and in conjunction with smart street lightings.

지능형 LED 조명 시스템의 신뢰성 확보를 위한 유무선 이중망 통합 인터페이스 구현 (Implementation of Integrated Interface based on Wire and Wireless Dual Network for Ensuring the Reliability of Intelligent LED Lighting System)

  • 이운선;박태진;박만곤
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.306-312
    • /
    • 2014
  • The ZigBee communication method, which is the most frequently applied to the LED lighting control system, has drawbacks of low-speed and low-capacity, and the communication failure possibility due to environmental influences is on the rise. Therefore, it is important to secure the communication reliability by applying an integrated interface with a wire-wireless dual-network. This paper developed a communication module, which has a platform converging and combining the ZigBee of USN environments with the PLC of power line communication environments, to implement a dualized communication interface system supporting the wire-wireless integrated protocol, and implemented a wire-wireless networking device and a control system software technology. As a result, it was automatically switched into the PLC communication within 4.4 seconds on average when there was an access failure in the ZigBee communication network, so a reliable communication network was built.