• Title/Summary/Keyword: Park facility

Search Result 2,325, Processing Time 0.024 seconds

Experimental Facility for Measuring the Cooling Performance of a Piezoelectric Fan (피에조 팬 냉각 성능 측정을 위한 실험장치 구축)

  • Oh, Myong Hun;Park, Soo Hyun;Ko, Jae Ik;Choi, Minsuk
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.3
    • /
    • pp.52-58
    • /
    • 2018
  • In this study, an experimental facility has been built to measure the cooling performance of a piezoelectric fan. The facility is composed of a heat source made of $50{\mu}m$ Ni-Cr foil, a piezoelectric fan and a rotary fan for cooling the heat source. For two cases where the foil is vertical or horizontal, the surface temperature on the foil has been measured by an IR camera with and without cooling and the cooling performance of both fans has been analyzed. With cooling by both fans, the rotary fan lowers the surface temperature of the foil as a whole, while the piezoelectric fan lowers the surface temperature at the center of the foil locally. It is also found that the cooling effectiveness of the piezoelectric fan is higher on the horizontal foil than on the vertical foil because the natural convection interferes with the jet from the piezoelectric fan.

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.

Electromagnetic Wave Shielding Effectiveness Measurement Method of EMP Protection Facility (EMP 방호시설의 전자파 차폐효과 측정 방법)

  • Seo, Manjung;Chi, Seongwon;Kim, Youngjin;Park, Woochul;Kang, Hojae;Huh, Changsu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.548-558
    • /
    • 2014
  • EMP(Electromagnetic Pulse) protection facility was evaluated according to standard of shielding effectiveness. To comply with the standard, transmitting antenna was placed on outside of protection facility and receiving antenna was placed on inside of protection facility. However, measurement is impossible that place does not have enough space between protection facility and external concrete structure. In this paper, we performed a various of tests that put transmitting antenna inside the EMP protection facility in order to find out test method for measuring the shielding effectiveness of electromagnetic wave. Transmitting antenna was placed on inside of the EMP protection facility for measuring the shielding effectiveness to compare and analyze the impact of the position regarding to the transmitting and receiving antenna. As a result of test, in case that transmitting antenna was placed on inside of the EMP protection facility, it was found that test frequency range 10 kHz~1 GHz were occurred overall average difference of ${\pm}4$ dB level.

A Study on Status of Use and Facilities importance level evaluation of Neighborhood Park in Industry Complex on the rural - With Special Reference on 4 Local Industry Complex of Cheonan City (농촌 산업단지 내 근린공원의 이용실태 및 시설 평가 연구 - 천안 제 4지방산업단지 내 근린공원을 중심으로 -)

  • Yun, Yo-Sun;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.1
    • /
    • pp.65-72
    • /
    • 2013
  • Neighborhood park has the multiple functions toward quantitative and qualitative improvement of quality of citizen's life. This study is about neighborhood park in 4 Local Industry Complex of Cheonan City. Through this study has intended to analyze the status of use and the importance level of facilities. To reach this goal, this study has analyzed the general information, use and importance level of users through such statistical methods as frequency analysis, regression analysis and reliability analysis. As a result, users has the speciality in the neighborhood park in industry complex. Break area or facilities for the workers should be installed. Not end once installed, but continually improved and more efficient management of park facilities will be made. Also, importance of facilities analysis has the higher in normal or importance. Management and cleanliness is especially higher in importance. Importance for the overall facility was affecting in order the facility design, management, safety, installation number.

A Study on the Establishment of a Aquaculture Farm Facility Management System Using IP-RFID (IP-RFID를 이용한 양식장 시설물 관리시스템 구축방안에 관한 연구)

  • Choi, Hyung-Rim;Park, Byoung-Kwon;Park, Yong-Sung;Lee, Chang-Sup;Choi, Ki-Nam
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.26-27
    • /
    • 2010
  • Illegal aquaculture farms that cause marine pollution and ship accidents are managed and controlled by local organizations, but they experience many difficulties due to the vast waters and insufficient human resources. This study aims to utilize new IP-RFID technology to propose an efficient aquaculture farm facility management system This system attaches Ip-Tags to aquaculture farms that can provide facility information and location in real-time through IP communications. This allows for efficient management of facilities and the restriction of illegal farms. This system can also provide locations of farm facilities that sink to the ocean floor, reducing marine pollution caused by lost farms.

  • PDF

PARAMETRIC STUDIES ON THERMAL HYDRAULIC CHARACTERISTICS FOR TRANSIENT OPERATIONS OF AN INTEGRAL TYPE REACTOR

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Song, Chul-Hwa;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.185-194
    • /
    • 2006
  • Transient operations for an integral type reactor, SMART-P, have been experimentally investigated using a thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), in order to verify the system design and performance of the SMART-P, a pilot plant of SMART. The VISTA facility was subjected to various accident conditions such as feedwater increase and decrease, loss of coolant flow, and control rod withdrawal accidents in order to elucidate the thermal-hydraulic responses following such accidents and finally to verify the system design of the SMARTP. Full functional control logics have been implemented in the VISTA facility in order to control the required control action for an accident simulation. As one of the sensitivity tests to verify the PRHRS performance, the effects of the initial water level in the compensation tank are experimentally investigated. When the initial water level is 16%, the water is quickly drained and nitrogen gas is then introduced into the PRHR system, resulting in deterioration of the PRHRS performance. It is thus found that nitrogen ingression should be prevented to ensure stable PRHRS operation.

A Study on How to Evaluate Appropriate Ventilation Rate of Indoor Facility Handling Hazardous Substances by Their Flammable and Explosive Properties (유해화학물질을 취급하는 실내시설에서의 인화폭발성에 따른 적정 환기량 산정에 대한 연구)

  • Mansu Park;Cheong-Min Seo;Hyo-Soub Yoon;Kyoshik Park
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.293-301
    • /
    • 2024
  • Purpose: Ministry of Environment statistics reveals more than 132 fire·explosion accidents in South Korea between 2014 and 2023. Among them, fire and/or explosion accidents are very impactive in their scale and consequence. This study aims to suggest a new method of reasonable way to calculate the ventilation rate of indoor facility handling hazardous chemicals based on their inflammability. Method: A new method to calculate the ventilation rate is based on the physicochemical properties of the chemicals handled, which is more reasonable compared with the current regulation based only on the floor area of the facility. Result: Considering the physicochemical properties, 178 chemicals based on their inflammability were studied and 168(94%) met the criteria for the current regulation. Some materials have been shown to require too much or too little ventilation rate. Conclusion: Through this study, a reasonable method of calculating the required ventilation rate was proposed. This should be applied to ensure the safety of workers to deal chemicals.

Landscape Design for Integrated Disposal Treatment Facility in Southern Region (남부 광역 생활폐기물 종합처리시설 조경설계)

  • 민권식
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.1
    • /
    • pp.11-22
    • /
    • 2003
  • This landscape design proposal was presented to a design competition for the Incheon-city Southern Region Integrated Disposal Treatment Facility. The site is located in Dongchun-dong, Yeonsu-gu, Incheon. The main design concepts are as follows: First, considering connection of the site with surrounding water, inner sea is designed as an environmentally friendly place and as a leisure-sports theme park in which several sports facilities and relaxing places are arranged. It is also designed for everyone: people of all ages, disabled, workers, visitors and local residents. The design was processed on the basis of survey, analysis of surrounding competing facilities and SWOT analysis. Second, the ecological planting model was developed by analyzing the natural vegetation map in the surrounding area and planted vegetation types in the seaside reclamation area. The model was then applied to the ecological community, park area and roadside trees, so as to harmonize with the local habitat. Third, the project is intended to launch private capital for managing the sports park and golf course. This will enable a entrepreneur to make flexible plans for golf training field that is expected to yield a good financial return. It is expected that this design would serve the local residents as a symbolic, environmentally friendly leisure-sports theme park.

Study for Reducing Safety Distance by Installing Ammunition Storage Facility in Underground (탄약저장시설 지하화에 따른 안전거리 축소방안 연구)

  • Park, Sangwoo;Jun, Jonghoon;Choi, Hangseok;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • With increasing interest in an underground-type ammunition storage facility, several design results have been provided recently. However, since not only experts in the tunnel but also military persons in charge of ammunition have not fully understood the safety distance standard, reliable design results are not being produced. In this study, the effective design method of an underground-type ammunition storage facility was provided by analyzing the current safety distance standard. First, the critical safety distances that dominate the size of construction site for underground-type ammunition storage facilities were evaluated, which are the layout of chambers and the configuration of the entrances. Then, the decreasing effect of inter-chamber distance was studied according to the rock type and the storage density of ammunition. In addition, the method of designing tunnels with parallel lines and two-floors was considered for arranging more chambers while complying with the safety distance standards. In particular, numerical simulations were carried out to determine the satisfaction of the safety distance standards when an underground-type ammunition storage facility is composed of two-floor and the decreasing effect of inter-chamber distance according to the inner explosive pressure reduction. Finally, the method to adjust the size of entrances and the path of pressure were studied for decreasing the safety distance at the entrance.

Price-Sensitivity Measurement of a Forest Welfare Facility (산림복지 인프라 가격결정을 위한 가격민감성 분석)

  • Lee, Sanghyun;Lee, Hoseung;Lee, Juyoung
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.483-491
    • /
    • 2017
  • This study provides basic data for the cost operating strategy of forest welfare infra facilities. We use the Price-Sensitivity Measurement technique (PSM) for a forest welfare infra facility (healing forest, wood camping, forest leisure sport, etc.). In addition, we conduct a survey in the four target locations (Kyung-gi, Kyung-sang, Chung-cheong, and Jeolla) and receive answer from 390. The results show that higher the price of present infra facilities, higher the price sensibility. The forest welfare infra facilities we include are healing forest 1,894 won, wood camping 5,625 won, mtb park 9,530 won, mountain horseback riding 14,556 won, paragliding 20,252 won, mountain ski 3,075won. However, we investigate zip-lines at lower than current price levels.