• Title/Summary/Keyword: Park Facility

Search Result 2,336, Processing Time 0.028 seconds

Structure and Change Pattern of Gijang Mountain Fortress and its Receiving Reservoir (기장산성 집수지의 구조와 변화양상)

  • Hwang, Dae-Il;Jung, Dae-Bong;Park, Jun-Hyun
    • Journal of architectural history
    • /
    • v.22 no.4
    • /
    • pp.35-44
    • /
    • 2013
  • This paper looked into the structure of and changes in the building process of Gijang mountain fortress and its receiving reservoir by analyzing data from an excavation investigation. The structure of the receiving reservoir may be classified into a flat form, stone sheath, floor facility, wall facility, and entry and exit facility. The flat form of the Gijang mountain fortress and receiving reservoir is round. Concerning the sectional form, the wall was obliquely excavated in the trapezoid. As a stone sheath building method, it was built by undertaking a range work of oblong stone materials in a clockwise direction on a stamped soil floor. Then, it was treated with stamping using double layers of gray clay and yellowish brown clay on the floor and the wall. Also, in a space between the stamped layers on the floor, herbal plants and a straw mat were laid for waterproofing as well as to prevent sinking. As an entry and exit facility, two facilities were confirmed symmetrically in the southeast and in the northwest. It is believed that they were built additionally during rebuilding after the initial construction. The building process was revealed to have been carried out in 8 stages. Given the structure and excavated remains, the building period is estimated to be the early to mid 7th century for the initial building, the later 9th to 11th centuries for the primary rebuilding, and the later 16th to early 17th centuries for the secondary rebuilding.

A Study on the Visualization of Facility Data Using Manufacturing Data Collection Standard (제조설비 데이터 수집 표준을 이용한 설비 데이터 시각화에 대한 연구)

  • Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.3
    • /
    • pp.159-166
    • /
    • 2018
  • This paper introduces a manufacturing facility visualization system for the monitoring of smart factories. With the development of technology and the emergence of such terms as the Fourth Industrial Revolution and Industry 4.0, technologies for smart factories are becoming more important. A Manufacturing Execution System that can improve productivity and help decision making by monitoring production plants in real-time is one of the key technologies for smart factories. The application of digital twin technology for more accurate monitoring technology is also an important issue. However, digital twin implementations require an integrated infrastructure that can integrate facility data from multiple manufacturers. Therefore, this paper designs and develops a visualization program that can verify real-time information of facilities using data collection system based on international standard protocol for heterogeneous collection and monitoring of facility data. This allows a factory to consolidate equipment data from multiple manufacturers and to view them in real-time.

Contribution of thermal-hydraulic validation tests to the standard design approval of SMART

  • Park, Hyun-Sik;Kwon, Tae-Soon;Moon, Sang-Ki;Cho, Seok;Euh, Dong-Jin;Yi, Sung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1537-1546
    • /
    • 2017
  • Many thermal-hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor) design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop) has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium) safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test) facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant) performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test) facility to evaluate the safety injection performance and to validate the thermal-hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux) test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop) facility to construct a database from the $5{\times}5$ rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio) model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

The Development of Emission Factors of Greenhouse Gas from Middle and Small-Scaled RPF Incineration Facility by Concentration Measurement and Fuel Composition (농도실측 및 연료 성분조성에 의한 중소형 RPF 소각시설의 온실가스 배출계수 개발)

  • Na, Kyung-Ho;Song, Il-Seok;Choi, Si-Lim;Yoo, Jae-In;Park, Ik-Beom;Kim, Jin-Gil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.423-434
    • /
    • 2012
  • This study was carried out to develop for the emission factor of greenhouse gas (GHG) from medium and smallscaled incineration facility using RPF which is considering as a part of renewable energy in UNFCC. The actual concentration of the exhaust gas and the fuel composition of RPF were measured for the calculation of GHG emission factor in RPF incinerators, and were compared with the IPCC guideline. The $CO_2$ and $N_2O$ emission factors by the actual concentration of exhaust gas were $2.3575{\pm}1.0070tCO_2/tRPF$ and $0.0014{\pm}0.0014tN_2O/tRPF$ respectively. Also, $CO_2$ emission factor by the RPF composition was $2.7057{\pm}0.0540tCO_2/tRPF$. The GHG emission factor per energy by the actual concentration was $83.0867{\pm}26.0346tCO_2e/TJ$ which showed higher consistency with the GHG emission factor ($80.3967tCO_2e/TJ$) of waste plastic in the IPCC guideline (2006b). The $CO_2$ and $N_2O$ emission factor calculated in this study is considered as a meaningful data for GHG emission factor of RPF incineration facility because of not being developed in ROK.

A Study on Characteristics of Space Composition for Exhibition and Convention Facilities - Focused on the Function Distribution and Area Composition - (전시컨벤션 시설의 공간구성적 특성에 관한 연구 - 기능배분과 면적구성을 중심으로 -)

  • Park, Tae-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.203-210
    • /
    • 2013
  • The purpose of this study was to investigate and analyze the function and scale on aspect of construction planning with examples of exhibition and convention facilities constructed recently in domestic and foreign area. Also, it was to provide the result for basic data for construction planning and architecture of similar facilities constructed later. The study methodles, but they had characteristics to use the space with compound purpose for exhibition, conference, etc through installing multi-purpose hall. Finally, for effective construction planning of exhibition and convention facilities, it was required to decrease the ratio of common area gradually and derive rationalization of whole space composition by deriving complexity of function rather than planning of single purpose of each facility for exhibition and conference function. was to analyze the characteristics of construction planning for composition and scale of exhibition, conference, public use, support, maintenance functions, etc and placement composition of unit rooms by each floor on the basis of internal area of exhibition and convention facility in Korea and Japan. As the result of analyzing 10 examples(K1~J5), the placement of auditorium and multi-purpose hall was affected according to location of exhibition room and conference room in the composition of unit rooms by each floor and the installment ratio of support facility in Korean examples was higher than in Japanese examples. In case of facility scale, the Japanese examples were overall small in the whole scale relatively to Korean examp.

Preparation and Management of the Input Data for the Safety Assessment of Low- and Intermediate-level Radioactive Waste Disposal Facility in Korea (중·저준위 방사성폐기물 처분시설 안전성평가를 위한 입력데이터 설정 및 관리에 대한 고찰)

  • Park, Jin Beak;Kim, Hyun-Joo;Lee, Dong-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.345-361
    • /
    • 2014
  • The systematic quality assurance activities on documents of the safety assessment are required for the safety case of the low- and intermediate-level radioactive waste disposal facility. In this paper, quality assurance system focused on the input data including the site characterization, groundwater flow, system design and monitoring are prepared and discussed. Rule for the input data selection is suggested and applied for the safety assessment which is based on the in-situ/experiment observations, final facility design and waste pileup plan, engineered barrier, field monitoring, recent biosphere, and radionuclide inventory. The reduction of data uncertainty will be expected to contribute to the safety of disposal facility further.

A Measurement on the Economic Effects of Facility Modernization Policy for Improvement of Fruits Quality (과수고품질 시설현대화사업의 정책성과 측정 연구)

  • Park, Mi-Sung;Kim, Bae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.581-586
    • /
    • 2017
  • The facility modernization policy has been established to improve fruits quality and to increase fruits yield per acreage. The fruit production quantity of farms joined in the policy was increased. Therefore, many fruit farms want to participate in the policy. The government has subsidized fruit farms to modernize their facilities such as rain proof, drainage way, frost proof, etc. This study analyzes the performance of the facility modernization policy focused on apple, eastern pear, and grape cultivation sector. One hundred apple farms, one hundred eastern pear farms, and 91 grape farms were surveyed. The performance of the policy was reviewed using analytical technique such as Covariate Matching and Propensity Score Matching and several policy implications were suggested.

Characteristics of compost produced in food waste processing facility (음식물류 폐기물 퇴비화시설에서 생산된 퇴비품질 특성)

  • Lee, Chang-hoon;Park, Seong-jin;Kim, Myeong-sook;Yun, Sun-gang;Ko, Byong-gu;Lee, Deog-bae;Kim, Sung-chul;Oh, Taek-Keun
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.3
    • /
    • pp.177-181
    • /
    • 2015
  • Food waste has been widely considered as a recycling resource to be applied to agricultural lands due to the effects of organic matter and nutrient for plant productivity. but the maturity and salt concentration in the compost produced from food waste processing facilities should be considered firstly, which was little information on compost quality produced from food waste treatment facility. In this study, we examined actual situation of food waste processing facility on the composting of food waste and evaluated the characteristics of composts produced from food waste processing facilities. The quality of composts was analyzed on the basis of the criteria of fertilizer processing manual. The 46% of food waste treatment facility registered composting produced actually the compost mixed with food waste or animal waste. The compost maturity and salt concentration as indicators of the quality of compost were not met 46.8% of composts collected from food waste processing facilities to the criteria of fertilizer processing manual. Also, 15.6%(moisture) were not satisfied with the criteria. In conclusion, the compost produced from food waste processing facilities is firstly required with better compost maturity and reduced salt concentration in order to use to agricultural lands as an amendment.

A Study on Status Definition and Diagnostic Algorithm for Autonomic Control of Manufacturing Facilities (제조설비 자율제어를 위한 상태 정의 및 진단 알고리즘에 대한 연구)

  • Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.227-234
    • /
    • 2020
  • This paper introduces the state definition and diagnostic algorithm for autonomic control of manufacturing facilities. Smart factory systems through cyber-physical systems and digital twin technology are increasing the productivity and stability of existing manufacturing plants, which has become an issue recently. A Smart factory system is one of the key technologies that make up a smart factory system, to improve productivity, enable workers to make better decisions, and to control abnormal process flows. However, performing an autonomic control process based on large number of integrated plat data requires significant advance work. Therefore, in this paper, we define an abstracted facility state for manufacturing facility autonomic control and propose an algorithm to diagnose the current state. This makes the autonomic control process simpler by autonomic control based on the facility status rather then integrated facility data.

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.