• Title/Summary/Keyword: Parametric Method

Search Result 2,435, Processing Time 0.031 seconds

Facial Expression Control of 3D Avatar using Motion Data (모션 데이터를 이용한 3차원 아바타 얼굴 표정 제어)

  • Kim Sung-Ho;Jung Moon-Ryul
    • The KIPS Transactions:PartA
    • /
    • v.11A no.5
    • /
    • pp.383-390
    • /
    • 2004
  • This paper propose a method that controls facial expression of 3D avatar by having the user select a sequence of facial expressions in the space of facial expressions. And we setup its system. The space of expression is created from about 2400 frames consist of motion captured data of facial expressions. To represent the state of each expression, we use the distance matrix that represents the distances between pairs of feature points on the face. The set of distance matrices is used as the space of expressions. But this space is not such a space where one state can go to another state via the straight trajectory between them. We derive trajectories between two states from the captured set of expressions in an approximate manner. First, two states are regarded adjacent if the distance between their distance matrices is below a given threshold. Any two states are considered to have a trajectory between them If there is a sequence of adjacent states between them. It is assumed . that one states goes to another state via the shortest trajectory between them. The shortest trajectories are found by dynamic programming. The space of facial expressions, as the set of distance matrices, is multidimensional. Facial expression of 3D avatar Is controled in real time as the user navigates the space. To help this process, we visualized the space of expressions in 2D space by using the multidimensional scaling(MDS). To see how effective this system is, we had users control facial expressions of 3D avatar by using the system. As a result of that, users estimate that system is very useful to control facial expression of 3D avatar in real-time.

The Study on the Trends of Resecarch Papers Published in the Journal of Oriental Medical Surgery?phthalmology & Otolaryngology Society. (大韓眼耳鼻咽喉皮膚科學會誌에 揭載된 硏究論文들의 傾向性 考察)

  • Kwon, Kang;Seo, Hyung-sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.1
    • /
    • pp.1-32
    • /
    • 2003
  • Objectives: This study was carried out to analyze and understand the trends of research papers published In the Journal of Oriental Medical Surgery?phthalmology & Otolaryngology Society(JOMSOOS). Methods: We studied the 308 research papers that had been published in JOMSOOS from 1988 Vol. 1. No. 1. to 2002 Vol. 15. No. 2. Our study was developed through the four stages in order to analyze the papers; 1) we analyzed all the papers overall to classify them into three categories; original article. review article and case report. 2) we classified the original articles in terms of methodology. 3) we also analyzed the case reports according to the sort of disease each paper dealt with. 4) we had another statistical approach to each paper to figure out the distribution of diagnoses in detail. Results: We have got the following outcomes from our analysis of the papers in terms of the four stages. 1. Overall Analysis. 1) Classification of 308 research papers between 1988 and 2002: 137 original articles(44.48$\%$), 111 review articles(36.04$\%$), 56 case reports(18.18$\%$). 2) Used language: Korean(99.03$\%$). English(0.97$\%$). 3) The Number of Authors: 2 persons(42.86$\%$). 3 persons(29.87$\%$), 1 person(14.61$\%$). 2. Original Article Analysis 1) Classification of 137 original articles in terms of methodology: 90 experimental studies(65.69$\%$)46 descriptive studies(33.58$\%$), 1 analytic study(0.73$\%$). 2) Classification of the original articles according to the use of statistical methods: No statistical methods(36.42$\%$), Descriptive methods only(1.99$\%$), Not defined(23.18$\%$), t-test(24.50$\%$), ANOVA(3.97$\%$), Multiple comparison(2.65$\%$), Non-parametric test(2.65$\%$), Other methods(1.32$\%$). 3) Classification of 46 descriptive articles in terms of diseases: otorhinolaryngology(43.48$\%$), dermatology(23.91$\%$), ophthalmology(13.04$\%$), facial palsy(13.04$\%$). 4) Classification of descriptive articles in terms of the number of patients: the highest was 'more than 26 but less than 50 persons'(19 articles - 41.30$\%$). 5) Classification of descriptive articles in terms of the period for patients observation: the highest was the time 'more than 9 but less than 12 months(34.78$\%$)' Out of the 34.78$\%$, the number of articles with the patients observed for more than 12 months was 13(28.26$\%$). 3. Case Report Analysis 1) Classification of 56 case reports in terms of the sort of disease: dermatology(44.64$\%$), ophthalmology(19.64$\%$), otorhinolaryngology(14.29$\%$), facial palsy(8.93$\%$). 2) Classification in terms of the number of patients: 1 person(50$\%$), 3 persons(16.07$\%$), 2 persons(14.29$\%$). 4. Diagnosis Distribution of Each Disease. 1) Studies regarding ophthalmology : the percentage of 'strabismus' cases was the highest(33.33$\%$). 2) Studies regarding otorhinolaryngology : nasal inflammation(34.48$\%$), tinnitus(20.69$\%$). 3) Studies regarding dermatology: the percentage of 'allergic skin disease' was the highest(33.33$\%$). Conclusions: We analyzed the trends of research papers that have been published in JOMSOOS in detail. We came to understand the trends of the research through this study. However, we acknowledge that we only adopted the quantitative method out of various possible analysis methods. For further studies, we strongly urge to adopt the qualitative methods as well.

  • PDF

Effects of Polar Literacy Education Program for Elementary and Middle School Students (초·중학생 대상 극지 소양 교육 프로그램의 효과)

  • Sueim Chung;Donghee Shin
    • Journal of The Korean Association For Science Education
    • /
    • v.43 no.3
    • /
    • pp.209-223
    • /
    • 2023
  • This study was conducted to evaluate the effectiveness of a polar literacy education program for elementary and middle school students, and to derive implications for new education to respond to climate change. We developed modular education programs based on the seven principles of polar literacy established by the Polar-ICE team. We divided them into two courses, one emphasizing science concepts and another emphasizing humanities and sociological issues. We then selected and structured detailed programs suitable for the two courses. These two courses were applied to 26 elementary and middle school students for approximately 69 hours in a Saturday science class hosted by the Department of Science Education at a university in Seoul. The 26 students were divided into three groups. Two groups completed the science education program for polar literacy and a humanities and social studies education program for polar literacy, respectively. The third group, the control group, received general science education unrelated to polar literacy. Before and after running the programs, all three groups responded to a polar literacy test and questionnaires that used vocabulary and presented scenes associated with polar regions. The test results were expressed using Wilcoxon signed ranks, which is a non-parametric test method, and improvements made upon completion of the program were analyzed. From a cognitive aspect, all three groups showed improvement after completing the program in the knowledge area; however, the experimental groups showed a greater degree of improvement than the control group, and there was a clear difference in the contents or materials explicitly covered. From an affective aspect, the difference between before and after the program was minor, but the group that focused on humanities and social issues showed a statistically significant improvement. Regarding changes in polar imagery, the two experimental groups tended to diverge from monotonous images to more diverse images compared to the control group. Based on the above results, we suggested methods to increase the effectiveness of polar literacy education programs, the importance of polar literacy as appropriate material for scientific thinking and earth system education, measures to improve attitudes related to the polar region, and the need to link to school curriculums.

A Study of Anomaly Detection for ICT Infrastructure using Conditional Multimodal Autoencoder (ICT 인프라 이상탐지를 위한 조건부 멀티모달 오토인코더에 관한 연구)

  • Shin, Byungjin;Lee, Jonghoon;Han, Sangjin;Park, Choong-Shik
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.3
    • /
    • pp.57-73
    • /
    • 2021
  • Maintenance and prevention of failure through anomaly detection of ICT infrastructure is becoming important. System monitoring data is multidimensional time series data. When we deal with multidimensional time series data, we have difficulty in considering both characteristics of multidimensional data and characteristics of time series data. When dealing with multidimensional data, correlation between variables should be considered. Existing methods such as probability and linear base, distance base, etc. are degraded due to limitations called the curse of dimensions. In addition, time series data is preprocessed by applying sliding window technique and time series decomposition for self-correlation analysis. These techniques are the cause of increasing the dimension of data, so it is necessary to supplement them. The anomaly detection field is an old research field, and statistical methods and regression analysis were used in the early days. Currently, there are active studies to apply machine learning and artificial neural network technology to this field. Statistically based methods are difficult to apply when data is non-homogeneous, and do not detect local outliers well. The regression analysis method compares the predictive value and the actual value after learning the regression formula based on the parametric statistics and it detects abnormality. Anomaly detection using regression analysis has the disadvantage that the performance is lowered when the model is not solid and the noise or outliers of the data are included. There is a restriction that learning data with noise or outliers should be used. The autoencoder using artificial neural networks is learned to output as similar as possible to input data. It has many advantages compared to existing probability and linear model, cluster analysis, and map learning. It can be applied to data that does not satisfy probability distribution or linear assumption. In addition, it is possible to learn non-mapping without label data for teaching. However, there is a limitation of local outlier identification of multidimensional data in anomaly detection, and there is a problem that the dimension of data is greatly increased due to the characteristics of time series data. In this study, we propose a CMAE (Conditional Multimodal Autoencoder) that enhances the performance of anomaly detection by considering local outliers and time series characteristics. First, we applied Multimodal Autoencoder (MAE) to improve the limitations of local outlier identification of multidimensional data. Multimodals are commonly used to learn different types of inputs, such as voice and image. The different modal shares the bottleneck effect of Autoencoder and it learns correlation. In addition, CAE (Conditional Autoencoder) was used to learn the characteristics of time series data effectively without increasing the dimension of data. In general, conditional input mainly uses category variables, but in this study, time was used as a condition to learn periodicity. The CMAE model proposed in this paper was verified by comparing with the Unimodal Autoencoder (UAE) and Multi-modal Autoencoder (MAE). The restoration performance of Autoencoder for 41 variables was confirmed in the proposed model and the comparison model. The restoration performance is different by variables, and the restoration is normally well operated because the loss value is small for Memory, Disk, and Network modals in all three Autoencoder models. The process modal did not show a significant difference in all three models, and the CPU modal showed excellent performance in CMAE. ROC curve was prepared for the evaluation of anomaly detection performance in the proposed model and the comparison model, and AUC, accuracy, precision, recall, and F1-score were compared. In all indicators, the performance was shown in the order of CMAE, MAE, and AE. Especially, the reproduction rate was 0.9828 for CMAE, which can be confirmed to detect almost most of the abnormalities. The accuracy of the model was also improved and 87.12%, and the F1-score was 0.8883, which is considered to be suitable for anomaly detection. In practical aspect, the proposed model has an additional advantage in addition to performance improvement. The use of techniques such as time series decomposition and sliding windows has the disadvantage of managing unnecessary procedures; and their dimensional increase can cause a decrease in the computational speed in inference.The proposed model has characteristics that are easy to apply to practical tasks such as inference speed and model management.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF