• Title/Summary/Keyword: Parameters Sensitivity

Search Result 2,066, Processing Time 0.038 seconds

Fog Detection over the Korean Peninsula Derived from Satellite Observations of Polar-orbit (MODIS) and Geostationary (GOES-9) (극궤도(MODIS) 및 정지궤도(GOES-9) 위성 관측을 이용한 한반도에서의 안개 탐지)

  • Yoo, Jung-Moon;Yun, Mi-Young;Jeong, Myeong-Jae;Ahn, Myoung-Hwan
    • Journal of the Korean earth science society
    • /
    • v.27 no.4
    • /
    • pp.450-463
    • /
    • 2006
  • Seasonal threshold values for fog detection over the ten airport areas within the Korean Peninsula have been derived from the data of polar-orbit Aqua/Terra MODIS and geostationary GOES-9 during a two years. The values are obtained from reflectance at $0.65{\mu}m\;(R_{0.65})$ and the difference in brightness temperature between $3.7{\mu}m\;and\;11{\mu}m\;(T_{3.7-11})$. In order to examine the discrepancy between the threshold values of two kinds of satellites, the following four parameters have been analyzed under the condition of daytime/nighttime and fog/clear-sky, utilizing their simultaneous observations over the Seoul metropolitan area: brightness temperature at $3.7{\mu}m$, the temperature at $11{\mu}m,\;the\;T_{3.7-11}$ for day and night, and the $R_{0.65}$ for daytime. The parameters show significant correlations (r<0.5) in spatial distribution between the two kinds of satellites. The discrepancy between their infrared thresholds is mainly due to the disagreement in their spatial resolutions and spectral bands, particularly at $3.7{\mu}m$. Fog detection from GOES-9 over the nine airport areas except the Cheongju airport has revealed accuracy of 60% in the daytime and 70% in the nighttime, based on statistical verification. The accuracy decreases in foggy cases with twilight, precipitation, short persistence, or the higher cloud above fog. The sensitivity of radiance and reflectance with wavelength has been analyzed in numerical experiments with respect to various meteorological conditions to investigate optical characteristics of the three channels.

An Analysis on Characteristics of Turbulence Energy Dissipation Rate from Comparison of Wind Profiler and Rawinsonde (연직바람관측장비와 레윈존데의 비교를 통한 난류 에너지 감소률의 특성 분석)

  • Kang, Woo Kyeong;Moon, Yun Seob;Jung, Ok Jin
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.448-464
    • /
    • 2016
  • The purpose of this study is to optimize the parameters related to consensus coherency within the PCL 1300, the operating program of wind profiler, from a validation of wind data between rawinsonde and wind profiler at Chupungryeong ($36^{\circ}13^{\prime}$, $127^{\circ}59^{\prime}$) site in Korea. It is then to analyze the diurnal and seasonal characteristics of the turbulence energy dissipation rate (${\varepsilon}$) in clear and rainy days from March 2009 to February 2010. In comparison of the wind data between wind profiler and rawinsonde during April 22-23, 2010, it was shown in a big error more than $10ms^{-1}$ over the height of 3,000 meters in the zonal (u) and meridional (v) wind components. When removing more than $10ms^{-1}$ in each wind speed difference of u an v components between the two instruments, the correlation coefficients of these wind components were 0.92 and 0.88, respectively, and the root mean square errors were 3.07 and $1.06ms^{-1}$. Based on these results, when the data processing time and the minimum available data within the PCL 1300 program were adjusted as 30 minutes and 60%, respectively, the bias errors were small. In addition, as a result of an analysis of sensitivity to consensus coherency of u and v components within the PCL1300 program, u components were underestimated in radial coherency, instantaneous and winbarbs coherency, whereas v components were overestimated. Finally by optimizing parameters of the PCL1300 program, the diurnal and seasonal means of ${\varepsilon}$ at each height were higher in rainy days than those in clear days because of increasing in the vertical wind speed due to upward and downward motions. The mean ${\varepsilon}$ for clear and rainy days in winter was lower than those of other seasons, due to stronger horizontal wind speed in winter than those in other seasons. Consequently, when the turbulence energy dissipation rates in the vertical wind speed of more than ${\pm}10cm\;s^{-1}$ were excluded for clear and rainy days, the mean ${\varepsilon}$ in rainy days was 6-7 times higher than that in clear days, but when considering them, it was 4-5 times higher.

An epidemiological study of human paragonimiasis by means of micro-ELISA (면역효소진단법을 이용한 폐흡충증 유행의 역학조사)

  • 조승열;이동근강신영김석일
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.246-256
    • /
    • 1983
  • As epidemiological parameters of human paragonimiasis, the positive rates of intradermal test and the sputum/stool ekaminations have long been employed in population surveys. However, both the specificity of the intradermal test and the sensitivity of sputumjstool examination have been gradually declined as the endemicity was lowered; thus the gap between above two parameters widened. In such context, the development of a new epidemiologic parameter or tool which makes it possible to accurately discriminate the active paragonimiasis cases was necessary. In the present study, the detection rate of Paragonimus-speclac IgG antibody by micro-ELISA was evaluated as an indicator of epidemiologic status of human paragonimiasis in a population. A total of 4, 285 students and inhabitants living in Bukpyeong Myeon and Bukil Myeon, Haenam Gun, Jeonlanam Do was surveyed in October, 1983 by intradermal test first. Out of them, 244 cases (5.7%) were found positively reacted to VBS antigen of F. westermani. Out of 168 positive reactors, 7 cases (4.2%) were egg positive either by two times of sputum examination or by one stool examination. That indicated that only 0. 16% of total surveyed were confirmed as active paragonimiasis by egg detection. When sera collected from 239 positive reactors of Intradermal test were tested by micro-ELISA for their specific IgG antibody, 40 cases(16.7%) were found to be positive. All of 7 egg positive cases were again positive for specific IgG antibody. Among remaining 232 intradermal test positive cases, 33 cases were positive for IgG antibody. In contrast to those, none of 42 positive reactors to intradermal test for Cloncrchis and of 128 intradermal test negative cases showed positive for Paragcnimus-specIfic IgG antibody. The rate of specific IgG antibody as detected by micro-ELISA appeared to be increased with the wheal size of the intradermal test. When the wheal sixte was over 13mm in diameter, about 50% of them were positive for specific IgG antibody. Thirty-one specific antibody positive cases were clinically evaluated by laboratory examinations (repeated sputum examination, peripheral eosinophil count and chest roentgenogram) and by history taking. Out of them 24 cases were associated with one or more positive laboratory findings: thus considered as active paragonimiasis cases. Out of 7 lab. finding-free cases 3 revealed past history of typical paragonimiasis symptoms, suggesting that they were in chronic or in convalescent stages. The remaining 4 cases were considered as either mild or ectopic infection cases; the possibility of cross-reaction with other helminthiases could not be ruled out. From the above results, it was inferred that the detection of Paragonimus-specIfic IgG antibody by micro-ELISA was very much helpful in detecting the active cases as well as in proper evaluation of the endemicity of human paragonimiasis in a population. The convenience of mass haildling of sera in micro-ELISA was considered another superiority as an epidemiologic tool.

  • PDF

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Water Quality in a Drainage System Discharging Groundwater from Sangdae-ri Water Curtain Cultivation Area near Musimcheon Stream, Cheongju, Korea (무심천 인근 상대리 수막재배지에서 지하수 사용 후 배출되는 최종 배수로 물의 수질 특성)

  • Moon, Sang-Ho;Kim, Yongcheol;Hwang, Jeong
    • Economic and Environmental Geology
    • /
    • v.48 no.5
    • /
    • pp.409-420
    • /
    • 2015
  • The Sangdae-ri riverside around Musimcheon stream, flowing through Gadeok-myon of Cheongju City, is one of the representative strawberry fields employing water curtain cultivation (WCC) in Korea. In this area, annual groundwater use for WCC has been calculated by a few methods. On the assumption that all the water flowing through the final ditch may be mostly composed of groundwater, the discharge rate in it can be used as a good proxy for assessing the groundwater use. However, in the study area, the final ditch was set up in an unpaved state near and parallel to Musimcheon stream. Under such circumstances, the drainwater is likely to be influenced by infiltration and/or inflow of nearby stream. Hence, we examined whether or not stream water has influenced water flowing out through the final ditch in respect of ion concentrations or field parameters such as T, pH and electrical conductivity (EC) values. The period of measuring field parameters and sample collection was from February 2012 through February 2015. The drainwater in the final ditch did not show the average quality of groundwater, but similar quality of stream water in respect of pH, EC, ion contents and water type. From this, it is suggested that measuring the flow rate of the final ditch should not be directly used for assessing groundwater use in the study area. In addition, because of its sensitivity to ambient temperature, water temperature proved not to be appropriate for estimating the interaction between ditch and stream. For accuracy, additional methods will be needed to calculate mixing ratios between stream and ground water within drainage system.

Estimation of Reliability of Real-time Control Parameters for Animal Wastewater Treatment Process and Establishment of an Index for Supplemental Carbon Source Addition (가축분뇨처리공정의 자동제어 인자 신뢰성 평가 및 적정 외부탄소원 공급량 지표 확립)

  • Pak, JaeIn;Ra, Jae In-
    • Journal of Animal Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.561-572
    • /
    • 2008
  • Responses of real-time control parameters, such as ORP, DO and pH, to the conditions of biological animal wastewater treatment process were examined to evaluate the stability of real-time control using each parameter. Also an optimum index for supplemental carbon source addition based on NOx-N level was determined under a consideration of denitrification rate by endogenous respiration of microorganism and residual organic matter in liquor. Experiment was performed with lab-scale sequencing batch reactor(SBR) and working volume of the process was 45L. The distinctive nitrogen break point(NBP) on ORP-and DO-time profiles, which mean the termination of nitrification, started disappearing with the maintenance of low NH4-N loading rate. Also the NBP on ORP-and DO-time profiles was no longer observed when high NOx-N was loaded into the reactor, and the sensitivity of ORP became dull with the increase of NOx-N level. However, the distinctive NBP was constantly occurred on pH(mV)-time profile, maintaining unique profile patterns. This stable occurrence of NBP on pH(mV)-time profile was lasted even at very high NOx-N:NH4-N ratio(over 80:1) in reactor, and the specific point could be easily detected by tracking moving slope change(MSC) of the curve. Revelation of NBP on pH(mV)-time profile and recognition of the realtime control point using MSC were stable at a condition of over 300mg/L NOx-N level in reactor. The occurrence of distinctive NBP was persistent on pH(mV)-time profile even at a level of 10,000mg/L STOC(soluble total organic carbon) and the recognition of NBP was feasible by tracing MSC, but that point on ORP and DO-time profiles began to disappear with the increase of STOC level in reactor. The denitrfication rate by endogenous respiration and residual organic matter was about 0.4mg/L.hr., and it was found that 0.83 would be accepted as an index for supplemental carbon source addition when 0.1 of safety factor was applied.

Diagnostic Efficacy of FDG-PET in Solitary Pulmonary Nodule (고립성폐결절에서 FDG-PET의 진단적 유용성)

  • Kim, Woo-Jin;Yim, Jae-Joon;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1263-1270
    • /
    • 1997
  • Background : Differentiation of malignity and benignity is crucial for management of solitary pulmonary nodule(SPN). Clinical parameters such as patient's age, nodule size, smoking history, doubling time, typical calcification in X-ray and CT findings have been reported as helpful in this purpose. However, in most cases, these parameters are not conclusive. Glucose metabolism is increased in cancer tissues including lung cancer tissues. After uptake of 2-[F-18]-fluoro-2-deoxy-D-glucose(FDG), the glucose analogue, by cancer cell, FDG is trapped in the cell without further metabolism after phosphorylation. Thus, hypermetabolic focus in FDG-positron emission tomography (PET) imaging suggest malignancy. We evaluated the diagnostic efficacy of FDG-PET imaging in distinguishing malignant and benign SPN. Methods : We evaluated 28 patients with SPN from Jan. 1995 to Jan. 1997. CT scan of chest and whole-body FDG-PET imaging were performed in all patients. Histologic diagnosis was confirmed by transthoracic fine needle aspiration and biopsy, bronchoscopic biopsy and open thoracotomy. Results : Of the 28 SPN's, 22 nodules were malignant and 6 nodules were benign. FDG-PET imaging diagnosed all malignant nodules correctly as positive, and diagnosed 4 of 6 benign nodules correctly as negative. One tuberculous granuloma and one aspergilloma showed hypennetabolic focus and were diagnosed falsely positve with FDG-PET imaging. In the diagnosis of SPN with FDG-PET, sensitivity and specificity were 100% and 66.7%, positive predictive value and negative predictive value were 92% and 100%. Conclusion : FDG-PET imaging is highly useful noninvasive diagnostic tool in distinguishing between malignant SPN and benign SPN.

  • PDF

Differences in the Clinical Characteristics of Children with Urinary Tract Infections Based on the Results of $^{99m}Tc$-Dimercaptosuccinic Acid Renal Scanning (요로감염 소아에서 입원 초기 시행한 DMSA 신 스캔 결과에 따른 임상양상의 차이에 대한 연구: DMSA 신 스캔의 임상적 의미)

  • Kim, Dong Ouk;Lee, Sang Min;Lee, Jeong Bong;Ko, Young Bin;Kim, Su Jin
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • Purpose: The $^{99m}Tc$-Dimercaptosuccinic acid (DMSA) renal scan is used primarily for the diagnosis of renal scarring and acute pyelonephritis in children with urinary tract infections (UTI). This study aimed to evaluate clinical differences based on the positive or negative results of DMSA scans and kidney ultrasonography (US) in pediatric UTI. Method: We retrospectively reviewed 142 pediatric patients with UTI who were admitted to Myongji Hospital from January 2004 to December 2012. We performed a comparative analysis of clinical parameters such as age, sex, white blood cell (WBC) count, neutrophil count, blood urea nitrogen (BUN) level, creatinine (Cr) level, C-reactive protein (CRP) level, and durations of hospitalization and fever, grouped by the results of the DMSA scans and kidney US. Results: The mean age of the patients was $33.8{\pm}48.3$ months, and 78 (55%) were male. Fifty-two patients had abnormal DMSA findings, and 71 patients had abormal kidney US findings (test positive groups). In the DMSA scan positive group, there were significant differences in age, WBC counts, neutrophil counts, CRP level, BUN level, Cr level, hospitalization duration, number of abnormal findings on kidney US, and incidence of vesicoureteral reflux (VUR) compared with the scan negative group. The kidney US positive group had significant differences in age, neutrophil count, CRP level, BUN level, Cr level, hospitalization duration, number of abnormal findings on the DMSA scans, and more frequent VUR compared with the US negative group. Conclusion: Our data suggest that there were no major differences in clinical parameters based on the results of the DMSA scans compared with kidney US in pediatric UTI. However, as kidney US and DMSA scan were performed to predict VUR, the sensitivity and negative predictive value was increased.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

The Usefulness of Dyspnea Rating in Evaluation for Pulmonary Impairment/Disability in Patients with Chronic Pulmonary Disease (만성폐질환자의 폐기능손상 및 장애 평가에 있어서 호흡곤란정도의 유용성)

  • Park, Jae-Min;Lee, Jun-Gu;Kim, Young-Sam;Chang, Yoon-Soo;Ahn, Kang-Hyun;Cho, Hyun-Myung;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.204-214
    • /
    • 1999
  • Background: Resting pulmonary function tests(PFTs) are routinely used in the evaluation of pulmonary impairment/disability. But the significance of the cardiopulmonary exercise test(CPX) in the evaluation of pulmonary impairment is controvertible. Many experts believe that dyspnea, though a necessary part of the assessment, is not a reliable predictor of impairment. Nevertheless, oxygen requirements of an organism at rest are different from at activity or exercising, and a clear relationship between resting PFTs and exercise tolerance has not been established in patients with chronic pulmonary disease. As well, the relationship between resting PFTs and dyspnea is complex. To investigate the relationship of dyspnea, resting PFTs, and CPX, we evaluated the patients of stabilized chronic pulmonary disease with clinical dyspnea rating(baseline dyspnea index, BDI), resting PFTs, and CPX. Method: The 50 patients were divided into two groups: non-severe and severe group on basis of results of resting PFTs(by criteria of ATS), CPX(by criteria of ATS or Ortega), and dyspnea rating(by focal score of BDI). Groups were compared with respect to pulmonary function, indices of CPX, and dyspnea rating. Results: 1. According to the criteria of pulmonary impairment with resting PFTs, $VO_2$max, and focal score of BDI were significantly low in the severe group(p<0.01). According to the criteria of $VO_2$max(ml/kg/min) and $VO_2$max(%), the parameters of resting PFTs, except $FEV_1$ were not significantly different between non-severe and severe(p>0.05). According to focal score($FEV_1$(%), FVC(%), MW(%), $FEV_1/FVC$, and $VO_2$max were significantly lower in the severe group(p<0.01). However, in the more severe dyspneic group(focal score<5), only $VO_2$max(ml/kg/min) and $VO_2$max(%) were low(p<0.01). $FEV_1$(%) was correlated with $VO_2$max(%)(r=0.52;p<0.01), but not predictive of exercise performance. The focal score had the correlation with max WR(%) (r=0.55;p<0.01). Sensitivity and specificity analysis were utilized to compare the different criteria used to evaluate the severity of pulmonary impairment, revealed that the classification would be different according to the criteria used. And focal score for dyspnea showed similar sensitivity and specificity. Conclusion : According to these result, resting PFTs were not superior to rating of dyspnea in prediction of exercise performance in patients with chronic pulmonary diseases and less correlative with focal score for dyspnea than $VO_2$max and max WR. Therefore, if not contraindicated, CPX would be considered to evaluate the severity of pulmonary impairment in patients with chronic pulmonary diseases, including with severe resting PFTs. Current criteria used to evaluate the severity of impairment were insufficient in considering the degree of dyspnea, so new criteria, including the severity of dyspnea, may be necessary.

  • PDF