• Title/Summary/Keyword: Parallel coupled line

Search Result 98, Processing Time 0.038 seconds

Compact Planar Dual-Wideband Bandstop Filters with Cross Coupling and Open-Ended Stepped Impedance Resonators

  • Velidi, Vamsi Krishna;Sanyal, Subrata
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.148-150
    • /
    • 2010
  • This letter presents the design of a compact bandstop filter (BSF) operating at two frequencies. The proposed BSF consists of open-ended stepped impedance resonators (OSIR) and an end-shorted parallel-coupled microstrip line (E-PCML). The OSIRs are used to achieve the impedance-controlled stopband positions. The wide BSF bandwidths are achieved through enhanced coupling of the E-PCML. Explicit design guidelines are derived using a lossless transmission line model. To validate theoretical predictions, a prototype dual-band BSF operating at 900 MHz and 2,100 MHz with fractional bandwidths of 72% and 36%, respectively, is implemented in microstrip.

Droop Control to Compensate Load Voltage Unbalance for Inverter-based Distributed Generations with Unequal Impedance Lines (불균등 임피던스 선로를 갖는 인버터기반 분산전원의 부하전압 불평형을 보상하는 드룹 제어)

  • Yang, Won-Mo;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1193-1203
    • /
    • 2016
  • This paper proposes a droop control scheme to compensate the unbalanced line-to-line voltage of unbalanced 3-phase load which is coupled with two inverter-based distributed generations through unequal impedance lines. Unbalanced line-to-line load voltages occur due to using single-phase loads, which brings about bad effects on the coupled inverters and the distributed generations. In order to compensate the unbalanced line-to-line voltages, a positive sequence voltage control was used for sharing the active and reactive power and a negative sequence control was used for reducing the negative sequence voltage. The feasibility of the proposed scheme was first verified by computer simulations, and then experiments with a hardware set-up built in the lab. The experimental results were compared with the simulation results to confirm the feasibility of the proposed scheme.

A Band Pass Filter with Directly Coupled Feeding Structure Using K-Inverter (K-인버터를 이용한 직접 결합 급전 구조를 갖는 대역 통과 필터)

  • Kim, In-Seon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.639-647
    • /
    • 2007
  • This paper proposed the novel method that can realize the parallel coupled line(PCL) band-pass filter with directly coupled feeding structure by means of transforming the first and last PCL sections of the conventional PCL band-pass filter into K-inverters, then substituting T-type equivalence for K-inverter. The proposed method supplies simple design formulae and can considerably reduce time and efforts needed to optimize filter performance when compared to reported methods using external Q or equivalent parameters. On the basis of the proposed method, the band-pass filter using directly coupled feeding structure and having 18% fractional bandwidth was designed and fabricated. The validity of proposed method was proven by the measured result.

Study on Coupling Characteristics between TE01δ Mode Dielectric Resonator and Coplanar Waveguide Structure (TE01δ 모드 유전체 공진기와 코플래나 웨이브가이드 구조들과의 결합 특성 연구)

  • Kim, Jong-Hyuk;Kim, Ihn S.
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.2
    • /
    • pp.147-155
    • /
    • 2005
  • In this paper, we propose that three uniform coplanar waveguides(CPWs), such as a conventional, finite grounded(FG), and grounded(G) CPWs, can be coupled with a $TE_{01{\delta}}$ mode dielectric resonator(DR) for a parallel resonant characteristic as a microstrip line coupled with the DR. Coupling characteristics have been investigated by placing the DR on a dielectric support above the CPWs and by moving the DR away from the center of a slot of the CPWs to the ground plane. FEM simulation(HFSS) results in terms of S-parameters agree well with measurement results. Finally, unloaded Q values of the DR coupled with the three uniform CPWs are compared with those of the DR coupled with a microstrip line. The comparison shows that the DR coupled with the three CPWs has higher unloaded Qs than that coupled with a microstrip line and that the GCPW case has the highest unloaded Qs.

  • PDF

Hull/Mooring/Riser Coupled Dynamic Analysis of a Turret-Moored FPSO Compared with OTRC Experiment

  • Kim Young-Bok;Kim Moo-Hyun
    • Journal of Ship and Ocean Technology
    • /
    • v.8 no.3
    • /
    • pp.26-39
    • /
    • 2004
  • A vessel/mooring/riser coupled dynamic analysis program in time domain is developed for the global motion simulation of a turret-moored, tanker based FPSO designed for 6000-ft water depth. The vessel global motions and mooring tension are simulated for the non-parallel wind-wave-current 100-year hurricane condition in the Gulf of Mexico. The wind and current forces and moments are estimated from the OCIMF empirical data base for the given loading condition. The numerical results are compared with the OTRC(Offshore Technology Research Center: Model Basin for Offshore Platforms in Texas A&M University) 1:60 model-testing results with truncated mooring system. The system's stiffness and line tension as well as natural periods and damping obtained from the OTRC measurement are checked through numerically simulated static-offset and free-decay tests. The global vessel motion simulations in the hurricane condition were conducted by varying lateral and longitudinal hull drag coefficients, different mooring and riser set up, and wind-exposed areas to better understand the sensitivity of the FPSO responses against empirical parameters. It is particularly stressed that the dynamic mooring tension can be greatly underestimated when truncated mooring system is used.

V-band CPW 3-dB Directional Coupler using Tandem Structure (Tandem구조를 이용한 V-band용 CPW 3-dB 방향성 결합기)

  • Moon Sung-Woon;Han Min;Baek Tae-Jong;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.41-48
    • /
    • 2005
  • We design and fabricate 3-dB tandem directional coupler using the coplanar waveguide structure which is applicable to balanced amplifiers and mixers for 60 GHz wireless local area network system. The coupler comprises the multiple-sectional parallel-coupled lines to facilitate the fabrication process, and enable smaller device size and higher directivity than those of the conventional 3-dB coupler employing the edge-coupled line. In this study, we adopt the structure of two-sectional parallel-coupled lines of which each single-coupled line has a coupling coefficient of -8.34 dB and airbridge structure to monolithically materialize the uniplanar coupler structure instead of using the conventional multilayer or bonded structure. The airbridge structure also supports to minimize the parasitic components and maintain desirable device performance in V-band (50$\~$75 GHz). The measured results from the fabricated couplers show couplings of 3.S$\~$4 dB and phase differences of 87.5$^{\circ}{\pm}1^{\circ}$ in V-band range and show directivities higher than 30 dB at a frequency of 60 GHz.

An Experimental Study on Multiple ICP & Helicon Source for Oxidation in Semiconductor Process

  • Lee, Jin-Won;Na, Byoung-Keun;An, Sang-Hyuk;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.271-271
    • /
    • 2012
  • Many studies have been investigated on high density plasma source (Electron Cyclotron Resonance, Inductively Coupled Plasma, Helicon plasma) for large area source after It is announced that productivity of plasma process depends on plasma density. In this presentation, we will propose the new concept of the multiple source, which consists of a parallel connection of ICP sources and helicon plasma sources. For plasma uniformity, equivalent power (especially, equivalent current in ICP & Helicon) should distribute on each source. We design power feeding line as coaxial transmission line with same length of ground line in each source for equivalent power distribution. And we confirm the equivalent power distribution with simulation and experimental result. Based on basic study, we develop the plasma source for oxidation in semiconductor process. we will discuss the relationship between the processing parameters (With or WithOut magnet, operating pressure, input power ). In ICP, plasma density uniformity is uniform. In ICP with magnet (or Helicon) plasma density is not uniform. As a result, new design (magnet arrangement and gas distributor and etc..) are needed for uniform plasma density in ICP with magnet and Helicon.

  • PDF

Design of Coupling and Rectifying Circuit for Monitoring of Transmitting Power of Maritime VHF Modem (해상 VHF 모뎀의 송신전력 모니터링을 위한 결합기 및 정류회로 설계)

  • Kim, Seung-Geun;Sung, So-Young;Lim, Young-Kon;Park, Dong-Kook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2642-2648
    • /
    • 2010
  • The design of coupling and rectifying circuits for the maritime VHF digital modem is investigated in this paper. To monitor the transmitting power of the modem, a directional coupler which is used to extract a small fraction of the transmitter signal power, and a rectifying circuit which make DC voltage proportional to the coupled rf power are designed and fabricated. The parallel-coupled line coupler with directivity of above 25 dB at 160 MHz bands is designed and it is shown that the output voltage of the rectifying circuit is linearly changing from 0.85 V to 1.6 V when the transmitting power of the modem is varying from 1 W to 25 W. The proposed coupler and rectifying circuits are expected to be suitable for maritime VHF digital modem.

Small Broadband Rectangular Disk-Loaded Monopole Antenna with Electromagnetically Coupled Feed (전자기적 결합 급전 소형 광대역 사각 디스크-로디드 모노폴 안테나)

  • 정종호;박익모
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.7
    • /
    • pp.653-660
    • /
    • 2004
  • This paper presents monopole antenna with electromagnetically coupled feed and its equivalent circuit model. The proposed structure is consists of a rectangular disk-loaded monopole and a probe with rectangular spiral strip line feed. The rectangular disk-loaded monopole is represented by parallel RLC resonant circuit and the probe with rectangular spiral strip line feed is represented by series RLC resonant circuit. Therefore broad bandwidth can be achieved through electromagnetic coupling between these structures that generate two resonances within close frequency range. The antenna with electrical dimensions of only 0.075λ$\sub$0/${\times}$0.075λ$\sub$0/${\times}$0.075λ$\sub$0/ has 16.5 % fractional bandwidth for VSWR$\leq$2 at a center frequency of 2.038GHz.

Stability Improvement of 60 GHz Narrowband Amplifier Using Microstrip Coupled Lines

  • Chang, Woo-Jin;Lim, Jong-Won;Ahn, Ho-Kyun;Ji, Hong-Gu;Kim, Hae-Choen
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.741-748
    • /
    • 2009
  • We present an analysis of microstrip coupled lines (MCLs) used to improve the stability of a 60 GHz narrowband amplifier. The circuit has a 4-stage structure implementing MCLs instead of metal-insulator-metal (MIM) capacitors for the unconditional stability of the amplifier and yield enhancement. The stability parameter, U, is used to compare the stability of MCLs with that of MIM capacitors. Experimental results show that MCLs are more stable than MIM capacitors with the same capacitances as MCLs because the parasitic parallel resistances of MCLs are lower than those of MIM capacitors. Moreover, the bandwidth of an amplifier using MCLs is narrower than one using MIM capacitors because the parasitic series inductances of MCLs are higher than those of MIM capacitors.