• Title/Summary/Keyword: Parallel converter

Search Result 583, Processing Time 0.029 seconds

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

Frequency Controlled Series Resonant Converter System for Power Supply of Communication Station (통신 기지국 전원용 주파수 제어 직렬 공진형 컨버터 시스템)

  • 지준근;임영하
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.323-328
    • /
    • 2003
  • In this paper new control strategy of series resonant converter system for power supply of communication station is suggested. Frequency controlled series resonant converter system is robust to load variations because it is POSR(Parallel Output Series Resonant: POSR) type. And it provides stable output voltage by changing switching frequency to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using ACSL(Advanced Continuous Simulation Langage) and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF

A Study on the Converter Drive by Means of Series and Parallel Connection (콘버어터 직병렬 접속 운전에 관한 연구)

  • Chung, Yon-Tack;Seo, Yong-Soo;Hwang, Lak-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.9
    • /
    • pp.347-354
    • /
    • 1984
  • This paper presents a method of improving the power factor and , the waveform of A.C line currents and the output waveforms of AC to DC fully bridge converter systems which is achieved by connecting CON I.II and CON III.IV in series and parallel. The basic principle of the CON I.II.III.IV's operation is simple and feasibility of thease converter is proved by experiments. CON I and CON III are constructed of natural commutation, CON II and CON IV are constructed of forced commutation. The experimental results show that the power factor and waveform of the source currents and the output waveforms are improved by the method of connecting converter in series and parallel and driving it in I, II, III, IV quadrant.

  • PDF

A Study of the Active Resonance Damper for a DC Distributed Power System with Parallel Pulsed Power Loads (병렬펄스부하를 갖는 직류배전시스템을 위한 능동 공진 댐퍼에 대한 연구)

  • La, Jae-Du;Lee, Byung-Hun;Chang, Han-Sol;Woo, Hyun-Min;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1289-1295
    • /
    • 2012
  • An active resonance damper for a DC Distributed Power System(DPS) with parallel loads is presented. Each pulse power load in a DC DPS comprises both a resistive power load and a step-up converter. The step-up converter behave as constant power load(CPL) when tightly regulated and usually cause a negative impedance instability problem. Furthermore, when an input filter is connected to a large constant power load, the instability of DC bus voltage. In this paper, a bidirectional DC/DC converter with a reduced storage capacitor quantitatively are proposed as a active resonance damper, to mitigate the voltage instability on the bus. The validity of the proposed method was confirmed by simulation and experimental works.

A Characteristic Analysis of the Series-Parallel Resonant type DC/DC Converter for Contactless Power System (비접촉 전원장치에 적용한 직병렬 공진형 DC/DC 컨버터의 특성해석)

  • Hwang, Gye-Ho;Lee, Yeung-Sik;Bang, Deok-Je;Moon, In-Ho;Nam, Seung-Sik;Bae, Young-Ho;Kim, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1425-1427
    • /
    • 2005
  • In this paper, with loosely coupled transformer series-parallel resonant type DC/DC converter is analyzed. To get more efficient operating mode of the series-parallel resonant type DC/DC converter, theoretical analysis using normalized parameters are accepted. The proposed converter must be operated in Pulse Frequency Modulation(PFM) switching pattern for the Zero Voltage Switching(ZVS) operation. According to PFM control method, the output voltage of the proposed circuit can be controlled.

  • PDF

A Study on the Design of Format Converter for Pixel-Parallel Image Processing (픽셀-병렬 영상처리에 있어서 포맷 컨버터 설계에 관한 연구)

  • 김현기;김현호;하기종;최영규;류기환;이천희
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.269-272
    • /
    • 2001
  • In this paper we proposed the format converter design and implementation for real time image processing. This design method is based on realized the large processor-per-pixel array by integrated circuit technology in which this two types of integrated structure is can be classify associative parallel processor and parallel process with DRAM cell. Layout pitch of one-bit-wide logic is identical memory cell pitch to array high density PEs in integrate structure. This format converter design has control path implementation efficiently, and can be utilized the high technology without complicated controller hardware. Sequence of array instruction are generated by host computer before process start, and instructions are saved on unit controller. Host computer is executed the pixel-parallel operation starting at saved instructions after processing start

  • PDF

Parallel operation of VISC system for 3[kw] solar cell (3[kw]급 태양전지 가상구현시스템의 병렬운전)

  • Lee S.Y.;Jeong B.H.;Oh B.W.;Lee B.I.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.957-960
    • /
    • 2003
  • Many solar cell way need to be connected by series or parallel to extract the high power Especially, during parallel operation to reduce circulation current the individual converter has to share and control the load current. Generally, Current Sharing(CS) can be implemented using droop and active current sharing method. In this paper, one 3[KW] PWM converter was replaced as one 3[KW] solar cell array(3 parallels, each parallel has twenty single modules), two 3[KW] solar cell way Is Paralleled to generate 6[KW] power. Also each converter used voltage-current controller and Automatic MSCPM(Master-Slave Current-programming Method) for current sharing(AS).

  • PDF

Control and Design of Input Series-Output Parallel Connected Converter for High Speed Train Power System (고속전철 보조전원 장치용 입력직렬-출력병렬 컨버터의 제어 및 설계)

  • Kim, Jeong-Won;Yu, Jeong-Sik;Jo, Bo-Hyeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.4
    • /
    • pp.282-290
    • /
    • 2000
  • In this paper, the charge control with the input voltage feedback is proposed for the input series-output series-output parallel connected converter configuration for the high speed train power system application. This control scheme accomplishes the output current sharing for the output-parallel connected modules as well as the input voltage sharing for the input series connected modules for all operating conditions including the transients. It also offers the robustness for the input voltage sharing control according to the component value mismatches among the modules. And this configuration enables the usage of MOSFET for a high voltage system allowing a higher switching frequency for lighter system weight and smaller size. The performance of the proposed scheme is verified through the experimental results.

  • PDF

Control of Parallel Connected Three-Phase PWM Converters without Inter-Module Reactors

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.116-122
    • /
    • 2015
  • This paper presents a new current sharing control strategy for parallel-connected, synchronised three-phase DC-AC converters employing space vector pulse width modulation (SVPWM) without current sharing reactors. Unlike conventional control methods, the proposed method breaks the paths of the circulating current by dividing the switching cycle evenly between parallel connected equally rated converters. Accordingly, any inter-module reactors or circulating current control will be redundant, leading to reductions in system costs, size, and control algorithm complexity. Each converter in the new scheme employs a synchronous dq current regulator that uses only local information to attain a desired converter current. A stability analysis of the current controller is included together with a simulation of the converter and load current waveforms. Experimental results from a 2.5kVA test rig are included to verify the proposed control method.

A Study on the Controlling Method of Hunting Inducing Point during Parallel Running of alternator Equipped with converter (컨버터가 내장된 교류발전기 병렬운전중의 헌팅 억제에 관한 연구)

  • 노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.346-351
    • /
    • 1999
  • This paper is a research for removing the hunting which came about during the parallel running of the alternators which four-pole six-phase have the converter with twelve diodes to rectify all the waves. Druing the parallel running the hunting came about under the period of 0.2-0.3{sec} not when it's load was the resistance but the capacity at the rpm band 1575[rpm] 1690[rpm] This hunting in our judgement was not come about from the general hunting causes which have been already known to but the special example. And so we checked that the hunting came about or not as per the changes of the rpm exciting current load current and converter and converter output voltage and the following facts were revealed. -The hunting occured during the constant voltage charging where r. p. m band is from 1575[rpm] to 1690[rpm] - The hunting did not came about during the constant power charging in which there was the large difference between the converter output voltage and the battery voltage. -The hunting did not came about in the low rpm band. We could see from the above facts that the existence of the hunting inducing point at the con-stant voltage charging band was the direct cause of the hunting. After trying every possible means to remove the hunting inducing point we could know that the modification of the synchronous generator is suitable for he purpos in view of the small engine room.

  • PDF