파노라마 X선 사진을 이용한 무치악 환자의 방사선학적 연구 (PANORAMIC RADIOGRAPHY IN THE EXAMINATION OF EDENTULOUS PATIENTS)

  • 문제운;최순철
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.259-269
    • /
    • 1992
  • The author has examined the abnormalities in panoramic radiographs of 668 edentulous patients. The distribution, type, incidence, and location of all abnormalities were analized, and the distances between alveolar crest and anatomical structures were measures. (Maxillary measurements were performed between alveolar crest and lower margin of the maxillary sinus and mandibular measurements between alveolar crest and upper edge of the mental foramen.) The obtained results were as follows: 1. Of the 668 panoramic radiographs examined, 103(15.4%) showed one or more abnormalities. 2. The incidence of abnormalities was decreased by years, which was 22.0% in 1970's and 16.8% in 1980's and 12.1 % in 1990's. 3. The distribution of abnormalities as follows; 43 (40.2%) superficial root fragments, 24(22.4%) impacted teeth, 9(8.4%) imbedded root fragments, 7 (6.5%) cysts, 7(6.5%) fractures, 5(4.7%) foreign bodies, 5(4.7%) abnormal radiolucencies, 4(3.7%) abnormal radiopacities, 2(1.9%) bony defects, 1(0.9%) tumor. 4. In the location of abnormalities, 42 cases (35.3%) were in the maxillary posterior region, 26 cases(21.8%) were in the maxillary anterior region, 20 cases(24.4%) were in the mandibular posterior region and 18 cases(15.1%) were in the mandibular anterior region. 5. In the distance between alveolar crest and maxillary sinus, 109 cases(9.7%) were below 0.5㎜, 757 cases(67.6%) were between 0.5㎜ and 10㎜, 254 cases(22.7%) were above 10㎜. In the distance between alveolar crest and mental foramen, 73 cases (8.8%) were below 0.5㎜, 501 cases (60.7%) were between 0.5㎜ and l0㎜ and 252 cases(30.5%) were above 100㎜.

  • PDF

제3대구치와 하악관과의 위치 관계에서 치과용 Cone beam CT의 유용성 (POSITIONAL RELATIONSHIP OF THE MANDIBULAR CANAL AND IMPACTED THIRD MOLARS BY USING DENTAL CONE BEAM COMPUTED TOMOGRAPHY)

  • 추연규;박영인;김진욱;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.492-498
    • /
    • 2009
  • We sought to evaluate the relationship between the mandibular canal and impacted mandibular third molars by using dental cone beam computed tomograph(CBCT) for third molar surgery. A total of 111 patients(177 teeth) offered the images through CBCT and panoramic radiography for the extraction of the mandibular third molars. In CBCT, the accurate relationship between the third molar and the mandibular canal were evaluated. In panoramic radiographies, we evaluated the impacted level and superimposition sign of the mandibular third molar with the mandibular canal, and also, the radiopacity of the white line in the canal. Data were statistically analyzed and estimated by $X^2$-test. In CBCT finding, high prevalence of contact between the mandibular canal and roots occured in the deep impacted third molars, narrowing mandibular canals, bending mandibular canals and cases where the radiopacity of white line of canals were "absence" on panoramic images. It showed statistical significance (P<0.05). When evaluating the mandibular canal and the roots through the panoramic radiography for third molar extraction, it could be difficult to diagnosis accurately. Thus, it is required to have an accurate diagnostic approach through CBCT that could evaluated the location between mandibular canal and root.

Image quality assessment of pre-processed and post-processed digital panoramic radiographs in paediatric patients with mixed dentition

  • Suryani, Isti Rahayu;Villegas, Natalia Salvo;Shujaat, Sohaib;De Grauwe, Annelore;Azhari, Azhari;Sitam, Suhardjo;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.261-268
    • /
    • 2018
  • Purpose: To determine the impact of an image processing technique on diagnostic accuracy of digital panoramic radiographs for the assessment of anatomical structures in paediatric patients with mixed dentition. Materials and Methods: The study consisted of 50 digital panoramic radiographs of children aged from 6 to 12 years, which were later on processed using a dedicated image processing method. A modified clinical image quality evaluation chart was used to evaluate the diagnostic accuracy of anatomical structures in maxillary and mandibular anterior and maxillary premolar region of processed images. Results: A statistically significant difference was observed between pre and post-processed evaluation of anatomical structures(P<0.05) in the maxillary and mandibular anterior region. The anterior region was found to be more accurate in post-processed images. No significant difference was observed in the maxillary premolar region (P>0.05). The Inter-observer and intra-observer reliability of both pre and post processed images were excellent (>0.82) for anterior region and good (>0.63) for premolar region. Conclusion: The application of image processing technique in digital panoramic radiography can be considered a reliable method for improving the quality of anatomical structures in paediatric patients with mixed dentition.

Orthopos$\textregistered$ 파노라마방사선촬영기의 각종 프로그램에 따른 흡수선량 (The absorbed doses from each exposure program of the Orthopos$\textregistered$ panoramic machine)

  • 최순철;이설미
    • Imaging Science in Dentistry
    • /
    • 제31권4호
    • /
    • pp.215-219
    • /
    • 2001
  • Purpose: The objective of this study was to estimate the radiation absorbed doses in certain critical organs in the head and neck region with 16 imaging programs available on the Orthopos/sup (R)/ panoramic machine. Materials and Methods: A Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses were measured at the thyroid gland, the submandibular gland, the parotid gland, the mouth floor. the maxillary sinus, the brain, the mandibular body, the mandibular ramus. the 2nd cervical spine and the skin over TMJ area. Results : The overall absorbed doses with imaging programs available on the Orthopos/sup (R)/ panoramic machine were much less than that of standard program (program 1) except program 8, 11, and 16. Generally, the absorbed doses to the bone marrow of the mandibular ramus and the parotid gland were high, but the absorbed doses to the bone marrow in the mandibular body, brain, maxillary sinus, and, especially, the thyroid gland were very low. Conclusion : The modified imaging programs available on the Orthopos/sup (R)/ panoramic machine can be effectively used in aspect of radiation protection.

  • PDF

Interobserver agreement on the diagnosis of carotid artery calcifications on panoramic radiographs

  • Yoon, Suk-Ja;Shim, Sung-Kyun;Lee, Jae-Seo;Kang, Byung-Cheol;Lim, Hoi-Jeong;Kim, Min-Seok;Kim, Sun-Hun
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.137-141
    • /
    • 2014
  • Purpose: This study was performed to investigate the interobserver agreement on the detection of carotid artery calcifications on panoramic radiographs. Materials and Methods: This study consisted of panoramic radiographs acquired from 634 male patients of the age of 50 years or older. Having excluded carotids of no diagnostic quality, 1008 carotids from the panoramic radiographs of the patients were interpreted by two oral and maxillofacial radiologists independently for the presence of carotid artery calcifications. Statistical analysis was used to calculate the interobserver agreement. Results: Interobserver agreement was obtained for 932 carotids (92.4%). Inconsistent interpretation of 76 carotids (7.5%) between the two observers was found. Cohen's kappa value was 0.688 (p<0.001). Conclusion: The probability of a match between the two observers was substantially high.

파노라마 방사성사진에서 프랙탈 분석 등을 이용한 골다공증 예측 (Prediction of osteoporosis using fractal analysis et cetera on panoramic radiographs)

  • 김주연;나경수
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.79-82
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate whether panoramic radiographs were useful in predicting osteoporosis. Materials and Methods: 50 postmenoposal women between the age of 41.8 and 78.5 were classified as normal and osteoporosis groups according to the bone mineral density of lumbar vertebrae. Panoramic radiographs were taken. Age, body mass index, remaining mandibular teeth, mandibular cortical thickness and morphology, and fractal dimensions at periapical areas of mandibular first molars were evaluated to differentiate the two groups. Results: The age of osteoporotic group was statistically significantly higher than that of normal group (p<0.05), but not the body mass index or number of remaining mandibular teeth. The mean fractal dimension of osteoporotic group was $1.391{\pm}0.085$, and was significantly lower than that of the normal group, which was $1.523{\pm}0.725$ (p<0.01). Thick mandibular cortical thickness was common in normal group, whereas thin or very thin mandibular cortical thickness was common in osteoporotic group and the difference was significant (p < 0.05). C2 pattern was common in normal group followed by C1, whereas C2 was common in osteoporotic group followed by C3. The difference was statistically significant (p< 0.0 1). Conclusion: Age, mandibular cortical thickness and shape, fractal dimension on panoramic radiographs were useful in predicting osteoporosis.

  • PDF

Radiographic changes of mandibular cortical bone in bisphosphonate drug holiday

  • Lee, Dae-Hoon;Seo, Ja-In;Song, Seung-Il;Lee, Jeong-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권4호
    • /
    • pp.219-224
    • /
    • 2022
  • Objectives: There have been few studies to date on the residual effect of bisphosphonate. This study investigated the radiographic changes of mandibular cortical thickness upon bisphosphonate drug holiday. Materials and Methods: This retrospective study includes 36 patients diagnosed with MRONJ (medication-related osteonecrosis of the jaw) at Ajou University Dental Hospital in 2010-2021. All patients stopped taking bisphosphonate under consultation with the prescribing physicians. Panoramic radiographs were taken at the start of discontinuation (T0), 12 months after (T1), and 18 months after (T2) discontinuation of bisphosphonate, respectively. Mental index and panoramic mandibular index were calculated using Ledgerton's method. Paired t-tests were used to analyze differences over time. Results: The difference in indices (mental index and panoramic mandibular index) between T0 and T1 was not statistically significant (paired t-test, P>0.05). However, the difference in these indices between T1 and T2 was statistically significant (paired t-test, P<0.05). Conclusion: The cortical thickness of the mandible decreased in the late stage (after 18 months) as observed by panoramic radiograph.

Panoramic radiological study to identify locally displaced maxillary canines in Bangladeshi population

  • Alif, Sheikh Mohammad;Haque, Sejuty;Nimmi, Naima;Ashraf, Ali;Khan, Saeed Hossain;Khan, Mahfujul Haq
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.155-159
    • /
    • 2011
  • Purpose : This study was performed to determine the prevalence of maxillary canine impaction on a basis of a single panoramic radiograph in Bangladeshi population. Materials and Methods : A random sample of seven hundred panoramic radiographs was collected from the patient record of a dental clinic. All the selected panoramic radiographs were taken from January 2009 to August 2010 by a single panoramic radiograph machine with the same exposure time (19 seconds) for all radiographs. One hundred and twenty panoramic radiographs were excluded to minimize the selection bias. In a dim lit room, an observer assessed the radiographs on a standard radiographic light box. The position of the impacted maxillary canine was recorded in line with the longitudinal axis of a tooth using the edge of a metal ruler. Data were subsequently put on SPSS 11.5 software and chi-square (${\chi}^2$) tests were applied to find out the association. Results : Among 580 panoramic radiographs it was found that impacted maxillary canines were present in only 7 (1.2%) radiographs. A statistical significant difference was found between the age of the patients and the vertical position of the impacted canines (p=0.000) and between the age of the patients and the horizontal position of the impacted canines (p=0.003). Conclusion : The prevalence was found to be low compared with the present study from the limitation of panoramic image. Further study needs to include three-dimensional imaging modality.

치과방사선 검사에서 두부(brain)의 흡수선량 평가 (Evaluation the absorbed dose in brain of dental radiography)

  • 전운선;한동균
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.343-349
    • /
    • 2011
  • 치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.

Quantitative localization of impacted mesiodens using panoramic and periapical radiographs

  • Choi, Hang-Moon;Han, Jin-Woo;Park, In-Woo;Baik, Jee-Seon;Seo, Hyun-Woo;Lee, Joo-Hyun;Park, Ho-Won
    • Imaging Science in Dentistry
    • /
    • 제41권2호
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate a new technique for localizing impacted mesiodens using its horizontal magnification ratio on panoramic radiographs. Materials and Methods : Location-magnification equation of a panoramic equipment was obtained from horizontal magnification ratio of a metal ball which was located variable positions from the center of image layer at interval of 2 mm. Panoramic radiographs were obtained from a skull phantom with a metal ball which was a substitute for impacted mesiodens and was embedded 10mm(Group 1), 15mm(Group 2), and 20mm(Group 3) posterior to the central incisor. Each group obtained 7 panoramic radiographs at variable positions and one periapical radiograph. Three methods were used to estimate the actual width of the incisors and the balls which were used to calculate the magnification ratio. The methods included using the actual incisor width and the calculated ball width (Method 1), using the actual incisor width and the ball widths measured on periapical radiograph (Method 2), and using the incisor and the ball widths measured on periapical radiograph (Method 3). The location of the metal ball was calculated by using the location-magnification equation. Results : The smallest difference between the calculated and the actual distance was $0.1{\pm}0.7 \;mm$ in Group 1/ Method 3. The largest difference was $-4.2{\pm}1.6 \;mm$ in Group 3/Method 2. In all groups, method 3 was the most accurate. Conclusion : Quantitative localization of impacted mesiodens is possible by using panoramic radiograph.