• Title/Summary/Keyword: Panoramic Radiography

Search Result 292, Processing Time 0.026 seconds

Absorbed Dose in the Full-mouth Periapical Radiography, Panoramic Radiography, and Zonography (전악치근단방사선사진촬영, 파노라마방사선사진촬영 및 협각단층촬영시의 흡수선량)

  • Choi Soon-Chul;Choi Hang-Moon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.255-260
    • /
    • 1999
  • Purpose: The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ. parotid gland. bone marrow in the mandibular body. and thyroid gland during the full-mouth periapical radiography. panoramic radiography. and zonography were measured. Resul ts: From the zonography. the absorbed doses to the brain. the skin over the TMJ. and the parotid gland were relatively high. but the absorbed doses to the bone marrow in the mandibular body and. especially. the thyroid gland were very low. Conclusion: The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  • PDF

Reproducibility of panoramic radiography in patients (임상에서 촬영되는 파노라마 방사선사진의 재현성 조사)

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.115-119
    • /
    • 2005
  • Purpose : To evaluate the magnification error percentage in repeatedly taken panoramic radiographs of same patient and machine. Materials and Methods : 92 panoramic radiographs from 46 patients were traced and 30 horizontal and vertical measurements were made with digital sliding caliper. The results were compared with paired t-test. Results : There was no statistically significant difference between the two measurements. The overall difference as percentage error was $6.19\pm5.60\%$. The largest error as $14.61\pm12.44\%$ was found at condylar height 1, and smallest as $1.86\pm1.61\%$ at mandibular height. Overall vertical error excluding condylar height 1 was $3.76\pm3.97\%$, and the horizontal error $6.88\pm5.92\%$. Conclusion . Repeatedly taken panoramic radiographs of the same patient and machine was reliable since there was no significant percentage error difference but the percentage error ranged from $1.86\pm1.61\%\;to\;14.61\pm12.44\%$ indicating the error depends on the measuring site.

  • PDF

Craniometaphyseal dysplasia: Report of 2 cases with an emphasis on panoramic imaging features

  • Yeom, Han-Gyeol
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.283-287
    • /
    • 2018
  • Craniometaphyseal dysplasia (CMD) is a rare hereditary disorder characterized by hyperostosis of the craniofacial bones and flared metaphyses of the long bones. Although some reports have described the dentomaxillofacial characteristics of CMD, including increased density of the jaw, malocclusion, and delayed eruption of the permanent teeth, only a few studies have reported the distinct imaging features of CMD on panoramic radiography. This report presents 2 cases of confirmed CMD patients with an emphasis on panoramic imaging features. The patients' images revealed hyperostosis and sclerosis of the maxilla and mandibular alveolar bone, but there was no change in the mandibular basal bone. In both cases, the mandibular condyle heads exhibited a short clubbed shape with hyperplasia of the coronoid process. For patients without clear otorhinolaryngological symptoms, common radiologic features of CMD could be visualized by routinely-taken panoramic radiographs, and further medical examinations and treatment can be recommended.

STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong Kyoon
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.182-186
    • /
    • 2014
  • Recently, the use of panoramic radiography has shown a constant increase, and significant research is underway. However, radiation exposure attracts less attention in dental radiography than in other types of radiography. We used an OSLD for measurement of the entrance skin dose in eyeballs and the thyroid region, both of which are not covered by examinations but are included in radiographical regions and are sensitive to radiation, as well as orally in Incheon and reported the results. The entrance skin dose was 0.0282 mSv on average for the oral region, and 0.0259 mSv on average for the eyeball, and 0.0261mSv on average, for thyroid gland. While there is no proper shielding method for the eyeball, a thyroid protector is not used by most hospitals and most hospitals are equipped with an apron and a thyroid protector separately; thus, it is necessary to use an integration of an apron and a thyroid protector and medical device manufacturers need to develop a method for controlling the length of the slit in the slit-type area of radiation occurrence in order to reduce unnecessary exposure.

An atypical case involving real, ghost, and pseudo-ghost images on a panoramic radiograph

  • Jong-Won Kim;Yo-Seob Seo
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • Purpose: This report presents a unique case featuring real, ghost, and pseudo-ghost images on the panoramic radiograph of a patient wearing earrings. It also explains the formation of these images in an easy-to-understand manner. Materials and Methods: One real image and two ghost images appeared on each side of a panoramic radiograph of a patient wearing earrings on both sides. Of the two ghost images on each side, one was considered a typical ghost image and the other was considered a ghost-like real image (pseudo-ghost image). The formation zones of the real, double, and ghost images were examined based on the path and angles of the X-ray beam from the Planmeca ProMax. To simulate the pseudo-ghost and typical ghost images on panoramic radiography, a radiopaque marker was affixed to the right mandibular condyle of a dry mandible, and the position of the mandible was adjusted accordingly. Results: The center of rotation of the Planmeca ProMax extended beyond the jaw area, and the area of double image formation also reached beyond the jaw. The radiopaque-marked mandibular condyle, situated in the outwardly extending area of double image formation, exhibited triple images consisting of real, double (pseudo-ghost), and ghost images. These findings helped to explain the image formation associated with the patient's earrings observed in the panoramic radiograph. Conclusion: Dentists must understand the characteristics and principles of the panoramic equipment they use and apply this understanding to taking and interpreting panoramic radiographs.

Radiographic evaluation of the course and visibility of the mandibular canal

  • Jung, Yun-Hoa;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Purpose: This study was performed to investigate the course of the mandibular canal on panoramic radiography and the visibility of this canal on both panoramic radiography and cone-beam computed tomography (CBCT). Materials and Methods: The study consisted of panoramic radiographs and CBCT images from 262 patients. The course of the mandibular canal, as seen in panoramic radiographs, was classified into four types: linear, elliptical, spoon-shaped, and turning curves. The visibility of this canal from the first to the third molar region was evaluated by visually determining whether the mandibular canal was clearly visible, probably visible, or invisible. The visibihlity of the canal on panoramic radiographs was compared with that on CBCT images. Results: Elliptical curves were most frequently observed along the course of the mandibular canal. The percentage of clearly visible mandibular canals was the highest among the spoon-shaped curves and the lowest among the linear curves. On panoramic radiographs, invisible mandibular canals were found in 22.7% of the examined sites in the first molar region, 11.8% in the second molar region, and 1.3% in the third molar region. On CBCT cross-sectional images, the mandibular canal was invisible in 8.2% of the examined sites in the first molar region, 5.7% in the second molar region, and 0.2% in the third molar region. Conclusion: The visibility of this canal was lower in the first molar region than in the third molar region. The mandibular canal presented better visibility on CBCT images than on panoramic radiographs.

Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

  • Kocasarac, Husniye Demirturk;Celenk, Peruze
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.99-107
    • /
    • 2017
  • Purpose: Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Materials and Methods: Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. Results: The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. Conclusion: The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

Stenosis of calcified carotid artery detected on Panoramic Radiography (파노라마방사선사진에서 석회화가 발견되는 경동맥의 협착 정도)

  • Cho, So-Yang;Oh, Won-Mann;Yoon, Suk-Ja;Yoon, Woong;Lee, Jae-Seo;Palomo, Juan M.;Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.157-161
    • /
    • 2009
  • Purpose : This study aimed to investigate the luminal stenosis of the internal carotid artery with calcification detected on panoramic radiographs. Materials and Methods : This study used fifty carotid arteries of 36 dental patients whose panoramic radiograph and computed tomography angiography (CTA) revealed the presence of carotid artery calcification. A neuroradiologist interpreted CTA to determine the degree of stenosis of the internal carotid arteries. The degree of stenosis was stratified in four stages; normal (no stenosis), mild stenosis (1-49%), moderate stenosis (50-69%) and severe stenosis (70-99%). Results : Among the fifty carotid arteries with calcification detected on both panoramic radiography and CTA, 20 carotid arteries (40%) were normal, 29 carotid arteries (18%) had mild stenosis, 1 carotid artery (2%) had moderate stenosis, and there was none with severe stenosis. Conclusion : Sixty percent of the carotid arteries with calcification detected on both panoramic radiography and CTA had internal luminal stenosis, and two percent had moderate stenosis. When carotid atheroma is detected on panoramic radiograph, it is possible that the dental patient has luminal stenosis of the internal carotid artery.

  • PDF

Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography (파노라마방사선사진에서 구획별 교합면 기준선에 대한 치아근원심경사)

  • Kim Jae-Duk;Kim Jin-Soo;You Choong-Hyun
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.25-31
    • /
    • 2005
  • Purpose : To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Materials and Methods : Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occlusion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. Results : With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. Conclusion : It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  • PDF

EFFECTIVE DOSE FROM CONE BEAM CT FOR IMAGING OF MESIODENS (상악 정중과잉치 진단을 위한 cone beam CT의 유효선량)

  • Han, Won-Jeong;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • Purpose : This study was aimed to calculate effective dose from cone beam CT and compare effective dose from periapical and panoramic radiography for mesiodens. Materials and Methods : Upper anteiror periapical, panoramic radiography and cone-beam CT were taken for diagnosis of mesiodens. The effective dose were calculated by using an anthropomorphic phantom loaded with thermoluminescent dosimeters at the 23 sites related to sensitive organs. Results : The highest absorbed doses were received by the mandibular body, parotid gland and cheek from periapical, panoramic and cone-beam CT, respectively. The effective doses for periapical, panoramic radiography and cone-beam CT measured 2, 18 and 48 ${\mu}Sv$. Conclusion : Cone-beam CT, although providing additional diagnostic benefits, exposes patients to higher levels of radiation than conventional periapical and panoramic radiography.