• Title/Summary/Keyword: Panel Stiffness

Search Result 284, Processing Time 0.027 seconds

Stress Analysis on a Structure of Solar Tracker Subjected to Wind Load (풍하중을 받는 태양광 추적 구조물의 응력해석)

  • Kim, Yong-Woo;Kim, Won-Bong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.747-754
    • /
    • 2012
  • A solar power generator is usually installed outdoors and it is exposed to extreme environments such as snow weight and wind loading. The solar tracker structure should be designed to have sufficient stiffness and strength against such loads. In this paper, simulations are performed by varying the parameters such as wind directions, wind speeds and the pose of the solar panel to evaluate the effects of extreme wind on solar tracker. As the effects of wind load, maximum displacement and maximum equivalent stress in the solar tracker are calculated. Finite element stress analysis is carried out by using the pressure distribution that is obtained by prior wind load analysis due to the flow around the solar tracker. The stress analysis of solar tracker to check and/or improve structural robustness provides some useful instructions for structural design or revision of solar tracker.

Shear performance of green timber wall panels (그린팀버월 패널의 전단성능)

  • Kim, Yun-Hui;Shin, Il-Joong;Jang, Sang-Sik
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.541-547
    • /
    • 2011
  • Korean building industry was developed by concrete and steel construction. However, concrete and steel have some problems which low carbon storage capability and difficulty of recycling. According to many studies, timber has high carbon storage capability, high recycling capability and sustainable supporting capability. Focus on this factors of timber, make new wall structure as Green Timber Wall panels and check the shear performance to use wall system in housing construction such as light-weight timber construction and nondearing wall on other construction. In the results, B-4-B and B-4-S show similar modulus of shear stiffness on the table. GH-4-GH has slip shape failure mode between Green Timber Wall boards. GH-4-GV has most stable characteristic curve than other specimens.

Shear Buckling Behavior for Trapezoidal Corrugated Webs for Bridges (파형강판 복부의 전단좌굴거동 연구)

  • 이필구;윤태양;이학은;이승록
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.513-520
    • /
    • 2003
  • As a trapezoidal corrugated steel plate has the sufficient stiffness out of plane direction without shear stiffener or thick plate, a use in the web of bridge structure is on the increase. However, there are no domestic design guides for shear buckling strength of corrugated plates. Therefore, foreign design specifications are analyzed about application methods and a numerical parametric study is used to get the relationship of the shear strength and geometric boundary conditions for corrugated plates. Elastic buckling finite element analysis is executed through eigenvalue analysis using the eight nodes five freedoms thin shell element. Parameters such as the width and height of panel and the thickness and height of web, are determined considering the factors to influence on the buckling of corrugated plate. Accuracy of shear buckling analysis is evaluated with theory of foreign buckling equations.

  • PDF

Buckling Probability Evaluation Framework of CWR Tracks (장대레일 궤도의 좌굴확률평가 시스템)

  • Bae, Hyun-Ung;Han, Seung-Ryong;Choi, Jin-Yu;Lim, Nam-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.305-309
    • /
    • 2010
  • The buckling behavior of CWR tracks is affected by the various parameters such as stiffness and geometry of track panel, ballast resistance, rail temperature, initial imperfection, and wheel load. Until now, CWR tracks were managed by the dichotomous logic (deterministic approach) despite these influence factors are having the nature of random variables. So, the design method and existing management process to prevent the track buckling can be very non-economic since the value of these influence factors to calculate the track buckling strength are selected by considering the worst track condition. In this study, buckling probability evaluation process is proposed which is based on the reliability index, AFOSM method, and limit state equation.

  • PDF

Investigating of a Floor-Impact Isolation System Using Damping Materials In Apartment Buildings (공동주택에서 완충재를 이용한 바닥충격음 저감 System 연구)

  • 송희수;정영;정정호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.499-504
    • /
    • 2004
  • The purpose of this study is to investigate a investigating of a floor-impact isolation system using damping materials in apartment buildings. The stiffness elastic modulus(k) by puls impact forces were calculated loss factor by Hilbert transforms. It is absolved that natural frequency was moved floor shock-absorbing materials and the impact force was reduced by floor panel. The slab was constructed by damping materials. As towards a result, the system showed inverse A 45dB by heavy weight-impact noise and inverse A 52dB by light-impact noise. High frequencies impact-noise can be reduced by upgrading naturial frequency of vibration and noise in the system.

  • PDF

Analysis of Dynamic Characteristics Change of Middle-Sized Bus by Attachment of Trim Components (트림 부품의 부착에 따른 중형 버스의 동특성 변화 분석)

  • 이상범;임홍재
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.1
    • /
    • pp.88-93
    • /
    • 2004
  • In general, a fundamental structural design consideration for an automobile is the overall dynamic behavior in bending and torsion. Dynamic behavior of the automobile are mainly influenced by the structural stiffness of B.I.W.(body-in-white) and the physical property of trim components. In this paper, the modeling techniques for various trim components of middle-sized bus are presented, and the dynamic effects of the trim components on the vibration characteristics of the bus are investigated. The $1^{st}$ torsional frequency is decreased by attaching windshield and backlite to the B.I.W., but the $1^{st}$ vertical bending frequency and the $1^{st}$ lateral bending frequency are increased. The natural frequencies of the bus are decreased by attaching doors and windows. And also, the natural frequencies of the bus are large decreased by attaching seats, instrument panel etc. The study shows that the dynamic characteristics of the bus can be effectively predicted in the initial design stage.

Dynamic Analysis of the High-Speed Spindle Structure for Machining Center (머시닝센터용 고속주축 구조물의 동특성 해석)

  • 송승훈;권오철;장낙영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.958-968
    • /
    • 1994
  • This paper presents a dynamic analysis of the high-speed spindle system for vertical machining center using finite techniques. The computed natural frequencies are compared with the measured frequencies obtained from experimental modal analysis. The results show that the bending and twisting deformations of the spindle housing dominate in the lowest modes owing to low dynamic stiffness of the housing structure. The design parameters in the analysis are : (a) panel thickness of the housing (b ) height of the housing, and (c) spindle-to-column distance of the housing. Through sensitivity analysis and optimizing simulation considering design constraints, an optimal design of the spindle system has been obtained.

  • PDF

An Analysis of Floor Impact Noise by using Wave Model (Wave 모델을 이용한 바닥충격음 해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1417-1420
    • /
    • 2006
  • In this paper, floor impact is studied by using 1-D wave model and predicted insertion loss is compared to the measurements done in the mock-up. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t or 50t panel is used to construct wall and ceiling inside the steel structure. Various floating floor structures are studied, in which mineral wool thickness, height, and stiffness changes are investigated. It is shown that the wave model and measurements are in good agreements in general, although there occur significant discrepancies in the low frequency range below 200 Hz.

  • PDF

A Case Study on Inside Noise Reduction of Agricultural Tractor Cab(II) -Noise Reduction- (농용 트랙터의 안전캡 내부 소음 감소에 관한 연구(II) -소음 감소 효과-)

  • 유동호;김경욱;최창현
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.127-132
    • /
    • 1995
  • In the first part of this paper, an analysis of the cab noise of a selected agricultural tractor was presented. In this study, using the results of the previous analysis, two passive noise control measures of the sound insulation and absorption were conducted to reduce the noise level inside the cab. These measures of noise control reduced the total noise level by 6.2㏈(A) at the operator position inside the cab. In order to further reduce the cab noise, particularly, of lower frequencies than 630Hz, stiffness and damping of the floor panel should be enforced. It was also suggested that a proper suspension for the cab mounting is necessary to reduce the level of structure-born noises.

  • PDF

Strengthening of deficient RC frames with high strength concrete panels: an experimental study

  • Baran, Mehmet;Susoy, Melih;Tankut, Tugrul
    • Structural Engineering and Mechanics
    • /
    • v.37 no.2
    • /
    • pp.177-196
    • /
    • 2011
  • An economic, structurally effective and practically applicable strengthening technique was developed for reinforced concrete (RC) framed buildings. The idea of the technique is to convert the existing hollow brick infill wall into a load carrying system acting as a cast-in-place RC infill wall by bonding relatively thin high strength precast concrete PC panels to the plastered hollow brick infill. For this purpose, a total of eight one-third scale, one bay, one story frames were tested under reversed-cyclic lateral loads. Test frames were designed and constructed with common deficiencies observed in practice. Four different panel types were used for strengthening. Test results showed that both strength and stiffness of the frames were significantly improved by the introduction of PC panels. Experimental results were compared with the analytical approaches suggested by the authors.