• Title/Summary/Keyword: Panel

Search Result 10,489, Processing Time 0.051 seconds

A Study on the Thermal Performance of Embossing Surface Sandwich Panel

  • Son, Cheol-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2001
  • The purpose of this research is to investigate the thermal performance of embossing surface sandwich panel and flat surface sandwich panel. To do this research, thermal performances in summer season at the six points of embossing surface sandwich panel and flat surface sandwich panel are investigated focusing on the temperature. Three kinds of embossing surface sandwich panel and one kind of flat surface sandwich panel are used for this research. At the same size of sandwich panel, the average temperature differences of flat surface sandwich panel between average temperature at the 0.5 mm below copper plate and average outside air temperature and surface temperature are higher than those of embossing surface sandwich panel. The average heat transfer rate of flat surface sandwich panel in higher than that of embossing surface sandwich panel. More study will be needed about the size of diameter and height of embossing, and materials of embossing surface sandwich panel.

  • PDF

A Study on the Thermal Performance of Embossing Surface Sandwich Panel During the Summer (여름철 엠보싱 샌드위치 패널의 열적 성능에 관한 연구 -평판 샌드위치 패널과 비교를 중심으로-)

  • 손철수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.917-924
    • /
    • 2000
  • The purpose of this research is to investigate the thermal performance of embossing surface sandwich panel and flat surface sandwich panel during the summer. To do this research, thermal performances in summer season at the six points of embossing surface sandwich panel and flat surface sandwich panel are investigated focusing on the temperature. Three kinds of embossing surface sandwich panel and one kind of flat surface sandwich panel are used for this research. At the same size of sandwich panel, the average temperature differences of flat surface sandwich panel between average temperature at the 0.5 mm below copper plate and average outside air temperature and surface temperature are higher than those of embossing surface sandwich panel. The average heat transfer rate of flat surface sandwich panel is higher than that of embossing surface sandwich panel. More study will be needed about the size of diameter and height of embossing, and materials of embossing surface sandwich panel.

  • PDF

Analytical solutions for crack initiation on floor-strata interface during mining

  • Zhao, Chongbin
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.237-255
    • /
    • 2015
  • From the related engineering principles, analytical solutions for horizontal crack initiation and propagation on a coal panel floor-underlying strata interface due to coal panel excavation are derived in this paper. Two important concepts, namely the critical panel width of horizontal crack initiation on the panel floor-underlying strata interface and the critical panel width of vertical fracture (crack) initiation in the panel floor, have been presented. The resulting analytical solution indicates that: (1) the first criterion can be used to express the condition under which horizontal plane cracks (on the panel floor-underlying strata interface or in the panel floor because of delamination) due to the mining induced vertical stress will initiate and propagate; (2) the second criterion can be used to express the condition under which vertical plane cracks (in the panel floor) due to the mining induced horizontal stress will initiate and propagate; (3) this orthogonal set of horizontal and vertical plane cracks, once formed, will provide the necessary weak network for the flow of gas to inrush into the panel. Two characteristic equations are given to quantitatively estimate both the critical panel width of vertical fracture initiation in the panel floor and the critical panel width of horizontal crack initiation on the interface between the panel floor and its underlying strata. The significance of this study is to provide not only some theoretical bases for understanding the fundamental mechanism of a longwall floor gas inrush problem but also a benchmark solution for verifying any numerical methods that are used to deal with this kind of gas inrush problem.

Enhancement of Transmittance Efficiency of TFT-LCD using High Transmittance Polarizer and Dielectric Anisotropy Liquid Crystal

  • Lim, Sung-Hoon;Son, Dong-Yeon;Choi, Kyung-Seob;Choi, Jae-Ho;Lee, Jong-Hwan;Choi, Kwang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.661-663
    • /
    • 2009
  • This paper describes a fabrication method for high transmittance panel using newly designed polarizer and liquid crystal with a high dielectric anisotropy (${\Delta}{\varepsilon}$). To enhance the transmittance of the panel without contrast ratio reduction, new polarizer with high transmittance and high ${\Delta}{\varepsilon}$ liquid crystal were used. The transmittance of the liquid crystal display (LCD) panel employed by a new polarizer was increased by 6% over that of the panel with a conventional polarizer and liquid crystal in LCD industry.

  • PDF

A Study on the Patterns of Panel Attrition in the Korea Welfare Panel Study (한국복지패널 마모패턴 특성 및 패널 이탈 모형 추정 연구)

  • Park, Seung-Hwan
    • Asia-Pacific Journal of Business
    • /
    • v.11 no.4
    • /
    • pp.291-301
    • /
    • 2020
  • Purpose - The purpose of this study was to investigate several household characteristics related to panel attrition, examining how they may have conditioned the panel data in the Korea Welfare Panel Study (KOWEPS). Design/methodology/approach - We studied the cause of the differences in household income between the original panel and the new panel in KOWEPS. Findings - To summarize our findings, whereas it is highly likely that a low-income household or a household without health insurance will remain in the panel, it is highly likely that a high-income household or a household of more than three members will be taken off the panel. Research implications or Originality - The proportion of low-income household tends to decrease over the years, which appears to result from an overall increase in household income. Such changes are reflected in the pattern in which older panels have higher estimates of household income than newer panels.

A Study of Panel Denting (판넬의 덴팅에 관한 연구)

  • Jung, Dong-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.610-615
    • /
    • 2001
  • In the interest of improved automotive fuel economy, one solution is reducing vehicle weight. Achieving significant weight reductions will normally require reducing the panel thickness or using alternative materials such as aluminum alloy sheet. These changes will affect the dent resistance of the panel. In this study, the correlation between panel size, curvature, thickness, material properties and dent resistance is investigated. A parametric approach is adopted, utilizing a "design software" tool incorporating empirical equations to predict denting and panel stiffness for simplified panels. The developed design program can be used to minimize panel thickness or compare different materials, while maintaining adequate panel performance.

  • PDF

Study on Development of air-passing soundproofing panel (통풍형 방음벽 개발에 관한 연구 I)

  • Yoon, Je-Won;Sim, Sang-Deok;Kim, Young-Chan;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.638-643
    • /
    • 2011
  • The aluminum soundproofing panel used to the traffic noise reduction will judge with the material to improve because the CO2 emission is greater than other soundproofing panel such as plastic soundproofing panel. Also, if the air-passing soundproofing panel which can endure the fast wind velocity will be developed, it judged that it can reached to the target of low CO2 traffic technology development using the reduction of material cost and the lower consumption of steel. The objective of this study is to improve the soundproofing panel and to develop the air-passing soundproofing panel for the replacement of aluminum sound proofing panel which is more emit CO2 than other soundproofing panel. And, we tried to develop the reduction technology of CO2 emission through the development of air-passing soundproofing panel. At first, the flow and noise simulation were conducted for the purpose of the calculation of wind pressure on soundproofing wall and noise exposure level on receiver points according to the open ratio of air-passing soundproofing panel. And the 1st and 2nd mockup of air-passing soundproofing panel were made, and the design load test were conducted for these mockup.

  • PDF

A Study on the Building Design Guideline Development Considering Photovoltaic Panel Installation (태양광 패널 설치를 고려한 건축 디자인 지침 개발 연구)

  • Moon, Chang-Ho
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.139-146
    • /
    • 2019
  • The purpose of this study is to propose the building design guideline considering photovoltaic panel installation through the analysis of relevant guidelines from home and abroad in terms of building design and solar panel installation. Conclusions can be summarized as followings; Considerations in building design : selection of the site with high solar accessibility, avoidance of the shade from the adjacent building & trees, south facing orientation of solar panel in building design, removal of shade on the solar panel from the part of building itself, load consideration of solar panel & fixing materials, safe passage securement for solar system maintenance, and planning of piping and mechanical room for solar system. Considerations in solar panel installation : harmonizing of solar panel with surrounding environment, unity of solar panel orientation & slope, regular maintenance of solar system, (in case of flat roof installation) solar panel installation afloat over the roof, installation area within the roof floor, and lower than parapet height, (in case of sloped roof installation) solar panel installation parallel with the roof slope, ventilation space securement below the panel, installation area within the roof surface, and similar material installation in empty space.

Relationship of Ceramic Insulation Panel System Development and Verification of LCC

  • Han, Min-Cheol;Jeon, Kyu-Nam;Lee, Gun-Cheol;Kim, Tae-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.386-392
    • /
    • 2012
  • In this study, life cycle cost (LCC) is analyzed according to insulation panel system type using a deterministic LCC analysis method. Through this analysis, it was found that the construction cost in the deterministic LCC analysis for Ceramic panels was low compared to the construction cost for metal and stone panels. Also, the difference in cost between the Ceramic panel and the metal panel was about 2 times. In the area of maintenance cost, it was found to be similar to the previously analyzed construction cost, in which the metal panel has the highest cost due to the high cost of construction and the frequent need for maintenance. In the case of the stone panel, a small difference in cost is shown compared with that of the Ceramic panel, but the cost is higher than the Ceramic panel. Regarding the cost of waste disposal, the Ceramic panel can reduce the cost by at least 1.5 times and up to 2 times compared to other panel systems. Finally, in the analysis of sensitivity according to changes in discount rates, the Ceramic panel and metal panel systems have a similar cost, and the cost of the metal panel is a bit larger than that of other panel systems. Thus, in the subjects used in the analysis, the Ceramic panel system shows the highest economic benefits.

Study on a Forward Light Changes According to the Surface Treatment of Light Cutoff Panel (차광판 표면 처리 방법에 따른 전사광 변화에 관한 연구)

  • Gu, Jinhoi;Kwon, Myunghee;Lee, Yoon-Gyeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.1-5
    • /
    • 2014
  • Since the "Light Pollution Prevention Act" was executed, the installation of the light cutoff panel to the security lightings which caused light trespass has been increased in the local government. The light cutoff panel is effective in reducing the light trespass in term of the cost-benefit. Because the installation of the light cutoff panel is inexpensive than the change of the security lighting. But the reflected light from the surface of the light cutoff panel has been regarded as another light pollution problem to solve. Therefore, we try to improve light cutoff panel by changing the light reflectivity characteristic of the surface of the light cutoff panel. First, we laminated the surface of light cutoff panel by black powder to reduce the light reflectivity of the light cutoff panel. After the black powder lamination, the light reflectivity on the light cutoff panel improved from 85% to 5%. And we compared reflected light caused by black powder laminated light cutoff panel with the one of no surface treatment cutoff panel. The vertical illuminance was measured at 3, 6, 9m in front of the security lighting and 3, 6, 9, 12, 15, 18m in back of the security lighting to evaluate the reflected light. And the measurement height was determined of 1.5m considering the height of the 1th floor of an apartment house. In this study, we found that the reflected light from the light cutoff panel can be reduced about 90% by the black powder lamination method. The results derived from this study will be helpful to develope the various kind of light cutoff panel which minimize the adverse effect like reflected light of light cutoff panel.