• Title/Summary/Keyword: Pain scale

Search Result 3,313, Processing Time 0.027 seconds

Radiographic Changes of the Medial Epicondyle in Little League Baseball Player (청소년기 야구선수의 주관절 내상과의 방사선학적 변화)

  • Choi Chang-Hyuk;Eum Dong-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.43-48
    • /
    • 2002
  • Purpose : We evaluated radiographic changes and clinical manifestations of the elbow joint to identify the effects of the throwing between dominant and non-dominant arms. Materials and Methods : A hundred and five little leaguer’s baseball player in 5 elementary school and 2 middle school were evaluated for clinical symptoms and radiographic changes about elbow joint. Mean age was 12 years old and average periods of exercise were 32 months. Elbow functions were evaluated using ASES standardized assessment form and radiographic changes of medial epicondyle were examinated for enlargement, separation of the apophyses, fragmentation and irregularity. Results : Thirty seven players (35$\%$) were complained pain with throwing and the average score was 4.8 using visual analog scale. There were no significant differences in range of motion except flexion angle, valgus angle, and strength between dominant arm and non-dominant arm. Valgus laxity was more prominent in dominant arm. Ulnohumeral tenderness, radiocapitellar tenderness and medial flexor origin tenderness were in 18, 6, and 17 cases respectively in dominant arm. Medial epicondyle was enlarged in dominant arm with 13.0 by 6.3 mm compared to non-dominant arm with 11.7 by 6.1 mm. Apophyseal separation was 0.8 mm in dominant arm and 0.5 mm in non-dominant arm. Fragmentation and irregularity were 14 (13$\%$) and 25 (24$\%$) cases respectively in dominant arm. Conclusion : In little league baseball player, it needs usage of ball and bat with appropriate weight, and careful conditioning programs through throwing exercise in order to avoid elbow injuries.

  • PDF

A study for diagnosis and pattern identification of Hwa-Byung (화병의 진단 및 변증유형에 관한 연구)

  • Lee, Hui-Young;Park, Jong-Hoon;Whang, Wei-Wan;Kim, Jong-Woo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.1
    • /
    • pp.1-17
    • /
    • 2005
  • Objective : This empirical research is performed to recognize diagnostic concept, pattern identification, and clinical features of Hwa-byung. In other words, the aims of this research are to examine the differences of the diagnosis between Hwa-Byung and the other psychiatric disorders, and to find out pattern identification, and clinical characteristics of Hwa-Byung for prescriptions of this syndrome. Method : In the experiment, there were participated 30 patients who were met for our criterions according to HBDIS (Hwa-Byung Diagnostic interview Schedule). These patients were diagnosed as Axis1 according to criterions of DSM-IV with administering SCID-I. OMS-prime was utilized for finding out pattern identification of oriental medicine. Symptom Check List-90-Revision(SCL-90-R), Hemilton rating Scale for Depression(HRSD), Heart Rate Variability(HRV), and Digital Infrared Thermographic imaging(D.I.T.I.) were also utilized to discover clinical characteristics of Hwa-Byung Patients. Results : 1. Regarding Sex-ratio, male subjects were 3(10%), and female subjects are 27(90%). The age of subjects ranged from 22 year old to 75 $(51.87{\pm}11.04;\:Mean{\pm}SD)$ 2. In the results of diagnosis on the basis of DSM-IV, the 17(56.67%) patients were MOD (Major Depressive Disorder), the 5(16.67%) patients were USD (Undifferentiated Somatoform Disorder), the 4(13.33%) patients were Dysthymic Disorder, the 3(10%) patients were GAD (Generalized Anxiety Disorder), and the 1(3.33%) was Panic Disorder. Two of the patients who diagnosed as MOD were diagnosed as Panic Disorder too, and one of them was diagnosed as Pain Disorder too. 3. Regarding pattern identification, Hwa-Byung is positively correlated to deficiency of Heart(心). and then to stagnancy of Liver-Gall bladder. Hwa-Byung is correlated deficiency symptom-complex rather than excessiveness symptom-complex. That is also correlated positively to Pathological heat and fire. 4. In SCL90-R, the mean of PSDI was $(75.3{\pm}10.7;\:Mean{\pm}SD)$. The each mean of the other 11 factors was distributed between50-70. 5. The mean of HRSD was $(17.9{\pm}5.6;\:Mean{\pm}SD)$ in the entire subject's group. Then the group of MDD was $20.9{\pm}4.4$ and the group of USD was $12.0{\pm}4.8$ 6. In the results of HRV. the mean of TP is $972.4{\pm}1174(Mean{\pm}SD)$, this is lower than normal range 1000-200. The other factors were within normal range. Then, there were no significant differences between them (p<0.05). 7. The temperatures of each acupoint have significant differences between HNl(印堂) and PC6(內關), between CV17(顫中) and PC6(內關), between HN1(印堂) and CV8(神闕), between CV17(顫中) and CV8(神闕) in comparison with the average of body temperature in the use of D.I.T.I. (p<0.01) 8. In the analysis of correlation between SCL-90-R, HRSD, HRV. and D.I.T.I. there were no significant results. According to results that the correlation was analyzed with only the MDD group as subjects, there was negative correlation between RMSSD of HRV and HRSD, between LF of HRV and PDSIof SCL-90-R, and between LF/HF of HRV and ANX, PSY, and PDSI of SCL-90-R. Conclusion : In the observation of clinical features of 30 cases of Hwa-Byung patients by using diverse structured tests, there could make diverse diagnosis as depressive disorder, anxiety disorder, and Somatoform Disorder. Particularly. MDD was highly distributed. Considering oriental medicine's pattern identification of Hwa-Byung, this syndrome is related strongly to Heart, and there were demonstrated deficiency symptom-complex, and Pathological heat and fire. One of the limits of this study is lack of control subject's group, therefore, in the future study, it requires reexamination through a comparative research with these data to complete this study.

  • PDF

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.