• Title/Summary/Keyword: Pad Pressure

Search Result 330, Processing Time 0.034 seconds

Robust Control of Synchronous Vibration of a Rotor System with PZT Actuator (PZT 액추에이터를 이용한 로터계 동기진동의 강인제어)

  • Gwon, Dae-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.711-719
    • /
    • 2002
  • This paper presents the synchronous vibration control of a rotor system using an active air bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by pivots containing piezoelectric actuators and their radial position can be actively controlled by applying voltage to the actuators. Thus, disturbances, i. e. various kinds of external force can cause shaft vibration as well as change of the air film thickness. The dynamic behavior of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The $\mu$ synthesis are applied to the AAB system with three pads, two of which contain piezoelectric actuators. To test the validity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results also show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

Forefoot disorders and conservative treatment

  • Park, Chul Hyun;Chang, Min Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.92-98
    • /
    • 2019
  • Forefoot disorders are often seen in clinical practice. Forefoot deformity and pain can deteriorate gait function and decrease quality of life. This review presents common forefoot disorders and conservative treatment using an insole or orthosis. Metatarsalgia is a painful foot condition affecting the metatarsal (MT) region of the foot. A MT pad, MT bar, or forefoot cushion can be used to alleviate MT pain. Hallux valgus is a deformity characterized by medial deviation of the first MT and lateral deviation of the hallux. A toe spreader, valgus splint, and bunion shield are commonly applied to patients with hallux valgus. Hallux limitus and hallux rigidus refer to painful limitations of dorsiflexion of the first metatarsophalangeal joint. A kinetic wedge foot orthosis or rocker sole can help relieve symptoms from hallux limitus or rigidus. Hammer, claw, and mallet toes are sagittal plane deformities of the lesser toes. Toe sleeve or padding can be applied over high-pressure areas in the proximal or distal interphalangeal joints or under the MT heads. An MT off-loading insole can also be used to alleviate symptoms following lesser toe deformities. Morton's neuroma is a benign neuroma of an intermetatarsal plantar nerve that leads to a painful condition affecting the MT area. The MT bar, the plantar pad, or a more cushioned insole would be useful. In addition, patients with any of the above various forefoot disorders should avoid tight-fitting or high-heeled shoes. Applying an insole or orthosis and wearing proper shoes can be beneficial for managing forefoot disorders.

Treatment of Third Degree Burn due to Low-Temperature Contact Burn on Acquired Immune Deficiency Syndrome (AIDS) Patient: Low-Temperature Burn on AIDS Patient (후천성면역결핍증후군 환자에서의 저온 접촉 화상에 의한 삼도 화상의 치료)

  • Hong, Seok Won;Choi, Hwan Jun;Kim, Jun Hyuk;Lee, Da Woon
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.21-24
    • /
    • 2019
  • Incidence of low-temperature contact burn by use of an electric pad is increased recently, especially in depressed sensory. Acquired immune deficiency syndrome patient using antiretroviral agent suffered with sensory depression as side effect. There are many limitations in wounds treatment of these patients. These patients are vulnerable to infection due to their weak immunity, so it is necessary to keep them in a state of isolation when a wound occurs. We report a case of a third degree burn by electric pad with a surface area of approximately 5% of the body surface of a patient who underwent a sensory depression, which is a side effect of antiretroviral drugs used for treatment in patients with AIDS. In this regard, we report the case with literature review, which is safely recovered using negative-pressure wound therapy and split-thickness skin graft.

Analytical Model Development of Longitudinal Railway Vehicle (철도차량의 종방향 통합해석모델 검토 및 개발)

  • Kwak Jae-Ho;Choi Kyung-Jin;Shin Yu-Jeong
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.383-386
    • /
    • 2005
  • An integrated analytical model which should have essential dynamics on the longitudinal railway vehicle is developed. The model consists of translational movement, rotational movement, brake actuator, adhesion force between rail and wheel, and brake friction force between wheel and pad. Thus, during the deceleration for stopping, a feedback controller controlling the brake cylinder pressure is designed to improve ride quality and to release friction problems. Through the developed model, the feasibility of controlling the cylinder pressure is verified for the better performances during braking.

  • PDF

A Study on Thermal Behavior Characteristics of Multi-flight Screw in Injection Molding Machine by FEM (유한요소법을 이용한 다중날 사출기 스크류의 열거동 특성 연구)

  • Cho, Seung-Hyun;Lee, Young-Suk;Kim, Sung-Won;Kim, Chung-Kyun
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.285-290
    • /
    • 2002
  • Screw in injection molding machine is affected by heat flux, pressure on inside barrel, geometry of screw including flight number, pitch and flight angle. Volumetric efficiency increases as the flight number increases, but it didn't show steady tendency according to helix angle of flight. Heat flux from heating pad and injection pressure play a very important role on the thermal behavior characteristics. The increased number of multi-flight is merits and demerits for a screw efficiency. So, we have to optimize flight number of the screw considering temperature, displacement, distortion and stress of the screw.

  • PDF

On Application of Optimization Scheme To Direct Numerical Analysis Of Slider

  • Hwang, Pyung;Khan, Polina;Pan, Galina
    • KSTLE International Journal
    • /
    • v.5 no.1
    • /
    • pp.23-27
    • /
    • 2004
  • The object of the present work is the numerical analysis of the computer hard disk slider. The pressure between slider and disk surfaces is calculated using the Boundary Fitted Coordinate System and Divergence Formulation for the nonlinear Reynolds' equation solution. The optimization scheme is applied to search for the steady state position of the slider. The simplified method is given for the case of the fixed inclined pad. The film thickness ratios and pitching and rolling angles are considered as alternative choice of the slider's coordinates. The behavior of the objective function for the Negative Pressure slider is studied in details. Methods of conjugate directions and feasible directions are applied.

The Origin and Effect of Hot Spot Phenomena on Judder Vibration in Automotive Disk Brake (디스크 브레이크에서 열섬 현상이 발생되는 원인과 저더 진동에 미치는 영향)

  • Cho, Ho-Joon;Cho, Chong-Du;Kim, Myoung-Gu;Maeng, Ju-Won;Lee, Jae-Han
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.213-218
    • /
    • 2006
  • Hot spot phenomenon is caused by non-uniform contact area between brake pad and disk frequent braking. Brake disk deformed by locally concentrated heat increases magnitude of frictional vibration. And this deformation can highly influence the judder vibration. In this experimental study, vibration and hot spot was measured in accordance with rotation of disk and pressure of master cylinder for finding the factors that causes hot spot phenomena. For comparing hot spot aspects with mode shapes of disk, mode shapes were measured by conducting modal test, and analyzed by using finite element analysis. Relation between hot spot phenomenon, and mode shape, pressure of master cylinder and rotation speed of disk respectively, was achieved by hot spot measurement and frequency analysis.

  • PDF

The Invention of New Electro-Mechanical Brake Calipers Utilizing Patent Analysis Results (특허분석 결과를 활용한 새로운 전기기계 브레이크의 발명)

  • Han, In-Hwan;Park, Sang-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.125-132
    • /
    • 2007
  • Within the framework of brake-by-wire technology, this paper presents five types of novel models of electro-mechanical disk brake calipers with self-servo mechanism which provides self-servo effect of boosting a friction force generated between the brake pad and the rotor disk surface. The models have been developed utilizing patent map analysis results of previous invents of electro-mechanical brake calipers. The feasibility of the developed motor-driven brake caliper models have been validated through the dynamic simulation analysis. Among the developed models, the caliper mechanism with separated pressure plate was designed especially in detail and was made as a pilot. The pilot caliper has been installed on the simple test bed constructed with domestic passenger car brake components, and its function and effectiveness have been validated through several types of experimental tests.

The Origin and Effect of Hot Spot Phenomena on Judder Vibration in Automotive Disk Brake (디스코 브레이크에서 열섬 현상이 발생되는 원인과 저더진동에 미치는 영향)

  • Cho, Chong-Du;Kim, Myoung-Gu;Cho, Ho-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.886-892
    • /
    • 2006
  • Hot spot phenomenon is caused by non-uniform contact area between brake pad and disk frequent braking. Brake disk deformed by locally concentrated heat increases magnitude of frictional vibration. And this deformation can highly influence the judder vibration. In this experimental study, vibration and hot spot was measured in accordance with rotation of disk and pressure of master cylinder for finding the factors that causes hot spot phenomena. For comparing hot spot aspects with mode shapes of disk, mode shapes were measured by conducting modal test, and analyzed by using finite element analysis. Relation between hot spot phenomenon, and mode shape, pressure of master cylinder and rotation speed of disk respectively, was achieved by hot spot measurement and frequency analysis.

Implementation of the Potable Blood Pressure Measurement System Using Wireless Communication Technology and MAA Algorithm (무선통신기술과 MAA 알고리즘을 이용한 휴대형 혈압측정 시스템 구현)

  • Kim, Bo-Sung;Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.678-681
    • /
    • 2007
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed. The system were composed of pressure control, signal measurement, blood pressure signal processing units and wireless sensor network parts. For verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF