• Title/Summary/Keyword: Packing efficiency

Search Result 204, Processing Time 0.024 seconds

Energy-aware Virtual Resource Mapping Algorithm in Wireless Data Center

  • Luo, Juan;Fu, Shan;Wu, Di
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.3
    • /
    • pp.819-837
    • /
    • 2014
  • Data centers, which implement cloud service, have been faced up with quick growth of energy consumption and low efficiency of energy. 60GHz wireless communication technology, as a new option to data centers, can provide feasible approach to alleviate the problems. Aiming at energy optimization in 60GHz wireless data centers (WDCs), we investigate virtualization technology to assign virtual resources to minimum number of servers, and turn off other servers or adjust them to the state of low power. By comprehensive analysis of wireless data centers, we model virtual network and physical network in WDCs firstly, and propose Virtual Resource Mapping Packing Algorithm (VRMPA) to solve energy management problems. According to VRMPA, we adopt packing algorithm and sort physical resource only once, which improves efficiency of virtual resource allocation. Simulation results show that, under the condition of guaranteeing network load, VPMPA algorithm can achieve better virtual request acceptance rate and higher utilization rate of energy consumption.

A New Evaluation Method for the Effectiveness of Standardized Packing Module (포장모듈 표준화 효과의 평가 방법 연구)

  • Choi, Chang-Ho;Kim, Gwang-Ho;Park, Dong-Joo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.562-568
    • /
    • 2008
  • The modern logistics has tried not only to convert the conventional packing system into unit load system using pallet but also to enhance the fitness between packing facilities and transport modes. This is based on the goal to reduce total logistics cost by improving logistics efficiency. Since the packing unit can affect both loading rate and loading facilities, basic form of packing unit is very important to unit load system. The object of this study is to develop a new method for evaluating the effectiveness of standardized packing module. The new method is based on measure of effectiveness (MOE) which are identified by expert survey. This study has originality in that the collecting method for effectiveness of standardized packing module has not been developed up to now.

Development of Flexible Packing Ring in Steam Turbine for Reduction of Leakage by using CFD Flow Analysis (CFD 유동해석을 이용한 누설 저감을 위한 증기터빈용 플렉시블 패킹링 개발)

  • Kim, Jin Hyung;Bae, Jun Ho;Lee, Chang-Ryeol;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.7
    • /
    • pp.741-748
    • /
    • 2013
  • A conventional packing ring was designed with a large clearance to prevent damage due to the vibration of the rotor, which can lead to an increase in steam leakage. In this study, a flexible packing ring using winding springs was developed to prevent damage to the rotor teeth by minimizing vibration, while maintaining a smaller clearance than that of conventional rotor designs. Theoretical analysis and finite element analysis (FEA) were used to design the winding spring to satisfy the specified allowable stress limit and minimum load requirements. The shape of the winding spring was designed by applying curves to the center and end parts of a flat spring. Computational fluid dynamics (CFD) analysis was used to predict the leakage of the flexible packing ring. Flow rate measurement tests were performed to verify the leakage reduction efficiency and the reliability of the CFD analysis.

Removal Nitrogen and Phosphorus from Wastewater using Natural Zeolite and Iron Oxide (천연 Zeolite와 산화철을 이용한 폐수 중 질소 및 인의 처리)

  • Weon, Seung-Yeon;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.104-109
    • /
    • 2004
  • Removal of nutrients from domestic sewage or industrial wastewater is needed to protect surface waters from eutrophication. This research was carried out to remove the nitrogen (N) and phosphorus (P) from the wastewater using the iron oxide obtained from the steel industry and the natural zeolite, respectively. This research was conducted in both batch and continuous systems. The removal efficiency of the nutrients was evaluated in the batch system using the varying concentrations of zeolite and iron oxide added. The removal efficiency of N was 60% at the 8g of zeolite added. In the same condition, the removal efficiencies of N were 76% and 82% at 12g and 16g of zeolite added, respectively. Removal efficiency of P was 80% as 8g of iron oxide was added. The removal efficiency of P was correspondingly increased as the concentration of iron oxide was increased. Continuous column system was also used to evaluate the removal efficiency of N and P by the addition of zeolite and ferric oxide, respectively. Removal efficiencies of N were compared in the mixed packing, two stage, and four stage columns, respectively. The removal efficiencies (80%) of N in the separate packed columns (two and four stages) were higher than the mixed packing column (400%) after 90 hr. Whereas, the removal efficiencies of P were similar to each other in the three columns.

Preservation of Coagulation Efficiency of Moringa oleifera, a Natural Coagulant

  • Katayon, S.;Ng, S.C.;Johari, M.M.N.Megat;Ghani, L.A.Abdul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.489-495
    • /
    • 2006
  • In recent years, there has been an interest to use Moringa oleifera as the natural coagulant due to cost, associated health and environmental concerns of synthetic organic polymers and inorganic chemicals. However, it is known that M. oleifera as the natural coagulant is highly biodegradable and has a very short shelf life. This research was carried out to investigate the effects of storage temperature, packaging methods, and freeze-drying on the preservation of M. oleifera seeds powders. Non freeze-dried M. oleifera was prepared into different packaging namely open container, closed container and vacuum packing, whilst, freeze-dried M. oleifera was stored in closed container and vacuum packing. Each of the packaging was stored at room temperature ($30\;to\;32^{\circ}C$) and refrigerator ($4^{\circ}C$). The turbidity removal efficiencies of stored M. oleifera were examined using jar test at monthly interval for 12 months. The results indicated that non freeze-dried M. oleifera kept in the refrigerator ($4^{\circ}C$) would preserve its coagulation efficiency. In addition, closed container and vacuum packing were found to be more appropriate for the preservation of non freeze-dried M. oleifera, compared to open container. Freeze-dried M. oleifera retained its high coagulation efficiency regardless the storage temperature and packaging method for up to 11 months. Besides, higher increment in zeta potential values for water coagulated with freeze-dried M. oleifera indicated the higher frequency of charge neutralization and better coagulation efficiency of freeze-dried M. oleifera, compared to non freeze-dried seeds. As a coagulant, M. oleifera did not affect the pH of the water after treatment.

Removal of NH(sub)3-N by Using Immobilized Nitrifier Consortium in PVA[Polyvinyl Alcohol]-I. Effect of Packing Fraction and Aeration Rate on Ammonia Nitrogen Removal (PVA에 고정화된 질화세균군에 의한 암모니아성 질소 제거 I. 충진율 및 공기 유입량이 암모니아성 질소제거에 미치는 영향)

  • 서근학;김병진;오창섭
    • KSBB Journal
    • /
    • v.16 no.3
    • /
    • pp.314-319
    • /
    • 2001
  • A nitrifier consortium immobilized in polyvinyl alcohol was used to remove ammonia nitrogen from synthetic wastewater in an airlift bioreactor. The minimum aeration rates were 0.4, 0.6, 0.8 and 1.0 vvm for 5, 10, 15 and 20% immobilized bead packing volume fraction, respectively. The efficient packing fraction and the aeration rate for ammonia nitrogen removal were 15% and 2.4 vvm, respectively. With a hydraulic retention time of 0.5hr, the removal rate and the efficiency of ammonia nitrogen removal were 1685 g/㎥$.$day and 48% at an influent ammonia nitrogen concentration of 75 g/㎥.

  • PDF

Influence of Orgnainc Pigment Addition on Surface Properties of Coating Layer (유기안료의 첨가가 도공층의 표면특성에 미치는 영향)

  • 정경모;이용규
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.2
    • /
    • pp.47-53
    • /
    • 2004
  • In this experiment the effects of the packing structure of pigment on the surface characteristics (smoothness and gloss) of coated paper are studied. Four different kinds of inorganic pigments(clay), ground calcium carbonate(GCC), two of precipitated calcium carbonates(PCC), and two organic pigments(solid bead and hollow type) were used. The method of measuring the relative sediment volume(RSV) was used to analyze the packing structure of coating layer. The relative sediment volume was measured, using the pressure dewatering dry-cake method(PDDM) and centrifuge method. Also, the particle size distribution of coating pigment was determined. The results showed that small amount of organic pigment, added to inorganic pigment, improved smoothness and its effect was greater when GCC was used as inorganic pigment. The efficiency of organic pigment depended upon the inorganic pigment since the organic pigment is packed in the pores formed by the inorganic pigment.

The effect of HRT, current density, and packing ratio on nitrate nitrogen removal efficiency and current efficiency in BRM-BER (고정상 담체를 충진한 BER에서 HRT, 전류밀도 및 담체 충진율 변화가 질산성 질소 제거효율과 전류이용효율에 미치는 영향)

  • Whang, Gye-Dae;Lee, Sang-Keun;Sung, Hae-Chang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.433-442
    • /
    • 2010
  • BER at different packing ratios of bio-ring media(BRM) was tested to investigate the effect of varying hydraulic retention time (HRT) and current density on the nitrate removal and current efficiency. In the preliminary batch mode experiment of BERs, current density was applied at 2.0 A/$m^2$, 4.0 A/$m^2$, 4.8 A/$m^2$, which correspond to the designation of reactor #1, #2, #3, respectively. The reactor #2 showed a highest nitrate removal rate of 162.0 mg $NO_3{^-}$-N/L/d, and the kinetics of nitrate removal rate was defined as the Zero order reaction. In the primary experiment of BERs, four BERs packed with BRM were operated in varying HRT and current, and the packing ratios of reactor #1, #2, #3 and #4 were 0%, 8%, 16%, 24%. respectively. This results of the experiments indicated that the nitrate removal rate and current efficiency were increased significantly cause of growing of autotrophic denitrification microorganisms on the surface of cathode and media by increasing of the current density and decreasing of HRT. However, The decreasing of nitrate removal rate and current efficiencies were observed in the condition of HRT of 5.25 hr and 4.8 A/$m^2$ of current density. With more increasing current density and decreasing of HRT, the hydrogen inhibition occurred at the surface of cathode. Moreover, nitrate removal rate by autotrophic denitrification microorganisms attached on the media surface was observed to be limited by no longer increasing dissolved hydrogen concentration of each reactor. In conclusion, the highest nitrate nitrogen removal and current efficiency could be achieved when the BER was operated at the conditions of 7 hr HRT, current density of 4.0 A/$m^2$, and 16% packing ratio. And it was found that the amount of nitrate removal by microorganisms attached on the surface of cathode and media (BRM) was 178.2 mg/L and 52.2 mg/L respectively. and the amount of nitrate removal per MLVSS was 0.435 g $NO_3{^-}$-N/g $MLVSS{\cdot}d$ and 0.336 $NO_3{^-}$-N/g $MLVSS{\cdot}d$.

Valve Tray for Large Volume Gas Treatment (대용량의 가스상물질 처리를 위한 밸브트레이)

  • 김재홍;김장호
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.61-65
    • /
    • 2001
  • To review mass transfer trays from a process of view, the dependence of efficiency in loading ranges and maximum loadings with an acceptable efficiency of traditional tray have to be known. It is reported about the performance of the metallic Dualflex, relatively new high performance packing. Absorption, desorption and rectification tests as well as pressure drop and maximum capacity are concerned, indicate the superiority of the Dualflex over the general packing of comparable, main process. The process engineering characteristics show that Dualflex can be applied for all mass transfer precesses and it is to be recommended especially for those high capacity separations which requite allow low pressure drop because of the thermal sensibility of the product or because of the need of energy saving.

  • PDF

A Study on the Effect of an HRT of Anoxic Reactors on Organic Matter and Nitrogen Removal in A2/O Processes with Bio Contact Media in Aerobic Tank (호기조에 고정상 담체를 충진한 A2/O공정에서 무산소조 체류시간 변화가 유기물질 및 질소 제거에 미치는 영향)

  • Whang, Gye-Dae;Han, Bong-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.451-457
    • /
    • 2007
  • Four parallel $A^2/O$ systems maintaining an MLSS of 3,000 mg/L were operated to investigate the effects of varying an HRT of anoxic reactors and packing Bio contact media (BCM, fixed beds) in aerobic reactors on organic matter removal and nitrification/denitrification efficiencies. All systems were operated under conditions that the external recycle ratio was kept 0.5 Q while the internal recycle ratio was changed 1.0 Q to 1.5 Q with that $NH_4-N$ concentration of feed was increased to 40 mg/L by adding $NH_4Cl$. In terms of TSS and TCODcr removal efficiency, both systems with BCM and a system without BCM, respectively, had a similar level of the removal efficiency under varied HRTs of anoxic reactors (0.6 hr, 1.3 hr, 2 hr, 2 hr; control, without BC M) showing that varying an HRT of anoxic reactors did not affect the removal efficiency. While SCODcr removal efficiency of systems with BCM was improved approximately 4~5% at the same HRT of anoxic reactor, the removal efficiency of system with BCM was slightly decreased by reducing an HRT of anoxic reactor. The nitrification efficiency for both systems with BCM and a system without BCM was above 94% showing that packing BCM in aerobic reactors and varying an HRT of anoxic reactors did not affect the efficiency significantly despite of increasing $NH_4-N$ concentration of feed. The denitrification efficiency increased from 81.4% to 85.4% at system with BCM while the efficiency decreased when a shorter HRT of anoxic reactors was kept. The excellent effluent quality for $NO_3-N$ concentration was observed although the $NO_3-N$ concentration increased in anoxic reactors that $NH_4-N$ concentration of feed sufficiently converted into nitrate through nitrification. As a result, packing 20% BCM to an aerobic reactor with HRT of 1.3 hr of anoxic reactor in $A^2/O$ system can achieve a similar level of nitrogen removal efficiency in $A^2/O$ system which the aerobic reactor had no BCM and HRT of 2 hr for anoxic reactor is maintained.