• 제목/요약/키워드: Pachymeter

검색결과 3건 처리시간 0.015초

성공적인 굴절교정수술자 안구상태분석에 대한 연구 (The Analysis of the State of Successful Refractive Surgery's Eye)

  • 장우영;이정영;박정식
    • 한국임상보건과학회지
    • /
    • 제2권4호
    • /
    • pp.223-230
    • /
    • 2014
  • Purpose. Scheduled calibration of refractive error's have various refractive surgery, and a side effect of post refractive surgery for refractive errors's before refractive surgery, by analyzing the eye condition of the refractive error's good state, it tries to increase the satisfaction of refractive error's refractive surgery. Methods. In response to 60 people preoperative data 20-30 generations of age, were analyzed for eye conditions. Results. IOP, thickness of the cornea, liquid leakage amount inspection, the corneal endothelium inspection, the size of the pupil, have been conducted auto refraction test and showed a numerical value in most normal range. Conclusion. Surgery can be of individual differences of patients, it is difficult to define the full normal range, to the surgery based on the case of this study, the side effects of patients after surgery is expected to be prevention.

뉴질랜드 흰 토끼의 각막 두께, 내피세포 및 안압에 관한 조사 (Survey of Corneal Thickness, Endothelial Cell and Intraocular Pressure in New Zealand White Rabbits)

  • 장화석;이대엽;강은희;이재훈;조양경;김만수;김휘율
    • 한국임상수의학회지
    • /
    • 제27권4호
    • /
    • pp.411-414
    • /
    • 2010
  • Rabbit's cornea is the most common thing that used for researches in ophthalmology, so many experimentations have done. The purpose of this study was to survey the corneal pachymetry, tonometry and specular microscopy in New Zealand white rabbits. Three months old male rabbits ($2.9{\pm}0.2\;kg$) were examined with contact the specular microscope to evaluate the endothelial cell density, coefficiency of variation and the percentage of hexagonal cells in the central cornea. For the pachymetry, ultrasonic pachymeter was used for central cornea in each twenty rabbits, and tonometry was performed forty rabbit's eyes to evaluate the intraocular pressure. Corneal endothelial cell density in New Zealand white rabbit was $3304{\pm}354\;cell/mm^2$. Coefficiency of variation was $45.8{\pm}2$ and the percentage of hexagonal cells in the central cornea was $44.4{\pm}11%$. The pachymetry of cornea was $346.1{\pm}21\;{\mu}m$ and tonometry of eye was $14.3{\pm}2\;mmHg$. It is considered that normal New Zealand white rabbit's pachymetry, specular microscopy and tonometry were useful basic data of rabbit's cornea for research and clinic in veterinary ophthalmology.

20․30대 정상안과 콘택트렌즈 착용안의 각막 중심 두께 (Central Corneal Thickness of Normal Eyes and Contact Lens-wearing Eyes Aged in their 20s and 30s)

  • 박미정;박경선;안소연
    • 한국안광학회지
    • /
    • 제12권4호
    • /
    • pp.29-35
    • /
    • 2007
  • 본 연구는 착용하고 있는 콘택트렌즈의 종류에 따른 각막 중심 두께의 차이를 밝히고자 하였다. 20 30대 394명을 대상으로 초음파 각막 두께 측정계를 이용하여 각막 중심 두께를 측정하였다. 콘택트렌즈를 착용한 경험이 없는 Group 1의 각막 중심 두께는 성별 뿐만 아니라 좌우안 간에도 차이가 나타나지 않았으나, 굴절이상도가 높아질수록 얇아지는 경향을 보였다. 소프트콘택트렌즈만을 착용한 Group 2는 착용기간이 길어질수록 각막 중심 두께가 얇았으며, 10년 이상 착용안의 경우 4년 이하 착용안보다 각막 중심 두께가 유의하게 얇았다. 4년 이하의 기간 동안 RGP 렌즈만을 착용한 Group 3의 경우 소프트 콘택트렌즈만을 착용한 Group 2와 각막 중심 두께가 차이가 없었다. 또한, 소프트콘택트렌즈를 착용한 후 RGP 렌즈로 교체하여 사용하고 있는 Group 4와 Group 2의 각막 중심 두께를 비교하였을 때 통계적으로 유의한 차이가 없었다. 그러나, PMMA(polymethyl methacyrlate) 재질의 하드렌즈를 착용한 후 소프트 콘택트렌즈로 교체한 Group 5는 소프트 콘택트렌즈만을 착용한 Group 2에 비해 통계적으로 유의하게 각막 중심 두께가 얇았다.

  • PDF