• Title/Summary/Keyword: PWR steam generator

Search Result 66, Processing Time 0.04 seconds

Water Level Control of PWR Steam Generator using Knowledge Information and Fuzzy Logic at Low Power (전문가 지식과 퍼지 논리를 이용한 과도상태에서의 가압경수로 증기발생기 수위제어)

  • Han, Ho-Min;Choi, Dae-Won;Woo, Young-Kwang;Bae, Hyeon;Kim, Sung-Shin
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1295-1298
    • /
    • 2003
  • The steam generator level in a PWR is very difficult to control particularly at low power. And the constant control gain and time value are not adaptive in steam generator level controller. In normal operation constant control gain and time value have no problem. But there is problem at low power. So variable control gains based on the temperature are required. The best control gain is decided by the experienced knowledge. A fuzzy gain tuner is used for the gain tuning. In the design of fuzzy gain-tuner processing, the experienced knowledge is employed for making fuzzy rules.

  • PDF

Experimental studies on the fretting wear of domestic steam generator tubes (국내 증기발생기 전열관 마열에 대한 실험적 연구)

  • Lee, Yeong-Ho;Kim, Hyeong-Gyu;Kim, In-Seop
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.304-309
    • /
    • 2002
  • Fretting wear test in room temperature water was performed to evaluate the wear coefficient of Inconel 600,690 (Pressurized Water Reactor, PWR) and Alloy 800 (CANadian DeuteriumUranium, CANDU) steam generator (SG) tubes against ferritic and martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel alloys. Test conditions are $10{\sim}30N$ of normal load, $200{\sim}450{\mu}m$ of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between martensitic and ferritic stainless steel. The wear rate and wear mechanism of two tubes in room temperature water are discussed.

  • PDF

Numerical and analytical predictions of nuclear steam generator secondary side flow field during blowdown due to a feedwater line break

  • Jo, Jong Chull;Jeong, Jae-Jun;Moody, Frederick J.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.1029-1040
    • /
    • 2021
  • For the structural integrity evaluation of pressurized water reactor (PWR) steam generator (SG) tubes subjected to transient hydraulic loading, determination of the tube-to-tube gap velocity and static pressure distributions along the tubes is prerequisite. This paper addresses both computational fluid dynamics (CFD) and analytical approaches for predicting the tube-to-tube gap velocity and static pressure distributions during blowdown following a feedwater line break (FWLB) accident at a PWR SG. First of all, a comparative study on CFD calculations of the transient velocity and pressure distributions in the SG secondary sides for two different models having 30 or no tubes is performed. The result shows that the velocities of sub-cooled water flowing between any adjacent two tubes of a tubed SG model during blowdown can be roughly estimated by applying the specified SG secondary side porosity to those of the no-tubed SG model. Secondly, simplified analytical approximate solutions for the steady two-dimensional SG secondary flow velocity and pressure distributions under a given discharge flowrate are derived using a line sink model. The simplified analytical solutions are validated by comparing them to the CFD calculations.

Low-frequency modes in the fluid-structure interaction of a U-tube model for the steam generator in a PWR

  • Zhang, Hao;Chang, Se-Myong;Kang, Soong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1008-1016
    • /
    • 2019
  • In the SG (steam generator) of PWR (pressurized water reactor) for a nuclear plant, hundreds of U-shaped tubes are used for the heat exchanger system. They interact with primary pressurized cooling water flow, generating flow-induced vibration in the secondary flow region. A simplified U-tube model is proposed in this study to apply for experiment and its counterpart computation. Using the commercial code, ANSYS-CFX, we first verified the Moody chart, comparing the straight pipe theory with the results derived from CFD (computational fluid dynamics) analysis. Considering the virtual mass of fluid, we computed the major modes with the low natural frequencies through the comparison with impact hammer test, and then investigated the effect of pump flow in the frequency domain using FFT (fast Fourier transform) analysis of the experimental data. Using two-way fluid-structure interaction module in the CFD code, we studied the influence on mean flow rate to generate the displacement data. A feasible CFD method has been setup in this research that could be applied potentially in the field of nuclear thermal-hydraulics.

Analysis of steam generator tube rupture accidents for the development of mitigation strategies

  • Bang, Jungjin;Choi, Gi Hyeon;Jerng, Dong-Wook;Bae, Sung-Won;Jang, Sunghyon;Ha, Sang Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.152-161
    • /
    • 2022
  • We analyzed mitigation strategies for steam generator tube rupture (SGTR) accidents using MARS code under both full-power and low-power and shutdown (LPSD) conditions. In general, there are two approaches to mitigating SGTR accidents: supplementing the reactor coolant inventory using safety injection systems and depressurizing the reactor coolant system (RCS) by cooling it down using the intact steam generator. These mitigation strategies were compared from the viewpoint of break flow from the ruptured steam generator tube, the core integrity, and the possibility of the main steam safety valves opening, which is associated with the potential release of radiation. The "cooldown strategy" is recommended for break flow control, whereas the "RCS make-up strategy" is better for RCS inventory control. Under full power, neither mitigation strategy made a significant difference except for on the break flow while, in LPSD modes, the RCS cooldown strategy resulted in lower break and discharge flows, and thus less radiation release. As a result, using the cooldown strategy for an SGTR under LPSD conditions is recommended. These results can be used as a fundamental guide for mitigation strategies for SGTR accidents according to the operational mode.

A Study on Improvement of PWR Steam Generator Water Level Control at Low Power Operation (저출력시 원전 증기발생기 수위제어 개선 연구)

  • Yun, Jae-Hee;Han, Jai-Bok;Joon Lyou
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.420-424
    • /
    • 1994
  • This paper presents an improved water level control scheme for Pressurized Water Reactor(PWR) Steam Generator(S/G) at the low power operation and transient states. To reduce fluctuations of the water level by the swell and shrink phenomena, the scheme adds feedforward terms considering S/G pressure and the feedwater temperature into the conventional proportional-integral feedback controller. The simulation results using the Compact Nuclear Simulator show that smaller level errors and much faster settling time than those of the conventional scheme can be obtained. The proposed algorithm is easily implementable and has a potential for the real applications.

  • PDF

Generalized predictive control with feedforward and input constraints (입력제약과 선행신호를 고려한 일반형 예측제어기법)

  • 박상현;김창희;이상정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.327-330
    • /
    • 1996
  • It is well known that the controller output limits have a signifiant effect on the closed loop system performance. Considering the input constraints in GPCF, an effective selection method of the control weighting(.gamma.) is proposed to reduce the amplitude and the rate of control signals so that control signals lie within the limits. It is based on the relation between control weighting(.gamma.) and optimal solution of the unconstrained GPCF. The GPCFIC algorithm chooses an .gamma. at each sampling time so that all unconstrained GPCF output over the control horizon satisfy the rate and the amplitude constraints. In order to evaluate the performance of the GPCFIC, the computer simulations have been done for level control of PWR steam generator in low power operation and shown satisfactory results.

  • PDF

Detection and Diagnosis of Sensor Faults for Unknown Sensor Bias in PWR Steam Generator

  • Kim, Bong-Seok;Kang, Sook-In;Lee, Yoon-Joon;Kim, Kyung-Youn;Lee, In-Soo;Kim, Jung-Taek;Lee, Jung-Woon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.86.5-86
    • /
    • 2002
  • The measurement sensor may contain unknown bias in addition to the white noise in the measurement sequence. In this paper, fault detection and diagnosis scheme for the measurement sensor is developed based on the adaptive estimator. The proposed scheme consists of a parallel bank of Kalman-type filters each matched to a set of different possible biases, a mode probability evaluator, an estimate combiner at the outputs of the filters, a bias estimator, and a fault detection and diagnosis logic. Monte Carlo simulations for the PWR steam generator in the nuclear power plant are provided to illustrate the effectiveness of the proposed scheme.

  • PDF

Self-Tuning Predictive Control with Application to Steam Generator (증기 발생기 수위제어를 위한 자기동조 예측제어)

  • Kim, Chang-Hwoi;Sang Jeong lee;Ham, Chang-Shik
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.833-844
    • /
    • 1995
  • In self-tuning predictive control algorithm for steam generator is presented. The control algorithm is derived by suitably modifying the generalized predictive control algorithm. The main feature of the unposed method relies on considering the measurable disturbance and a simple adaptive scheme for obtaining the controller gain when the parameters of the plant are unknown. This feature makes the proposed approach particularly appealing for water level control of steam generator when measurable disturbance is used. In order to evaluate the performance of the proposed algorithm, computer simulations are done for an PWR steam generator model. Simulation result show satisfactory performances against load variations and steam flow rate estimation errors. It can be also observed that the proposed algorithm exhibit better responses than a conventional PI controller.

  • PDF