• Title/Summary/Keyword: PWM Wave

Search Result 189, Processing Time 0.031 seconds

A Study on the SHE PWM Inverter Using the Linearized Characteristics of Switching Angle for Carrier Wave (선형화한 스위칭각 특성파형을 반송파로 사용한 SHE PWM인버터에 관한 연구)

  • Kim, Kwon-Ho;Yoong, Kwan-Cheol;Song, Joong-Ho;Kim, Kwang-Bae;Lyou, Kyoung;Park, Gwi-Tae
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.7
    • /
    • pp.668-679
    • /
    • 1990
  • The fully digitalized inveter has some difficulties in implementation because of the limitation of available memory capacity and computation time. This paper describes a new PWM(Pulse Width Modulation) Inverter technique which linearizes switching angle characteristics of SHEPWM(Selected Harmonic Eliminatin Pulse Width Modulation) Inverter. Also the detailed description of the scheme along with the realization is presented. The simulation and experimental results show that the proposed schemes have the advantates such as good voltage waveforms and memory-saving.

  • PDF

A study on the haromnic attenuation of the BF Converter (BF 컨버터의 고조파 감쇠에 관한 연구)

  • 최태섭;안인수;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.8-15
    • /
    • 2000
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF(Boost Forward) converter with PWM-PFM(Pulse Width Modulation-Pulse Frequency Modulation) control technique to control DC output voltage, to remove the noise like harmonics at output voltage, and to control the input current with sinusoidal wave synchronized by the source voltage.To achieve the desired load voltage and improved PFC, we first implement current shaping control at the inverting stage and make the converted output DC voltage with forward converter. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. we control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally, we attenuated its harmonics and improved PF up to 0.96 using the current shaping technique.

  • PDF

A Fault Diagnosis on the Switching Mode Power Supply (스위칭 모드 파워 서플라이 건전성에 대한 진단)

  • Baik, Seung-Chan;Lee, Jin-Ho;Oh, Byung-Joo;Lee, Yung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.735-737
    • /
    • 2004
  • This paper proposes a method of fault diagnostics on switching mode power supply. When the error of switching mode power supply cannot be found when the conventional diagnostics is performed, this proposed method first performs diagnosis on the switching mode power supply strictly to judge the operating condition. This method analyzes the PWM wave which depends on the load change, to make sure the feedback control of the power supply to diagnosis the operation of the power supply system.

  • PDF

Sensorless Vector Control of Induction Motor Using Fuzzy PI Controller (퍼지 PI제어기를 이용한 유도전동기 속도 센서리스 벡터제어)

  • 남상현;이재환;김대균;김길동;이승환;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.390-393
    • /
    • 1999
  • For high performance ac drives, the speed sensorless vector control and a speed control algorithm base on the Fuzzy PI controller have received increasing attention. A Fuzzy PI controller is used for robust and fast speed control and space vector modulation method is used for PWM wave generation in this proposed system. The computer simulation results show that the proposed controller are more excellent control characteristics than conventional PI controller in transient-state response.

  • PDF

Analysis of current harmonics in the High PowerFactor Boost-type Rectifier (고역률 Boost-type 정류기의 고조파 분석)

  • Bae, Chang-Han;Lee, Kyo-Beum;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1969-1972
    • /
    • 1998
  • Harmonic analysis is important for PWM rectifiers with high powerfactor. This paper describes the harmonic analysis of input current in high powerfactor boost-type rectifier. The magnitudes of the harmonics are obtained through the current wave from analysis and the effect of source reactance is also analyzed.

  • PDF

Characteristics Analysis of Outer Rotor Type BLDC Motor according to Permanent Magnet Shade and Input Voltage Waveform (Permanent Magnet형상과 입력전압 파형에 따른 BLDC 전동기의 동특성해석)

  • Kim, Kyung-Ho;Choi, Geo-Seung;Kim, Myoung-Su;Chung, Koon-Seok;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.924-926
    • /
    • 2001
  • This paper presents the characteristics of current harmonics and torque ripple of Brushless DC motor, which is developed the fan blower of vehicles, according to permanent magnet shape input voltage wave form. To investigate the torque ripple and the phase current harmonics, these characteristics is analysed and compared the experimental results. In the process of analysis, FEM is introduced and computed a transient state torque of BLDC with a sinusoidal and a PWM wave voltage.

  • PDF

A Study on the Cell Culture Controller using the High Brightness LED (고휘도 LED를 이용한 세포배양 컨트롤러에 관한 연구)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Song, Chang-Hun;Mun, Seong-Pyo;Kim, Tae-Gon;Park, Yong-Pil;Kim, Dae-Young;Kim, Young-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1149-1153
    • /
    • 2006
  • We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage.

Study for the Design and Measurement of the High Voltage Pulse Generator Using Transformers (트랜스포머를 이용한 고전압 펄스 발생 장치의 설계와 측정평가에 관한 연구)

  • Kim, Young-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2012
  • High-capacity high-voltage pulse generator that can be used for environmental clean-up was developed using transformers. High-voltage pulse is consists of the primary wave and the harmonic wave which are increased as a series circuit using transformers to make pulses. Each transformer has a band-pass characteristics. The output voltage of the pulse width 50[%] was decided. The output voltage of high-voltage pulse generator device was measured as 1.4[kV] (Peak-to-Peak).

Implementation of the BLDC Motor Drive System using PFC converter and DTC (PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.62-70
    • /
    • 2007
  • In this paper, the boost Power Factor Correction(PFC) technique for Direct Torque Control(DTC) of brushless DC motor drive in the constant torque region is implemented on a TMS320F2812DSP. Unlike conventional six-step PWM current control, by properly selecting the inverter voltage space vectors of the two-phase conduction mode from a simple look-up table at a predefined sampling time, the desired quasi-square wave current is obtained, therefore a much faster torque response is achieved compared to conventional current control. Furthermore, to eliminate the low-frequency torque oscillations caused by the non-ideal trapezoidal shape of the actual back-EMF waveform of the BLDC motor, a pre-stored back-EMF versus position look-up table is designed. The duty cycle of the boost converter is determined by a control algorithm based on the input voltage, output voltage which is the dc-link of the BLDC motor drive, and inductor current using average current control method with input voltage feed-forward compensation during each sampling period of the drive system. With the emergence of high-speed digital signal processors(DSPs), both PFC and simple DTC algorithms can be executed during a single sampling period of the BLDC motor drive. In the proposed method, since no PWM algorithm is required for DTC or BLDC motor drive, only one PWM output for the boost converter with 80 kHz switching frequency is used in a TMS320F2812 DSP. The validity and effectiveness of the proposed DTC of BLDC motor drive scheme with PFC are verified through the experimental results. The test results verify that the proposed PFC for DTC of BLDC motor drive improves power factor considerably from 0.77 to as close as 0.9997 with and without load conditions.

A Design and Implementation of Circuit for Efficient Power LED Dimming Control (효율적인 고출력 LED 디밍 제어를 위한 회로 설계 및 구현)

  • Kim, Doo-Hyun;Choi, Jae-Ho;Cho, Beom-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2280-2288
    • /
    • 2014
  • The conventional dimming control methods of LED (Light-emitting dioades) include Analog, PWM (Pulse Width Modulation), and FM (Frequency Modulation) Control. Analog dimming is controlled by adjusting forward current of Power LED. Although Analog dimming is possible to control linearly the brightness levels on a whole range (0%~100%), it comes into existence a variation of wavelength by changing the Power LED's forward current. PWM dimming has achieved by varying in duty of full current flowing to the Power LED. Generally, PWM dimming doesn't make variation of wavelength but have difficulty with adjusting the linear brightness level between 0% and 10%. FM dimming method is on the same wavelength as PWM dimming, however, it has problem of flickering at low level of dimming. This paper propose a efficient dimming control method of Power LED in order to overcome the disadvantages of the above mentioned methods. We apply to Analog method in low level of dimming control and use PWM method in dimming range from 10% to 100%. For the experiment, we design and implement a circuit and test the proposed method. Consequently, we can control the linear brightness of Power LED across the whole range and get the constant wave at different dimming level. The experimental results show the benefits of the proposed method.