• Title/Summary/Keyword: PVDF film sensor

Search Result 65, Processing Time 0.036 seconds

Investigation on PVDE & PZT Sensor Signals for the Low-Velocity Impact Damage of Gr/Ep Composite Laminates (복합적층판의 저속충격손상에 따른 PZT 센서와 PVDF 센서의 신호 분석)

  • 이홍영;김진원;최정민;김인걸
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.125-128
    • /
    • 2003
  • Low-velocity impact damage is a major concern in the design of structures made of composite materials, because impact damage is hidden inside and cannot be detected by visual inspection. The piezoelectric thin film sensor can be used to detect variations in structural and material properties for structural health monitoring. In this paper, the PVDF and PZT sensors were used for monitoring impact damage initiation in Gr/Ep composite panel to illustrate this potential benefit. A series of impact test at various impact energy by changing impact mass and height is performed on the instrumented drop weight impact tester. The wavelet transform(WT) is used to decompose the piezoelectric sensor signals in this study. Test results show that the particular waveform of sensor signals implying the damage initiation and development are detected above the damage initiation impact energy. And it is found that both PZT and PVDF sensors can be used to detect the impact damage.

  • PDF

Monitoring of Low-velocity Impact Damage Initiation of Gr/Ep Panel 7sing Piezoeleetric Thin Film Sensor (압전필름센서를 이용한 복합재 평판의 저속충격 손상개시 모니터링)

  • 박찬익;김인걸;이영신
    • Composites Research
    • /
    • v.15 no.2
    • /
    • pp.11-17
    • /
    • 2002
  • The piezoelectric thin film sensor can be used to interpret variations in structural and material properties, e.g. for structural integrity monitoring and assessment. To illustrate one of this potential benefit, PVDF (polyvinylidene fluoride) film sensors are used for monitoring impact damage in Gr/Ep composite panels. Both PVDF film sensors and strain gages are attached to the surface of Gr/Ep specimens. A series of impact tests at various impact energy by changing impact mass the height are performed on the instrumented drop weight impact tester. The sensor responses are carefully examined to predict the onset of impact damage such as indentation, matrix cracking, and delamination, etc. Test results show that the particular waveforms of sensor signals implying the damage initiation and development are detected above the damage initiation impact energy. As expected, the PVDF film sensor is found to be more sensitive to impact damage initiation event than the strain gage.

High-Velocity Impact Damage Detection of Gr/Ep Composite Laminates Using Piezoelectric Thin Film Sensor Signals (압전필름센서 신호를 이용한 Gr/Ep 복합재 적층판의 고속충격 손상탐지)

  • Kim, Jin-Won;Kim, In-Gul
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.13-16
    • /
    • 2005
  • The mechanical properties of composite materials may degrade severely in the presence of damage. Especially, the high-velocity impact such as bird strike, a hailstorm, and a small piece of tire or stone during high taxing, can cause sever damage to the structures and sub-system in spite of a very small mass. However, it is not easy to detect the damage in composite plates using a single technique or any conventional methods. In this paper, the PYDF(polyvinylidene fluoride) film sensors and strain gages were used for monitoring impact damage initiation and propagation in composite laminates. The WT(wavelet transform) and STFT(short time Fourier transform) are used to decompose the sensor signals. A ultrasonic C-scan and a digital microscope are also used to examine the extent of the damage in each case. This research demonstrate how various sensing techniques, PVDF sensor in particular, can be used to characterize high-velocity impact damage in advanced composites.

  • PDF

8체질 맥법 검증을 위한 요골동맥 파형 측정 센서 개발

  • 문성수;정용원;이중재;공준웅;이흥세;전국진
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.9-12
    • /
    • 2001
  • In oriental medicine, it is possible to classify each person into eight kinds of constitutions based on the eight constitutional medicine theory. We developed a piezoelectric 3-channel tactile sensor using PVDF (polyvinylidene fluoride) film for pulse detection of the radial artery. High frequency buffer (impulse buffer), amplifier, 60 Hz noise notch filter and low pass filter were integrated on three sheets of PCB board. The pulses of the radial artery at three points were checked using our system. Each constitution of the eight ones has different combinations of pulses.

  • PDF

Unconstrained REM Sleep Monitoring Using Polyvinylidene Fluoride Film-Based Sensor in the Normal and the Obstructive Sleep Apnea Patients (PVDF 필름 기반 센서를 이용한 정상인 및 폐쇄성 수면 무호흡증 환자에서의 무구속적인 렘 수면 모니터링)

  • Hwang, Su Hwan;Yoon, Hee Nam;Jung, Da Woon;Seo, Sang Won;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.55-61
    • /
    • 2014
  • In sleep monitoring system, polysomnography (PSG) is the gold-standard but previous studies revealed that attaching numerous amount of sensors disturb sleep during the test which is the fundamental disadvantage of PSG. We suggest an unconstrained rapid-eye-movement (REM) sleep monitoring method measured with polyvinylidene (PVDF) film-based sensor for the normal and the obstructive sleep apnea (OSA) patients. Nine normal subjects and seventeen OSA patients have participated in the study. During REM sleep, rate and variability of respiration are known to be greater than in other sleep stages. Based on this phenomena, respiratory signals of participants were unconstrainedly measured using the PVDF-based sensor with the PSG and REM sleep were extracted from the average rate and variability of respiration. In epoch-by-epoch REM sleep detection, proposed method classified REM sleep with an average sensitivity of 72.3%, specificity of 92.5%, accuracy of 88.9%, and kappa statistic of 0.60 compared to the results of PSG. Student's t-test showed no significant difference between the results of normal and OSA group. This method is potentially applicable to REM sleep detection in homing environment or ambulatory monitoring.

Low Velocity Impact Monitoring for a Composite Sandwich Beam Using Piezo Thin Film Sensors (압전필름센서를 이용한 복합재 샌드위치 보의 저속충격 모니터링)

  • Park, Chan Ik;Lee, Gwan Ho;Kim, In Geol;Lee, Yeong Sin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.51-56
    • /
    • 2003
  • The piezoelectric thin film(PVDF: polyvinylidene fluoride) sensors having good dynamic sensing charachteristics can be used to monitor low vwlocit impact on composite structures. The impact response function for composite sandwich beam was derved. The impact tests at low energy without inducing damage were performed on the instrumented drop weight impact tester. The measured signals of PVDF sensors attached on the surface of the beam agreed well with the simulated signals. And the inverse technique was applied to reconstruct the impact forces from the PVDF sensor signals. Most of reconstructed impact forces showed good agreement with the measured forces. The comparison results showed that the piezoelectric thin film sensor can be used to monitor the low velocity impact on composite sandwich structures.

Unconstrained Estimation of Body Postures on Bed Using Polyvinylidene Fluoride Film-based Sensor (PVDF 필름 기반 센서를 이용한 무구속적인 누운 자세 추정)

  • Seo, Sangwon;Hwang, Su Hwan;Yoon, Hee Nam;Jung, Da Woon;Choi, Jae Won;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.169-176
    • /
    • 2014
  • As body postures on bed affects various sleep related diseases, it is considered as important information when monitoring sleeping in daily life. Though there have already been a few approaches to monitor body postures on bed conventionally, the development for simple and unconstrained methods is still needed to realize the long-term daily monitoring. Focusing on the fact that ballistocardiogram changes depending on the body postures on bed, we developed a novel method to estimate body posturesusing extremely simple, film-type ballistocardiogram sensor which is based on polyvinylidene fluoride(PVDF) film. With 10 subjects, we performed two experiments. One was for an estimation test to show that body postures on bed can be estimated by ballistocardiogram, and the other was for a reproducibility test to present the feasibility of ballistocardiogram based body postures monitoring. To estimate body postures on bed, we made an individual template set of body postures by designating one ballistocardiogram (BCG) sample as a template in each postures. Then, we calculated Pearson's correlation coefficients between a sample and each templates and estimated the body posture of the sample by choosing a posture which corresponds to the most significant correlation coefficients. As a result, we estimated body postures on bed with 99.2% accuracy in average and found that the estimation using ballistocardiogram is reproducible.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Acoustic Performance Enhancement in PVDF Speakers by Using Buckled Nanospring Carbon Nanotubes

  • Ham, Sora;Lee, Yun Jae;Kim, Jung-Hyuk;Kim, Sung-Ryong;Choi, Won Kook
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.360-365
    • /
    • 2019
  • A polyvinylidene fluoride (PVDF)-based film speaker is successfully fabricated with enhanced bass sound by incorporating buckled nanospring carbon nanotubes (NS-CNTs) as fillers. Various concentrations up to 1-7 wt% of uniformly dispersed buckled NS-CNTs are loaded to increase the beta (β)-phase fraction, crystallinity, and dielectric constant of the speaker, and this results in the bass part enhancement of about 19 dB full scale (dBFS) at 7 wt% filler loading of the piezoelectric film speaker.

Development of PVDF sensor and system to detect breathing sounds during deep sedation (진정 마취 시 호흡음 검출을 위한 PVDF 센서 및 시스템 개발)

  • Lee, Seung-Hwan;Li, Xiong;Im, Jae-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.153-159
    • /
    • 2019
  • Respiration is one of the important vital signs to determine the condition of the patient. Especially during deep sedation, since the patient's apnea and hypopnea are difficult to detect without continuous monitoring, there is a need for a continuous respiration monitoring method that can accurately and simply determine the patient's respiratory condition. Currently, respiration monitoring methods using various devices have been developed, but these methods have not only late response time but also low reliability at the clinical stage. In this study, attachable sensor using PVDF(polyvinylidene fluoride) film and a monitoring device which could detect abnormal symptoms of breathing in early stage during deep sedation. The results of this study can be used in various medical fields including not only in the area of remote monitoring for respiration related sleep monitoring but also in routine monitoring during deep sedation.