• Title/Summary/Keyword: PVC-membrane

Search Result 169, Processing Time 0.021 seconds

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.

A Study on the Silver Iodide Membrane Electrode (AgI / PVC${\cdot}$THF) (Ⅱ). Potentiometric Titration Error of Halide Mixture (요오드화은막전극 (AgI / PVC${\cdot}$THF) 에 관한 연구 (제2보). 할로겐화 이온혼합물의 전위차법 적정오차에 관한 연구)

  • Kee Chae Park;Young Soon Kwon
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.253-262
    • /
    • 1981
  • The AgI/ PV${\cdot}$THF membrane electrode could be used as an indicator electrode in the potentiometric titration of single halide and mixture halide solutions with the standard solution of silver nitrate. The errors in the stepwise titrations of mixture halide solutions were considerably large, but by addition of flocculating agent, such as $NaNO_3$ or $Ba(NO_3)_2$, in the sample solution, the errors were greatly reduced. Also, the effects of gelatin, filter paper and temperature on the titration errors were examined.

  • PDF

Selective transport of Cadmium by PVC/Aliquat 336 polymer inclusion membranes (PIMs): the role of membrane composition and solution chemistry

  • Adelung, Sandra;Lohrengel, Burkhard;Nghiem, Long Duc
    • Membrane and Water Treatment
    • /
    • v.3 no.2
    • /
    • pp.123-131
    • /
    • 2012
  • This study investigated the extraction and stripping performance of PIMs consisting of PVC and Aliquat 336. Extraction and stripping of three representative heavy metals - namely $Cd^{2+}$, $Cu^{2+}$, and $Zn^{2+}$ - by the synthesized membranes were evaluated as a function of sodium chloride concentration and under different stripping solutions (0.01 M $HNO_3$, Milli-Q water, 0.01 M HCl and 0.01 M NaOH), respectively. Results reported here indicate that the formation of negatively charged metal chloride complex species was responsible for the extraction of the target metal to PIMs. Experimental results and thermodynamic modeling of the speciation of chloro metal complexes further confirm that the extraction selectivity between $Cd^{2+}$, $Cu^{2+}$ and $Zn^{2+}$ can be controlled by regulating the chloride concentration of the feed solution. An acidic solution without any chloride was the most effective stripping solution, followed by Milli-Q water, and a diluted hydrochloric acid solution. On the other hand, the stripping of metals from PIMs did not occur when a basic stripping solution was used.

Basic Test on the Mechanical Characteristics of Polyester Membrane (폴리에스터 막재의 역학적 특성에 관한 기초시험)

  • Park, Kang-Geun;Yoon, Seoung-Hyun;Lee, Jang-Bok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of architectural membrane have fire proofing, lack of strength, tear resistance, durability and elasticity. For the estimation of this problems, it will be tested the basic mechanical properties of membrane material about tensile strength, tearing resistance and repeated loading behavior. Elastic modulus is 337.30~1257.63N/$mm^2$, and strain is 17.90~26.91%.

  • PDF

Synthesis of Porous $TiO_2$ Thin Films Using PVC-g-PSSA Graft Copolymer and Their Use in Dye-sensitized Solar Cells (PVC-g-PSSA 가지형 공중합체를 이용한 다공성 $TiO_2$ 박막의 합성 및 염료감응 태양전지 응용)

  • Byun, Su-Jin;Seo, Jin-Ah;Chi, Won-Seok;Shul, Yong-Gun;Kim, Jong-Hak
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.193-200
    • /
    • 2011
  • An amphiphilic graft copolymer comprising a poly(vinyl chloride) (PVC) backbone and poly (styrene sulfonic acid) (PSSA) side chains (PVC-g-PSSA) was synthesized via atom transfer radical polymerization (ATRP). Mesoporous titanium dioxide $(TiO_2)$ films with crystalline anatase phase were synthesized via a sol-gel process by templating PVC-g-PSSA graft copolymer. Titanium isopropoxide (TTIP), a $TiO_2$ precursor was selectively incorporated into the hydrophilic PSSA domains of the graft copolymer and grew to form mesoporous $TiO_2$ films, as confirmed by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. The performances of dye-sensitized solar cell (DSSC) were systematically investigated by varying spin coating times and the amounts of P25 nanoparticies. The energy conversion efficiency reached up to 2.7% at 100 mW/$cm^2$ upon using quasi-solid-state polymer electrolyte.

A PVC Liquid Membrane Electrodes for the Determination of Norfloxacin (PVC 액체막 전극을 이용한 Norfloxacin의 정량)

  • 김동오;남수자;문현숙;정문모;허문회;김대병;안문규
    • YAKHAK HOEJI
    • /
    • v.44 no.5
    • /
    • pp.406-410
    • /
    • 2000
  • The present method is to describe a potentiometric norfloxacin electrode system characterized by a membrane, based on the use of norfloxacin (NF) complex with ion-association reagents. These complexes were dissolved in DMSO, DMF acetonitrile or acetone and dispersed in plasticized poly(vinyl chloride) matrix. The picric acid complex electrode exhibited near-Nernstian response for NF in acetate buffer solution (pH 4.0) with a slope of 53.03 mV/decade. And linear response over the range of 10$^{-5}$ to 10$^{-3}$M solution of NE. The ingredients in tablet, capsule and biological important organic acids were not interfere.

  • PDF

Potential of Perchlorate Ion-Selective Electrode in PVC Membrane and Electrode Characteristics by ac Impedance (과염소산 이온선택성 PVC막 전극전위와 임피던스에 의한 전극특성)

  • 김경민;조경섭;강안수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.49-52
    • /
    • 1998
  • 1. 서론 : 화약이나 고체 충진제, 고체로\ulcorner 추진제의 산화제, slurry blasting agent 및 동물사료의 식품첨가제로 사용되고 있는 과염소산은 발화나 폭발성이 매우 강한 산화제로 정확한 순도를 측정하는 것은 중요하다. 용량분석법과 중량분석법에 비교하여 조작이 간단하고 편리한 과염소산이온의 농도를 직접 측정할 수 있는 PVC막 전극에 대한 많은 연구가 진행되고 있다. (생략)

  • PDF

Phase Separation Structure of (PVC/Liquid Crystal) Composite Membrane ((Polyvinylchloride/액정) 복합막의 상분리 구조)

  • 이미선;최성부;이한섭;박관선;김병식
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.68-69
    • /
    • 1998
  • 1. 서론 : 고분자/액정 복합막은 액정의 높은 분자운동성이 물질의확산에 기여하여 우수한 투과성을 나타낸다. 이 막은 3차원의 망상구조를 갖는 매트릭스 고분자내에 액정이 연속상으로 안정하게 분산된 상분리 구조를 가지고 있다. 이 복합막은 그러한 상분리 구조에 기인하여 자기지지형(self support LC) 복합막이라고도 한다. 복합막 중에 액정은 탄화수소가스에 대하여 높은 선택성을 나타내어 막속으로 흡착을 촉진하고 액정물질이 결정에서 액정으로 변화는 전이온도에서 투과계수가 100-200 증가한다고 보고하였다. (생략)

  • PDF

Characteristics of Gas Permeation of Alternative Laminated Membrane Perpared by Water-Casting (수면전개 교대적층막의 기체투과특성)

  • 남석태;최성부;김병식
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.04a
    • /
    • pp.15-18
    • /
    • 1991
  • 본 연구에서는 박막화를 위한 수면전개법을 이용하여 기체분리능을 향상시키기 위한 복합막을 개발하고자 수면전개 적층복합막을 제조하여 기체투과특성실험을 행하였다. 실험에 사용한 고분자재질은 투과성이 우수한 Cellulose Acetate(CA)와 Polystyrene(PS)을, 선택성이 우수한 Polyvinylchloride(PVC)이었다. 이들 막에 대한 적층형태와 방법에 대한 효과를 검토하고 blend막과도 기체투과특성을 비교하였다.

  • PDF

On the Behavior of Membrane Breakwaters in Waves (파랑중 막 구조 방파제의 거동 특성)

  • Cho, I.H.
    • Journal of Korean Port Research
    • /
    • v.8 no.1
    • /
    • pp.17-22
    • /
    • 1994
  • The wave interaction with flexible membrane such as PVC and fabrics is studied to prove its applicability to portable breakwaters. To obtain the wave exciting force acting on flexible membrane, eigen-function expansion method is employed. The effect of flexible is involved in body boundary condition in which x-directional displacement of membrane is obtained by solving the linear membrane equation. Displacement of membrane is assumed to be small compared to wavelength, therefore the tensile force of membrane remains constant. As the numerical examples, transmission and reflection coefficients according to the change of tensile forces are investigated. The hydrodynamic force on membrane, the dynamic tension in the mooring lines and the vertical displacement profile of membrane are also calculated. It is suggested that the flexible membrane can be used to engineering material for the future coastal/ocean applications.

  • PDF