• 제목/요약/키워드: PVC Tape

검색결과 11건 처리시간 0.01초

와이어링 PVC 테이프 내구 수명 예측 (Prediction Method of Useful Life of PVC Tape for Wiring Harness)

  • 김성우;정원욱;박종구;안미정
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권4호
    • /
    • pp.163-172
    • /
    • 2007
  • Phenomenon, such as hardening, cracking or breaking etc.. of PVC tape for wiring harness by aging were detected on driven automobile in field. Hardening or cracking of PVC tape were confirmed decline of elongation by surrounding stress. The accelerated heat aging test was carried out applying temperature most important factor of aging, and then deduced an equation of useful life using arrhenius model. Prediction method of useful life of PVC tape was developed using miner rule calculating damage value by thermal energy classified temperature by matching deduced equation of useful life and measured temperature value on driven automobile in field.

  • PDF

레이저 조사에 의한 endotracheal tubes의 안정성에 대한 연구

  • 정필상;김영훈;정필섭;이정구
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1995년도 이비인후과 종합학술대회 초록집
    • /
    • pp.91.2-91
    • /
    • 1995
  • 레이저를 이용한 구강 및 인후두 수술시 endotracheal tubes의 손상은 치명적이라 아니 할 수 없다. 이에 저자들은 여러 가지 endotracheal tube를 실험 재료로 사용하여 보다 안전한 레이저 수술을 위해서 적절한 endotracheal tube를 찾기 위해 본 실험을 시행하였다. 실험에 사용된 tube는 총 5가지 - $Bivona^{TM}$, Xomed Laser Shield $II^{TM}$, Mallinckrodt Laser-$Flex^{TM}$, Rusch tube wrapped with aluminium foil tape(Rusch tube), Polyvinylchloride tube wrapped with aluminium foil tape(PVC tube) - 가 사용되었다. 사용된 레이저는 KTP/532 와 $CO_2$ laser 이며 모든 실험에서 tube를 $FiO_2$ 95%-98% 상태에서 조사하여 각각 5회씩 실시하였다. tube에 이상이 없거나 발화가 되지 않는 한 90초 동안 시행하였다. 실험 결과, KTP/532 조사시 $Bivona^{TM}$, Mallinckrodt 와 PVC tube는 심한 손상을 받거나 발화하였으며 Xomed 와 Rusch tube는 안정된 상태를 유지하였고 $CO_2$ Laser 조사시는 KTP/532 조사시와 유사한 결과를 얻었다. 한편 혈액을 endotracheal tube에 도포한 상황에서는 모든 tube가 더 심한 손상을 보이는 바 KTP/532 조사시 Xomed는 상당히 안정된 상태를 유지하였고 나머지 tube는 심한 손상 또는 발화를 보이고 $CO_2$ Laser 조사시 $Bivona^{TM}$ 와 Mallinckrodt는 발화하였고 Rusch tube는 표면이 녹았으며 Xomed와 PVC tube도 1례에서 발화하였다. 향후 이비인후과 영역에서의 레이저 수술이 증가함을 예상할 때 좀 더 레이저에 대하여 안정적이고 경제적인 endotracheal tube의 개발이 필요할 것으로 사료된다.

  • PDF

에어컨 전선 마감 Tape 변색 및 냄새에 관한 고장분석 사례 (Failure Analysis of the Masking Tape for Airconditioner)

  • 서성미;최동준;박상득
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제5권4호
    • /
    • pp.405-412
    • /
    • 2005
  • In this paper, we verified the failure mechanism of the discolored masking tape wrapped around the wire and studied an improved case study as well. Masking tapes are poly(Vinylchloride-co-Methyl methacrylate) (PVC) and the wire connecting with indoor/outdoor components of the air conditioner is chloroprene(CR). The masking tape under. the ultraviolet ray was accelerated to discolor fivefold. The results determined reveal the discoloration of masking tapes as an elution of the additives, dephenyl Amine series antioxidants, in the connecting wire. When changed dephenyl Amine series to phenol series, we found that the degree of discoloration was dramatically decreased. Due to stink of Thiourea and Thiuram monosulfide, as accelerators in CR wire, we controlled the vulcanization temperature and time without using these accelerators and could get the wire not to smell bad with the equal mechanical properties.

  • PDF

TDR센서를 이용한 터널 지보재의 모형 실험과 거동해석 (Model Experiments and Behavior Analyses of The Tunnel Support Using TDR Sensor)

  • 박민철;한희수;조재호;양남용
    • 한국지반환경공학회 논문집
    • /
    • 제12권9호
    • /
    • pp.35-45
    • /
    • 2011
  • 본 연구에서는 터널 지보재의 거동을 전기펄스를 이용한 계측 시스템인 TDR센서를 이용하여 파악하고자 하였다. 터널 지보재의 거동을 파악하기 위해 먼저 구리테이프를 TDR센서의 계측재료로 이용하여 터널 지보재에 설치하기 위한 제작기법에 대해 연구하였다. 그 결과 구리테이프의 상부에 유리테이프, 하부에 스티로폼+전자파 차단시트를 설치했을 때 TDR센서의 민감도가 적절했고 노이즈 발생량도 적었다. PVC파이프 터널모형단면을 통해 단면의 강성과 지점 조건에 따라 데이터의 형태가 어떠한 경향을 나타내는 지 확인할 수 있었다. 이는 실제 현장에 구리테이프를 이용하여 터널 지보재의 거동을 정확히 파악하기 위해서는 지보재의 강성과 지점 조건을 현장과 동일하게 하여야 함을 알 수 있었다. TDR데이터와 유한요소해석과의 비교를 통해 TDR센서를 이용하여 터널의 거동을 파악할 수 있음을 알 수 있다. TDR데이터를 통해 지보재의 변형을 정성적으로 파악할 수 있고, 응력과 변형률 관계를 통해 지보재의 부재력까지 파악할 수 있을 것으로 기대된다.

자외선이 차단되는 창문용 점착시트 개발에 관한 연구 (The Development of UV Blocking Type Pressure-Sensitive Adhesive Sheet for Window)

  • 김성호
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.559-564
    • /
    • 2011
  • PVC 기재에 자외선 차단제를 첨가하는 종래의 방법 대신, 점착제에 차단제를 혼합하여, 유리창에 부착하는 창문용 점착시트를 제조 하였다. 무기계차단제와 유기계차단제를 모두 사용 하였으며, 파장 280-400 nm 구간에서 흡광도를 측정하여 자외선 차폐성능을 평가하였다. 무기계보다는 유기계차단제의 성능이 우수하였으며, 1%만 첨가하여도 투명도나 점착력에는 영향을 주지 않고 대부분의 자외선을 차단하였다.

방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능 (Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System)

  • 오창원
    • 한국건축시공학회지
    • /
    • 제18권5호
    • /
    • pp.463-469
    • /
    • 2018
  • 기존의 다층으로 구성되어 시공성이 낮은 옥상녹화 공법의 개선을 위해 개발한 방수 방근 시트 일체화 옥상녹화박스 유닛공법의 일체화를 위해 사용하는 전자기 유도가열방식의 금속 고정구와 콘 형상 고정구의 부착성능을 평가하기 위해 엔지니어링 PE, TPO, PVC 시트 등 3종류의 시트에 가열온도에 따른 부착성능 및 동일한 시험체로 냉열반복 후 부착성능을 측정하였다, 그 결과는 엔지니어링 PE시트에 부착한 고정구의 부착성능이 가장 우수하게 나타났으며, 금속고정구는 가열온도가 올라갈수록, 콘 형상 고정구는 가열온도가 낮을수록 우수한 부착성능을 보여주었고, 냉열 반복 후 부착시험 결과는 상온 부착시험 결과와 동일하게 나타났다. 기존의 양면 부틸테이프 고정방식의 콘 형상 고정구는 낮은 부착하중과 냉열반복에 의한 뚜렷한 성능저하가 발생하는데 비하여 전자기 유도가열방식의 고정구는 우수한 성능을 유지하였다.

감마선 조사와 저장 기간에 따른 건멸치류의 품질 및 열발광 특성 (Quality and Thermoluminescence Properties of ${\gamma}$-Irradiated Boiled-Dried Anchovies during Storage)

  • 권중호;노정은;변명우
    • 한국식품저장유통학회지
    • /
    • 제9권1호
    • /
    • pp.19-27
    • /
    • 2002
  • 건멸치의 위생적 품질개선을 위한 감마선 조사가 품질에 미치는 영향을 조사하였으며, 아울러 감마선 조사 멸치에 대한 검 지법으로서 열발광 특성을 분석하였다. 건멸치류의 미생물 오염도는 총세균이 $10^4$~$10^{6}$ CFU/g 수준으로 건멸치의 종류에 따라 큰 타이를 보였으며, 대장균군은 모든 시료에서 음성으로 나타났다. 미생물학적 품질개선을 위한 3kGy 수준의 감마선 조사는 유통조건(식품포장용 PVC film, 0.06 mm, 500 g)으로 포장하여 6개월 저장(15$\pm$1$^{\circ}C$) 후에도 검출한계이하(20 CFU/g)의 수준을 유지할 수 있었다 저장 중 건멸치의 기계적색도(L, a, b, ΔE ), 갈색도, TBA가, VBN, TMA-N, 관능적 특성 등 건멸치의 품질에 관련된 여러 인자들은 3 kGy의 감마선 조사에 의해 거의 영향을 받지 않았다. 그러나 저장기간에 따른 영향은 매우 크게 나타났으며, 이는 저장온도와 포장조건의 중요성을 뒷받침해 주었다. 건멸치의 방사선 조사 여부 확인을 위한 열발광 특성을 분석해 본 결과, 비조사구는 280~30$0^{\circ}C$ 부근에서 매우 낮은 peak를 나타내었고, 1 kGy 이상의 감마선 조사구는 20$0^{\circ}C$ 전후에서 조사선량에 의존적($R^2$=0.9933)인 높은 glow curve를 나타내어 감마선 조사 건멸치의 판별이 가능하였고, - 2$0^{\circ}C$에서 6개월간 저장 후에도 검지가 가능하였다.

EM Radioautographic Techniques에 관(關)한 연구(硏究) - Cork 방법(方法) - (An Improved Method for EM Radioautographic Techniques using Cork)

  • 김명국
    • Applied Microscopy
    • /
    • 제10권1_2호
    • /
    • pp.7-17
    • /
    • 1980
  • Electron microscope radioautography introduced by Liquier-Milward (1956) is now used routinely in many laboratories. Most of the technical difficulties in specimen preparation have been overcome. This method is modified from loop method for improvement of EM radioautographic techniques. The advantages of this method are: 1. the use of single specimens on small corks and of a large wire loop, allows the experimenter to avoid the blemishes in the membrane; 2. the surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4, thus greatly prolonging the period of time over which good emulsion layers can be made; 3. corks can be handled in perspex holder which allows about 20 specimens to be developed simultaneously. The steps of the method comprise: 1. Cut ribbons of ultrathin sections of silver interference colour 2. Pick them up on formvar-coated 200 mesh grids 3. Prestaining of tissues 4. Coat the specimens with a thin layer of carbon by evaporation (30-60A) 5. Mount the specimens on corks (about 1cm apical diameter) using double-sided scotch tape 6. Emulsion coating; a. Take a 250m1 beaker, place it on the pan of a sliding weight balance and weigh it. Add 10 grams extra to the beam. Add pieces of ILford L4 emulsion to the beaker until the balance is swinging freely. Add the 20ml of distilled water that was previously measured out. b. Surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4. 7. Prepare a series of membranes of gelled emulsion with the wire loop and apply one to each cork-borne specimen. 8. Put the specimens away to expose by pushing the corks into short length of PVC tubing, each tube having a small hole in the side 9. Place the tubes in small boxes together with silica gel. 10. Exposure 11. Developer - Kodak Microdol X for 3 minutes 12. Fixer - A perspex holder can be manufactured which allows 20 specimens to be developed simultaneously. 12. Fixer - 30% sodium thiosulfate for 10 minutes 13. Examination with Siemens Elmiskop 1A electron microscope

  • PDF

애견 더미 개발 (Development of Pet Dog's Dummy)

  • 이예리;장정아
    • 한국의류산업학회지
    • /
    • 제20권2호
    • /
    • pp.219-225
    • /
    • 2018
  • The purpose of this study is to make an ideal dummy for adult Maltese with proper investigation of its character and direct measurement of dog body-shape. The results of the study are as follows; First, there were 6 factors to affect the characteristics of Maltese body in the analysis, which are size of body, leg shape, chest shape, leg thickness, body length, length between fore-legs. In the cluster analysis with the 6 factors there were two types of Maltese body. Type 1 has body characteristics with large body, thick leg, and small distance between front legs. Type 2 has average size of all factors including body size, leg thickness, and length between fore-legs. Second, type 2 was selected as a representative one to make a dummy reflected body shape of characteristics because it took 67.71% from entire considered factors and has average value in the measured size. The first dummy pattern was planned by copying the surface area of the representative body shape with the method of surgical tape. A dummy of single body with trunk and legs was made using 30's cotton cloth, polyester inside batting, compressed form PVC and metallic wire on the joint of trunk and legs to support dummy shape. The second pattern was made by correcting size difference of the pattern and adding the pattern of neck covering plate, metal magnetic button was inserted on the center of joint area of trunk and legs to make detachable legs for easy slip on and off the pet's wear.

냉감 기능성 댄스스포츠 웨어 개발에 관한 연구 (A Study on the Development of Dance Sportswear with Cool-touch Function)

  • 전미화;장정아;구영석
    • 한국의류산업학회지
    • /
    • 제22권1호
    • /
    • pp.66-75
    • /
    • 2020
  • This study helps develop cool-touch functional dance sportswear. We suggest a draft design for dance sportswear that chooses appropriate cool-touch functional materials based on an investigation of the changes of body surface temperature before and after exercise, the physical properties of cool-touch materials on the market, and the preference for cooling tools. The results are as follows. First, cool-touch functional sportswear products on the market utilize materials such as PCM, Delta fabric, high gauge fabric, and ice chips as well as incorporate functions such as UV block and eyelets for enhanced breathability. Polyester and polyurethane fibers are mainly used for cool-touch functional sportswear. Second, the neck area showed the highest surface temperatures (32.7℃ and 32.1℃) before and after exercise. Body surface temperatures measured after exercise were also lower than temperatures measured before exercise when wearing dance sportswear. Third, as for the physical properties of cool-touch materials, material 1 showed amaximum drying speed (130 min), material 3 the best moisture absorption speed (122 × 132 min), and material 4 the best thermal conductivity (0.013 7 w/m·K). Fourth, a draft design for a cool-touch functional dance sportswear was suggested, including a neckband made of removable soft PVC material on the neck area and applying material 4 in F1, B4, S2 and lower arm areas and material 1 in the armpit area. Deodorant tape was also attached to the armpit area for added comfort and antibacterial deodorant effect.