• Title/Summary/Keyword: PVC Tape

Search Result 11, Processing Time 0.027 seconds

Prediction Method of Useful Life of PVC Tape for Wiring Harness (와이어링 PVC 테이프 내구 수명 예측)

  • Kim, Seong-Woo;Jung, Won-Wook;Park, Jong-Koo;Ahn, Mi-Jung
    • Journal of Applied Reliability
    • /
    • v.7 no.4
    • /
    • pp.163-172
    • /
    • 2007
  • Phenomenon, such as hardening, cracking or breaking etc.. of PVC tape for wiring harness by aging were detected on driven automobile in field. Hardening or cracking of PVC tape were confirmed decline of elongation by surrounding stress. The accelerated heat aging test was carried out applying temperature most important factor of aging, and then deduced an equation of useful life using arrhenius model. Prediction method of useful life of PVC tape was developed using miner rule calculating damage value by thermal energy classified temperature by matching deduced equation of useful life and measured temperature value on driven automobile in field.

  • PDF

레이저 조사에 의한 endotracheal tubes의 안정성에 대한 연구

  • 정필상;김영훈;정필섭;이정구
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1995.04a
    • /
    • pp.91.2-91
    • /
    • 1995
  • 레이저를 이용한 구강 및 인후두 수술시 endotracheal tubes의 손상은 치명적이라 아니 할 수 없다. 이에 저자들은 여러 가지 endotracheal tube를 실험 재료로 사용하여 보다 안전한 레이저 수술을 위해서 적절한 endotracheal tube를 찾기 위해 본 실험을 시행하였다. 실험에 사용된 tube는 총 5가지 - $Bivona^{TM}$, Xomed Laser Shield $II^{TM}$, Mallinckrodt Laser-$Flex^{TM}$, Rusch tube wrapped with aluminium foil tape(Rusch tube), Polyvinylchloride tube wrapped with aluminium foil tape(PVC tube) - 가 사용되었다. 사용된 레이저는 KTP/532 와 $CO_2$ laser 이며 모든 실험에서 tube를 $FiO_2$ 95%-98% 상태에서 조사하여 각각 5회씩 실시하였다. tube에 이상이 없거나 발화가 되지 않는 한 90초 동안 시행하였다. 실험 결과, KTP/532 조사시 $Bivona^{TM}$, Mallinckrodt 와 PVC tube는 심한 손상을 받거나 발화하였으며 Xomed 와 Rusch tube는 안정된 상태를 유지하였고 $CO_2$ Laser 조사시는 KTP/532 조사시와 유사한 결과를 얻었다. 한편 혈액을 endotracheal tube에 도포한 상황에서는 모든 tube가 더 심한 손상을 보이는 바 KTP/532 조사시 Xomed는 상당히 안정된 상태를 유지하였고 나머지 tube는 심한 손상 또는 발화를 보이고 $CO_2$ Laser 조사시 $Bivona^{TM}$ 와 Mallinckrodt는 발화하였고 Rusch tube는 표면이 녹았으며 Xomed와 PVC tube도 1례에서 발화하였다. 향후 이비인후과 영역에서의 레이저 수술이 증가함을 예상할 때 좀 더 레이저에 대하여 안정적이고 경제적인 endotracheal tube의 개발이 필요할 것으로 사료된다.

  • PDF

Failure Analysis of the Masking Tape for Airconditioner (에어컨 전선 마감 Tape 변색 및 냄새에 관한 고장분석 사례)

  • Seo, Sung-Mi;Choi, Dong-Jun;Park, Sang-Dunk
    • Journal of Applied Reliability
    • /
    • v.5 no.4
    • /
    • pp.405-412
    • /
    • 2005
  • In this paper, we verified the failure mechanism of the discolored masking tape wrapped around the wire and studied an improved case study as well. Masking tapes are poly(Vinylchloride-co-Methyl methacrylate) (PVC) and the wire connecting with indoor/outdoor components of the air conditioner is chloroprene(CR). The masking tape under. the ultraviolet ray was accelerated to discolor fivefold. The results determined reveal the discoloration of masking tapes as an elution of the additives, dephenyl Amine series antioxidants, in the connecting wire. When changed dephenyl Amine series to phenol series, we found that the degree of discoloration was dramatically decreased. Due to stink of Thiourea and Thiuram monosulfide, as accelerators in CR wire, we controlled the vulcanization temperature and time without using these accelerators and could get the wire not to smell bad with the equal mechanical properties.

  • PDF

Model Experiments and Behavior Analyses of The Tunnel Support Using TDR Sensor (TDR센서를 이용한 터널 지보재의 모형 실험과 거동해석)

  • Park, Min-Cheol;Han, Heui-Soo;Cho, Jae-Ho;Yang, Nam-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.35-45
    • /
    • 2011
  • This paper is to analyze the behaviors of tunnel support by TDR(Time Domain Reflectometry) sensor using electrical pulse. To analysis the behaviors of tunnel support, Copper tape as sensing materials was studied for on-site installation. Copper tape to the top of the glass tape, foam tape, and shielding the lower part was used electromagnetic shield sheet. For a high sensitivity to load and fill out the measurement noise emissions has been developed for the production of materials. This sensing material through the tunnel model tests for the change by surcharge load in TDR data were analyzed. Varing stiffness and support of conditions were determined the change of TDR data through PVC pipe tunnel section model tests. By comparing TDR data and finite element analysis, the behaviors of the tunnel support materials were analyzed qualitatively.

The Development of UV Blocking Type Pressure-Sensitive Adhesive Sheet for Window (자외선이 차단되는 창문용 점착시트 개발에 관한 연구)

  • Kim, Sung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.559-564
    • /
    • 2011
  • The UV blocking type pressure-sensitive adhesive sheet was developed by mixing UV blocking reagent with adhesive material, instead of conventional method in which the reagent was mixed with PVC substrate. The blocking performance of the sheet was evaluated by measuring the absorbance in 280-400 nm region. Both organic and inorganic type blocking reagents were examined. The blocking ability of the former is better than that of the later. Only 1% addition of blocking reagents is effective to block UV light without affecting to visibility and tackiness of adhesive tapes.

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.

Quality and Thermoluminescence Properties of ${\gamma}$-Irradiated Boiled-Dried Anchovies during Storage (감마선 조사와 저장 기간에 따른 건멸치류의 품질 및 열발광 특성)

  • 권중호;노정은;변명우
    • Food Science and Preservation
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2002
  • The effect of gamma irradiation was investigated on the microbiological and physicochemical qualities of boiled-dried anchovies (large- and smallsized) packed in PVC film (0.06 ㎜) during storage at 15$\pm$1$\^{C}$ for 6 months. On the other hand, thermoluminescence characteristics of minerals extracted from the sample were analyzed to evaluate its possibility in detecting the irradiated anchovies. The samples were contaminated by microbial levels of 104∼106 CFU/g in total aerobic bacterial counts and negative in coliforms, which were different depending on the sample sizes. Gamma irradiation at 3 kGy was effective for improving the hygienic quality of both samples for 6 months, keeping the microbial population less than 20 CFU/g. Besides it was not detrimental to the quality attributes, such as instrumental color parameters L, a, b, ΔE), browning, TBA value, volatile basic nitrogen, trimethylamine-N and sensory properties(appearance, color, odor, tape, overall acceptability). However, storage conditions (time, temperature, packing) showed a critical factor nfluencing the quality changes of dried anchovies. Thermoluminscence analysis was prove to distinguish irradiated from non-irradiated anchovies by comparing both temperature at which glow curves appear and the curve intensity, that was possible even after 6 months at - 20$\^{C}$.

An Improved Method for EM Radioautographic Techniques using Cork (EM Radioautographic Techniques에 관(關)한 연구(硏究) - Cork 방법(方法) -)

  • Kim, Myung-Kook;Hassler, R.
    • Applied Microscopy
    • /
    • v.10 no.1_2
    • /
    • pp.7-17
    • /
    • 1980
  • Electron microscope radioautography introduced by Liquier-Milward (1956) is now used routinely in many laboratories. Most of the technical difficulties in specimen preparation have been overcome. This method is modified from loop method for improvement of EM radioautographic techniques. The advantages of this method are: 1. the use of single specimens on small corks and of a large wire loop, allows the experimenter to avoid the blemishes in the membrane; 2. the surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4, thus greatly prolonging the period of time over which good emulsion layers can be made; 3. corks can be handled in perspex holder which allows about 20 specimens to be developed simultaneously. The steps of the method comprise: 1. Cut ribbons of ultrathin sections of silver interference colour 2. Pick them up on formvar-coated 200 mesh grids 3. Prestaining of tissues 4. Coat the specimens with a thin layer of carbon by evaporation (30-60A) 5. Mount the specimens on corks (about 1cm apical diameter) using double-sided scotch tape 6. Emulsion coating; a. Take a 250m1 beaker, place it on the pan of a sliding weight balance and weigh it. Add 10 grams extra to the beam. Add pieces of ILford L4 emulsion to the beaker until the balance is swinging freely. Add the 20ml of distilled water that was previously measured out. b. Surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4. 7. Prepare a series of membranes of gelled emulsion with the wire loop and apply one to each cork-borne specimen. 8. Put the specimens away to expose by pushing the corks into short length of PVC tubing, each tube having a small hole in the side 9. Place the tubes in small boxes together with silica gel. 10. Exposure 11. Developer - Kodak Microdol X for 3 minutes 12. Fixer - A perspex holder can be manufactured which allows 20 specimens to be developed simultaneously. 12. Fixer - 30% sodium thiosulfate for 10 minutes 13. Examination with Siemens Elmiskop 1A electron microscope

  • PDF

Development of Pet Dog's Dummy (애견 더미 개발)

  • Lee, Ye-Ri;Jang, Jeong-Ah
    • Fashion & Textile Research Journal
    • /
    • v.20 no.2
    • /
    • pp.219-225
    • /
    • 2018
  • The purpose of this study is to make an ideal dummy for adult Maltese with proper investigation of its character and direct measurement of dog body-shape. The results of the study are as follows; First, there were 6 factors to affect the characteristics of Maltese body in the analysis, which are size of body, leg shape, chest shape, leg thickness, body length, length between fore-legs. In the cluster analysis with the 6 factors there were two types of Maltese body. Type 1 has body characteristics with large body, thick leg, and small distance between front legs. Type 2 has average size of all factors including body size, leg thickness, and length between fore-legs. Second, type 2 was selected as a representative one to make a dummy reflected body shape of characteristics because it took 67.71% from entire considered factors and has average value in the measured size. The first dummy pattern was planned by copying the surface area of the representative body shape with the method of surgical tape. A dummy of single body with trunk and legs was made using 30's cotton cloth, polyester inside batting, compressed form PVC and metallic wire on the joint of trunk and legs to support dummy shape. The second pattern was made by correcting size difference of the pattern and adding the pattern of neck covering plate, metal magnetic button was inserted on the center of joint area of trunk and legs to make detachable legs for easy slip on and off the pet's wear.

A Study on the Development of Dance Sportswear with Cool-touch Function (냉감 기능성 댄스스포츠 웨어 개발에 관한 연구)

  • Jun, Mi-Hwa;Jang, Jeong-Ah;Koo, Young-Seok
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.66-75
    • /
    • 2020
  • This study helps develop cool-touch functional dance sportswear. We suggest a draft design for dance sportswear that chooses appropriate cool-touch functional materials based on an investigation of the changes of body surface temperature before and after exercise, the physical properties of cool-touch materials on the market, and the preference for cooling tools. The results are as follows. First, cool-touch functional sportswear products on the market utilize materials such as PCM, Delta fabric, high gauge fabric, and ice chips as well as incorporate functions such as UV block and eyelets for enhanced breathability. Polyester and polyurethane fibers are mainly used for cool-touch functional sportswear. Second, the neck area showed the highest surface temperatures (32.7℃ and 32.1℃) before and after exercise. Body surface temperatures measured after exercise were also lower than temperatures measured before exercise when wearing dance sportswear. Third, as for the physical properties of cool-touch materials, material 1 showed amaximum drying speed (130 min), material 3 the best moisture absorption speed (122 × 132 min), and material 4 the best thermal conductivity (0.013 7 w/m·K). Fourth, a draft design for a cool-touch functional dance sportswear was suggested, including a neckband made of removable soft PVC material on the neck area and applying material 4 in F1, B4, S2 and lower arm areas and material 1 in the armpit area. Deodorant tape was also attached to the armpit area for added comfort and antibacterial deodorant effect.