• 제목/요약/키워드: PVC Membrane

검색결과 169건 처리시간 0.018초

Salicylate-Selective Electrodes Based on Tripodal Tris-thiourea Derivatives

  • Lee, Chaeg-Yeong;Kim, Jung-Hwan;Kim, Dong-Wan;Lee, Shim-Sung;Kim, Jin-Eun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2466-2470
    • /
    • 2007
  • A new highly salicylate-selective PVC membrane electrode based on tripodal tris-thiourea derivatives, L1 and L2, as neutral carriers is described. The electrodes display an excellent potentiometric response to salicylate ions and an anti-Hofmeister selectivity sequence in the following order: Salicylate? > ClO4 ? > Benzoate? > I? >NO3? > NO2? > Maleate? > Acetate? > Lactate? > Fumarate?. It also exhibited a near-Nernstian potential in a linear range of 5.0 × 10?5 - 1.0 × 10?1 M with a detection limit of 9.0 × 10?5 mol/L and a slope of ?59.9 mV/decade at a pH of 7.0 in a saline buffer solution at 25 oC. The stability constant (log KS) of the anionsionophore complex was also determined at 25 oC by a conductometric titration in DMSO solution.

Enhancement of the Ionic Conductivity and Mechanical Strength of Micro-porous Separator by Uni-axial Drawing

  • Lee Je-An;Seol Wan-Ho;Lee Yong-Min;Park Jung-Ki
    • 전기화학회지
    • /
    • 제9권1호
    • /
    • pp.29-33
    • /
    • 2006
  • A new porous separator based on poly(vinyl chloride) (PVC)/poly(vinylidene fluoride-co-hexafluoro-propylene) (P(VdF-co-HFP)/poly(methyl methacrylate) (PMMA) was prepared by a phase inversion method. To enhance mechanical property, the membrane was stretched uniaxially at high temperature. Tensile strength and ionic conductivity were measured for various draw ratios. The tensile strength and ionic conductivity were increased with increasing draw ratio. The tensile strength of the separator reached 52MPa after stretching to draw ratio of 5, and the ionic conductivity of the separator was increased from $1.9Xs10^{-4}S/cm\;to\;4.6X10^{-4}S/cm\;at\;25^{\circ}C$. The stretched separator immersed in liquid electrolyte was electrochemically stable up to 4.7 V. The cell based on the stretched separator was maintained at about 99% of the initial discharge capacity after 10th cycle operation at 0.2C rate.

New Separators Based on Non-Polyolefin Polymers for Secondary Lithium Batteries

  • Seol, Wan-Ho;Lee, Yong-Min;Lee, Jun-Young;Han, Young-Dal;Ryu, Myung-Hyun;Park, Jung-Ki
    • 전기화학회지
    • /
    • 제10권2호
    • /
    • pp.82-87
    • /
    • 2007
  • New porous separators based on non-polyolefin materials including the blend of poly (vinyl chloride) (PVC)/poly (vinylidene fluoride-co-hexafluoropropylene) (P(VdF-co-HFP)/poly(methyl methacrylate) (PMMA), and the porous separator based on poly (vinylidene fluoride) (PVdF) were prepared by phase inversion method. The porosity and morphology were controlled with phase inversion rate, which is governed by the relative content of non-solvent and solvent in coagulation bath. To enhance tensile strength, the solvent pre-evaporation and uni-axial stretching processes were applied. The ionic conductivity was increased with increasing stretching ratio, and tensile strength was increased with increasing solvent pre-evaporation time and stretching ratio. The 200% stretched PVdF separator showed 56 MPa of tensile strength, and the ionic conductivity of the stretched PVdF separator was $8.6{\times}10^{-4}\;S\;cm^{-1}\;at\;25^{\circ}C$.

H$^+$ 선택성 막 전극을 이용한 바이오센서의 감응 특성 (Characteristic Responses of Biosensor Based on $H^+$-Selective Membrance Electrode)

  • 김기묘;박성배;황명석;허문회;안문규
    • 약학회지
    • /
    • 제40권6호
    • /
    • pp.625-631
    • /
    • 1996
  • The $H^+$-selective membrane consists of tridodecylamine, 2-nitrophenyl octyl ether and a little amount of additive in carboxylated PVC matrix, where penicillinase(Pcase ) and glutaraldehyde may be covalently attached to the matrix. When the $H^+$-selective electrode was used as a detector of biosensor, calibration curve calculated from Nernst equation was not linear. So we investigated the characteristic responses of the $H^+$-selective electrode to the product H+ from hydrolysis of penicillin-G(Pc-G) and plotted calibration curve correlating potential to concentration of Pc-G linearly. The optimal concentration of buffer solution was theoretically calculated and was also experimented. We tried to explain the linear curve of potential to concentration of Pc-G by using Henderson-Hasselbach equation. This method is more effective in calibration curve plotting than any other previous methods. The results obtained may help in further developing pH electrodes with improved analytical preformance.

  • PDF

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

Silicone Rubber Blended with Polyurethane as the Matrix for Ion-Selective Membrane Electrodes

  • Lee, Hyun Jung;Rho, Kyung Lae;Kim, Chang Yong;Oh, Bong Kyun;Cha, Geun Sig;Nam, Hakhyun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.623-630
    • /
    • 1995
  • Silicone rubber-based sodium-selective membranes are developed for solid-state ion sensors. It was shown that the potetiometric performance of SR-based membranes are greatly dependent on the type of neutral carriers employed; among the three ionophores, N,N,N',N'-tetracyclohexyl-1,2-phenylenedioxydiacetamide (ETH 2120), bis[(12-crown-4)methyl]dodecylmethylmalonate (D12C4DMM) and monensin methyl ester (MME), examined, only ETH 2120 was compatible with the SR-based matrix. Addition of about 20 wt% plasticizer to the SR-based matrix provided the resulting membranes with potentiometric properties essentially equivalent to those of the corresponding PVC-based membranes. Owing to the strong adhesive strength of SR-based membranes, the CWEs coated \vith those membranes exhibited long lifetime with conventional electrode-like performance. Blending of PU into the SR matrix increased the lifetime of CWEs from two weeks to one month.

  • PDF

Syntheses and Potentiometric Properties of Polyethers Containing Thiazole and Oxazole Derivatives

  • 최준혁;고영국;권일전;김홍석;박현주;김상진;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권5호
    • /
    • pp.581-586
    • /
    • 1999
  • A series of polyethers containing the thiazole or oxazole subcyclic moiety have been synthesized. Reaction of 2-aryl-4-hydroxymethylthiazole with tetra- and pentaethylene glycol di-p-tosylate in THF provided corresponding α,ω-bis[2'-aryl-4'-methylthiazole]polyethylene glycol in good yields. Similar treatment of 2-phenyl-4-hydroxymethyloxazole 7 and 2-phenyl-5-hydroxymethyloxazole 8 with tetraethylene glycol di-p-tosylate yielded the corresponding 1,13-bis [2'-phenyl-4'-methyloxazole]tetraethylene glycol 16 and 1,13-bis[2'-phenyl-5'-methyloxazole]tetraethylene glycol 17 in 69 and 43% yields in respectively. The potentiometric properties of PVC-based ion selective membranes containing 66 wt% o-nitrophenyloctyl ether (NPOE) and 4 wt% polyethers 9-17 have been examined. The membranes containing thiazole and oxazole polyether derivatives exhibited high selectivity toward silver (I) ion. It was observed that the response slopes of the electrodes to silver ion vary with the length of polyether chain linking two thiazole subcyclic moiety. Potentiometric data suggest that the number of ether units, CH2OCH2, for phenylthiazole derivatives be greater than 5 to result in near-Nernstian response. However, the response behaviors of the membrane electrodes based on phenyloxazole podands 16 and 17, which have different orientation, were correspondingly similar to those of the electrodes based on phenylthiazole podands 9 and 10. On the other hand, the ISEs based on thiazole polyether derivatives with different terminal substituents, e.g., phenyl 10, naphtyl 14, and thienyl 15, except that with pyridyl 12, exhibited little difference in their potentiometric properties.

Sorption of Pb and Cu on different types of microplastics

  • Ruri, Lee;Eun Hea, Jho;Jinsung, An
    • Membrane and Water Treatment
    • /
    • 제14권1호
    • /
    • pp.19-25
    • /
    • 2023
  • The studies on the effect of different plastic properties (e.g., types, shapes, presence of additivies) on the sorption of contaminants in the agricultural environment are limited. In this study, Cu and Pb, the commonly found heavy metals in the environment, were used to investigate the sorption capacities of microplastics (MPs). The Pb sorption capacity increased in the order of polystyrene (PS)<polyethylene (PE)<polyvinyl chloride (PVC). The estimated Cu sorption capacity was greater for the PE films than the PE fragments, while the sorption strength was greater for the PE fragments. This suggests that the shapes of MPs can affect the contaminant sorption capacities. With the PE fragments, the Pb sorption capacity was greater than the Cu sorption capacity by 10-12 times. Also, the Pb and Cu sorption capacities were greater for the PE fragments with additives than the PE fragment without additives. After the sorption of Pb or Cu on MPs, the toxic effects of the Pb or Cu solutions were decreased, suggesting that the toxic effects of contaminants can be affected by the co-presence of MPs in the environment. Overall, the results show that different types and shapes of MPs and the presence of additives can affect the heavy metal sorption capacities of MPs.

용해기체 분석용 기체감응막 이온선택성 전극 (제 4 보) 관형 PVC막 pH전극을 이용한 황화이온의 연속 · 자동화 정량 (Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (Ⅳ). Continuous-Automated Determination of Sulfide Ion Using Tubular PVC Membrane Type pH Electrode)

  • 이흥락;배준웅;오상협
    • 대한화학회지
    • /
    • 제36권5호
    • /
    • pp.638-643
    • /
    • 1992
  • 황화이온검출기로서 2가지 형태의 연속 flow-through 전극계의 분석적 감응성질을 조사하고, 최적조건에서 그들의 감응특성을 직접 비교하였다. 두 검출계에 있어서 측정한 봉우리전위를 황화이온농도의 대수값과 관련지웠으며, 적어도 시간당 20개의 시료를 정량할 수 있었다. pH전극법에서는 투석기를 지나 흘러가는 recipient stream의 pH를 측정하였다. 장치는 연속흐름형의 기체투석기가 관형 polymer 막전극과 연결되도록 설계되어 있다. 이 방법의 최적실험조건은 recipient $5.0 {\times} 10^{-5} M NaOH + 5.0 {\times} 10^{-3} M$ NaCl과 diluent 0.10M $H_2SO_4$이며, recipient stream, diluent stream 및 시료의 유속은 모두 1.0ml/min이다. 황화이온 전극법에서는 시판하는 황화이온선택성 전극을 flow-through cell 속의 황화이온을 검출하는 데에 썼다. 이 방법의 최적실험조건인 황화이온 산화방지 완충제(1.0M NaOH 용액에 3.5g 아스코르브산과 7.6g $Na_2EDTA$를 용해)와 시료의 유속은 각각 1.4 ml/min와 1.0 ml/min이다.

  • PDF

이온선택성 멤브레인을 이용한 양액 내 질산태 질소 및 칼륨 측정 (Sensing NO3-N and K Ions in Hydroponic Solution Using Ion-Selective Membranes)

  • 김원경;박두산;김영주;노미영;조성인;김학진
    • Journal of Biosystems Engineering
    • /
    • 제35권5호
    • /
    • pp.343-349
    • /
    • 2010
  • Rapid on-site sensing of nitrate-nitrogen and potassium ions in hydroponic solution would increase the efficiency of nutrient use for greenhouse crops cultivated in closed hydroponic systems while reducing the potential for environmental pollution in water and soil. Ion-selective electrodes (ISEs) are a promising approach because of their small size, rapid response, and the ability to directly measure the analyte. The capabilities of the ISEs for sensing nitrate and potassium in hydroponic solution can be affected by the presence of other ions such as calcium, magnesium, sulfate, sodium, and chloride in the solution itself. This study was conducted to investigate the applicability of two ISEs consisting of TDDA-NPOE and valinomycin-DOS PVC membranes for quantitative determinations of $NO_3$-N and K in hydroponic solution. Nine hydroponic solutions were prepared by diluting highly concentrated paprika hydroponic solution to provide a concentration range of 3 to 400 mg/L for $NO_3$-N and K. Two of the calibration curves relating membrane response and nutrient concentration provided coefficients of determination ($R^2$) > 0.98 and standard errors of calibration (SEC) of < 3.79 mV. The use of the direct potentiometry method, in conjunction with an one-point EMF compensation technique, was feasible for measuring $NO_3$-N and K in paprika hydroponic solution due to almost 1:1 relationships and high coefficients of determination ($R^2$ > 0.97) between the levels of $NO_3$-N and K obtained with the ion-selective electrodes and standard instruments. However, even though there were strong linear relationships ($R^2$ > 0.94) between the $NO_3$-N and K concentrations determined by the Gran's plot-based multiple standard addition method and by standard instruments, hydroponic $NO_3$-N concentrations measured with the ISEs, on average, were about 10% higher than those obtained with the automated analyzer whereas the K ISE predicted about 59% lower K than did the ICP spectrometer, probably due to no compensation for a difference between actual and expected concentrations of standard solutions directly prepared.