• 제목/요약/키워드: PV Cells

검색결과 260건 처리시간 0.034초

공기 중의 미세먼지에 의한 태양전지의 오염에 관한 연구 (A Study on the Contamination of Photovoltaic Cells by Fine Dust in the Air)

  • 한진목;최수광;김세웅;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권3호
    • /
    • pp.292-298
    • /
    • 2018
  • The contamination of photovoltaic (PV) cells reduces the incidence of sunlight and reduces the power generation output of PV cells. The main factor influencing the contamination of PV cells installed outdoors is the fine dust in the air, but the influence of temperature, humidity, rain and wind can be considered. In this paper, experiments on the contamination of PV cells according to the fine dust density, the temperature and humidity of air were investigated. As results of this study, the contamination area of PV cells increases with contamination time and cumulative fine dust density in the air. The contamination of PV cells increases when the temperature is low and the humidity is high. Also, as the contamination of PV cells is affected to the wind, the deviation of contamination area is happened.

PV moudule의 출력손실 저감요인 분석 (A Study for reduction of the power loss of PV modules)

  • 이상훈;강기환;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.45-50
    • /
    • 2011
  • The efficiency of solar cell was about 4[%] in initial stage of photovoltaic industry, but it has quite a lot of efficiency through technology advances. Today, the efficiency of c-Si solar cells is about 17 to 19[%] and the efficiency of PV modules is about 14 to 15 [%]. We called that electrical losses occurred in the Conversion of solar cells to PV modules are CTM loss(Cell To Module loss), the CTM loss typically has a value of about3~5[%]. The more efficiency of solar cell increase, differences are larger because the efficiency decrease owing to physical or technical problems occurred in the Conversion of solar cells to PV modules. In this study, the power loss factors occurred in the Conversion of solar cells to PV modules are analyzed and it is proposed that how to reduce losses of the PV module. The types of power loss factor are (1)losses of front glass and encapsulant(generally EVA sheet), (2)losses by sorting miss, (3)losses by interconnection, (4)losses by the field aging of PV modules. In further study, experimental and evaluation will be conducted to make demonstrate for proposed solutions.

  • PDF

PV모듈에서 후면Sheet의 광학적 특성에 따른 전기적 출력 특성 (Electrical Characteristics of PV Module According to Optical Characteristics of Back-sheet)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.42-47
    • /
    • 2008
  • In this paper, we analyze the electrical characteristics of PV depending on distance among solar cells before and after lamination process. From the result, the PV module's maximum power increases about 3.37% when solar cells's distance is 10mm. And the maximum power increases up to 8.42% when solar cells's maximum distance is 50mm. It is assumed that PV module's surface temperature decreases because of increasing distance between solar cells that would give high power generation. Also, short distance between solar cell and frame result in contamination on glass. When considering reduced maximum power caused by contaminant, from that. we can fabricated PV module of lower cost with high performance.

  • PDF

주변온도와 일사량을 고려한 PV Cell의 전기적 특성 분석 (Analysis on Electrical Characteristics of PV Cells considering Ambient Temperature and Irradiance Level)

  • 박현아;김효성
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.481-485
    • /
    • 2016
  • When analyzing economic feasibility for installing a PV generation plant at a certain location, the prediction of possible annual power production at the site using the target PV panels should be conducted on the basis of the local weather data provided by a local weather forecasting office. In addition, the prediction of PV generating power under certain weather conditions is useful for fault diagnosis and performance evaluation of PV generation plants during actual operation. This study analyzes PV cell characteristics according to a variety of weather conditions, including ambient temperature and irradiance level. From the analysis and simulation results, this work establishes a proper model that can predict the output characteristics of PV cells under changes in weather conditions.

커튼 월에 적용하는 플랙시블 태양전지의 모양에 따른 성능 비교 (Comparison of Performance of Flexible Solar Cells construction applied to Curtain Walls)

  • 김재진
    • 디지털산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.163-168
    • /
    • 2018
  • In this paper presents comparison of performance of flexible solar cells construction applied to curtain walls. The proposed paper compares power generation for curtain walls of various shapes using flexible PV. Through the comparison of performance, the power generation was compared by installing various types of flexible PV on the air layer of double windows. By comparing the measured power generation, it is possible to find an optimal flexible PV shape that can be applied to a curtain wall. Flexible PV installation was divided into diagonal, S and W shapes. As a result of comparison, the amount of power generation when there was no flexure of flexible PV was large. Also, as the angle with the light source increased, the power generation decreased. Therefore, it is necessary to study the structure which can fix the PV more than the flexible PV and to be able to direct the sun without distortion.

태양광 발전의 효율 향상을 위한 자동추적 제어 알고리즘 개발 (Development of Automatic Tracking Control Algorithm for Efficiency Improvement of PV Generation)

  • 최정식;고재섭;정동화
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1823-1831
    • /
    • 2010
  • This paper proposes an automatic tracking control algorithm for efficiency improvement of photovoltaic generation. Increasing the power of PV systems should improve the efficiency of solar cells or the power condition system. The normal alignment of the PV module always have to run perpendicular to the sun's rays. The solar tracking system, able to improve the efficiency of the PV system, was initiated by applying that to the PV power plant. The tracking system of conventional PV power plant has been studied with regard to the tracking accuracy of the solar cells. Power generation efficiency were increased by aligning the cells for maximum exposure to the sun's rays. Using a perpendicular position facilitated optimum condition. However, there is a problem about the reliability of tracking systems unable to not track the sun correctly during environmental variations. Therefore, a novel control algorithm needs to improve the generation efficiency of the PV systems and reduce the loss of generation. This control algorithm is the proposed automatic tracking algorithm in this paper. Automatic tracking control is combined the sensor and program method for robust control in environment changing condition. This tracking system includes the insolation, rain sensor and anemometer for climate environment changing. Proposed algorithm in this paper, is compared to performance of conventional tracking control algorithm in variative insolation condition. And prove the validity of proposed algorithm through the experimental data.

Characteristics variation of PV module by damaged bypass diodes

  • 신우균;정태희;고석환;강기환;장효식
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.424.2-424.2
    • /
    • 2016
  • Solar cell converts light energy to electric energy. But a solar cell generates low power, PV module is fabricated by connected in series with dozens of solar cell. Owing to solar cell connected in series, power of PV module is influenced by shading or mismatch power of solar cells. To prevent power loss of PV module by shading or mismatch current, Bypass diodes are installed in PV module. Bypass diode operating reverse voltage by shading or mismatch power of solar cells bypass mismatch current. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we confirm characteristics variation of PV module with damaged bypass diode. As a result, power of PV module with damaged bypass diode is reduced and Temperature of that is increased.

  • PDF

PV모듈에서 태양전지의 간격에 따른 전기적 출력 특성 분석 (The Analysis of maximum output power of PV module by solar cell Interval)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.13-14
    • /
    • 2008
  • In this paper, we analyze the electrical characteristics of PV depending on distance among solar cells before and after lamination process. From the result, the PV module's maximum power increases about 3.37% when solar cells's distance is 10mm. And the maximum power increases up to 8.42% when solar cells's maximum distance is 50mm. It is assumed that PV module's surface temperature decreases because of increasing distance between solar cells that would give high power generation. Also, short distance between solar cell and frame result in contamination on glass. When considering reduced maximum power caused by contaminant, from that, we can fabricated PV module of lower cost with high performance.

  • PDF

Polyvinyl에 고정화된 Anabaena azollae에서의 수소생성 (Hydrogen Production in Polyvinyl-Immobilized Anabaena azollae Cells)

  • 박인호;송종호
    • KSBB Journal
    • /
    • 제6권2호
    • /
    • pp.181-187
    • /
    • 1991
  • 본 연구에서는 PV에 아나베나세포를 흡착법에 의하여 고정화하였다. 진탕배양하면서 고정화한 겨웅에 비하여 반응기속에 배양액을 trickling 시키면서 배양하고 고정한 경우 높은 세포밀도를 보였다. PV에 고정화한 세포들의 생리적 활성을 조사한 결과 광합성능이 암처보관시에 free cell에 비하여 안정됨을 보였고, msx처리시의 암모니아의 방출도 증가하였다. 뿐만 아니라 고정화한 세포에서 광합성활성의 온도에 대한 내성이 증가하였으며 nitrogenase 효소 활성도 free cell에 비하여 크게 증가하였다. nitrogenase효소에 의한 연속적인 광수소발생을 조사한 결과 혐기적 조건하에서 연속적으로 수소가 생성됨을 볼 수 있었는데 그 발생양은 4mg의 엽록소에 해당하는 아나베나를 충진한 trickling-medium 반응기에서 6일동안 1.6ml의수소가 생성되었다.

  • PDF