• 제목/요약/키워드: PV창호시스템

검색결과 10건 처리시간 0.033초

공동주택 벽체 반사율에 따른 PV창호시스템 발전효율 분석 (Analysis of Generating Efficiency in PV Window System consequent on Apartment House Wall Reflectivity)

  • 최두성;안준호;전흥찬;도진석
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.31-39
    • /
    • 2016
  • This study did quantitative comparative evaluation of changes in generation consequent on reflectivity of the protruding wall near the widow in case of application of PV window system to an apartment house. To be concrete, this study did comparative analysis of the generation of (B) through the process of composing Mock-up (A)comprising the protruding window near the window and Mock-up(B) free of nearby wall interference, and giving change to the reflectivity of the wall (Case_1~3). The analysis result showed that the difference in generation was slight in case solar radiation was less than 10,000Wh in all three conditions. On the contrary, in case solar radiation was more than 10,000 Wh, the generation as against Module(B), was analyzed to be 87~91% in Case_1(5% reflectivity), 18~60% in Case_2(85% reflectivity), and 16~71% in case_3(93% reflectivity), respectively.

투과율에 따른 비정질실리콘 BIPV 시스템 효율 평가 (Performance Evaluation of a-Si BIPV System According to Transmittance Variation)

  • 차광석;이병두;김강석;신승철;이대우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.60.1-60.1
    • /
    • 2010
  • 공동주택에서 태양광발전(PV)을 통한 세대 전기에너지 이용은 모듈 설치 면적의 제약으로 인해 전 세대를 대상으로 활용하기에 현실적으로 어려움이 있다. 특히 남향이나 남동, 남서향으로 위치한 거실 창호를 활용하는 경우에도 결정질 실리콘(crystalline silicon) 태양전지 셀로 인한 실내 음영문제 등으로 건물통합형 태양광발전(BIPV) 시스템의 가시성을 확보하는데 한계가 있다. 따라서 이런 문제점을 극복하고자 투광형 비정질실리콘(amorphous silicon) 태양전지를 이용한 발코니창호/커튼월 BIPV 시스템을 구축하고, 테스트베드를 통한 적용성 평가 검증을 수행하였다. 테스트베드는 KCC 중앙연구소 1층 외부 측창에 결정질 BIPV 모듈(A2PEAK 사(社), 최대 출력 210 Wp, W 2,000 mm ${\times}$ H 1,066 mm)과 10% 및 30% 투광형 비정질 BIPV 모듈(Sharp 사(社) See Through type, 최대 출력 135 Wp/123 Wp, W 1,930 mm ${\times}$ H 1,180 mm)을 각각 설치(남서 $30^{\circ}$, 수직 $90^{\circ}$)하여, 2009년 5월에서 8월 사이 4개월에 걸친 모니터링을 통해 실제 발전량 데이터를 확보, 시스템에 대한 분석을 진행하였다. 분석 결과, 설치용량당 일평균 발전량은 결정질형이 1.46 kWh/kWp, 10% 투광형은 1.10 kWh/kWp, 30% 투광형은 0.73 kWh/kWp을 나타내었다. 10% 투광형과 30% 투광형의 모듈 성능 차이는 크지 않으나 발전량에 있어서는 큰 차이를 보였고, 10% 투광형의 설치용량당 일평균 발전량은 경정질형의 75.2% 수준으로 투광형 비정질실리콘 BIPV 시스템의 창호 적용 가능성을 확인하였다. 특히 세대 거실 창호를 통한 가시성 확보는 기존 결정질 BIPV 창호의 단점을 개선하였다. 건자재 일체화로 구축된 가시성확보 BIPV시스템 창호는 단위 세대별 적용이 쉽고, 공동주택에서 PV 시스템의 설치면적을 극대화시키므로 향후 Zero Energy 공동주택 구축에도 활용성이 클 것으로 기대된다.

  • PDF

PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구 (A Study on the Performance of Blind type Double-Skin Facade System with PV modules)

  • 조혜진;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

일사량 확률분포함수를 이용한 태양광 발전시스템 발전량 예측 (Photovoltaic Generation System Output Forecasting using Irradiance Probability Distribution Function)

  • 이일룡;배인수;정창호;김진오;심헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.548-550
    • /
    • 2004
  • This paper suggests a methodology for calculation of photovoltaic(PV) generation system output using probability distribution function, PV way efficiency and PV system design Parameters. Long term irradiance recorded for every hour of the day for 11 years were used. For goodness-fit test, several distribution functions are tested by Kolmogorov- Smirnov(K-S) test. And the calculated generation output is compared with that of CMS(Centered Monitoring System), which can monitoring PV generation output of each PV generation site.

  • PDF

냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구 (A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load)

  • 안형준;김영탁;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구 (Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level)

  • 윤종호;오명환;강기환;이재범
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

RPS 제도 하에서의 태양광발전 연계형 배터리시스템 수익분석 방법에 관한 연구 (The Profitability Analysis of BESS Installation with PV Generation under RPS)

  • 김창수;유태현;이창호
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.107-117
    • /
    • 2017
  • 2012년 Renewable Portfolio Standard(RPS) 제도가 시행된 이래, 태양광 및 풍력 등의 신재생 전원에 대한 대규모 투자가 이루어져 왔고, 최근에 정부는 배터리 에너지 저장시스템(Battery Energy Storage System, BESS)의 신재생설비 연계설치에 대한 정책을 도입하여 신재생설비가 전원으로서의 역할이 가능하게끔 유도하고 있다. 정책입안자 입장에서 변화하는 전력산업 환경을 수급관점에서 고려하기 위해서는 개별 정책효과 분석을 단순화하는 방법론을 필요로 한다. 이에 본 연구에서는 초기단계로 시작한 태양광발전 연계형 배터리시스템 정책 분석을 위해 국내 태양광 발전 실적을 바탕으로 태양광 발전량 분포를 일간이용률 지속곡선 형태로 제안하였고, 이를 바탕으로 최적 BESS 용량을 산출하는 방식을 통해 분석의 용이성을 향상시킬 수 있도록 하였다. 본 논문의 방식을 통해 System Marginal Price(SMP) 및 REC 변화에 따른 BESS의 적정용량 범위를 간단히 파악할 수 있으며, 신재생정책 입안자 입장에서 정책효과를 가늠할 수 있도록 하는 도구로 이용할 수 있다. 현행 연계형 BESS 지원정책은 투자유인 제공이 부분적으로 가능하나, 설치 시점의 SMP 및 REC 가격에 영향을 받게 된다는 한계가 있다. REC 가격 상승과 감소에 따라서 시기별 최적용량이 바뀌어 설치비율이 계속 달라질 수 있어 정책변화에 의해 기술의 적용이 달라지는 결과를 가져온다. 따라서, 향후 제도개선을 모색할 경우에는 연계형 BESS 가치평가시, 신재생전원과의 BESS의 발전량 분할로 인해 발생하는 정책지원에 대한 기술 의존성을 해결할 수 있는 방안을 고려하는 연구개발이 필요하다.

염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구 (A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance)

  • 오명환;심세라;이철성;진경일;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

ERP 시스템을 이용한 프로젝트 EVMS에 관한 연구 (A Study on Earned Value Management System (EVMS) For Project Using ERP System)

  • 박제원;이창호
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.145-151
    • /
    • 2010
  • It seems that a primary concern of the project-based company, which provides a large scale product or service over long term period, is to run a successful project through systematic project process control and control costs. One of the typical project control methods is Earned Value Management System(EVMS) which analyses the precess through performance measurement. Even though the EVMS is a highly efficient tool in the managerial aspect, it cannot easily determine the Planned Value(PV), Actual Cost(AC), or Earned Value(EV) due to the indistinct criteria and extensive data. The accurate calculation of AC in particular, is the basic of project management, but most companies record direct personnel expenses or direct expenses only. Since they calculate indirect expenses based on the estimated ratio, it limits the systematic project management that reflects changes in profit and loss of a company. This study introduces a EVMS for project management and its actual case based on EVMS and ERP system which some additional modules are installed for performance measurement. It is expected that this new method enables a company to save time and effort, and also to improve transparency by specifying expense items in detail and to switch quarterly settlement to monthly by reducing the time of calculation.

제로 에너지 건축물을 위한 자립형 저전력 IoT 센서 모듈 개발에 대한 연구 (A Study on Development of Independent Low Power IoT Sensor Module for Zero Energy Buildings)

  • 강자윤;조영찬;김희준
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.273-281
    • /
    • 2019
  • 국가 총에너지 소비량 중 건축물에서 소비하는 에너지는 전체의 10% 이상을 차지고 있다. 이러한 이유로 우리나라는 2025년부터 제로에너지 건물 의무화 정책을 채택하였고, 결국 건축물 에너지 절감 기술에 대한 연구가 요구되고 있다. 건축물 중 빌딩의 에너지 소비 형태를 분석해보면 조명 및 냉난방 에너지가 전체 에너지 소비량의 60% 이상을 차지하고 있는데, 이는 태양광 취득률 및 창문의 개폐 운용과 직접적인 연관이 있다. 본 논문에서는 건축물에너지 관리시스템에 취득 정보를 전송하기 위한 창호용 저전력 IoT 센서 모듈을 개발하기 위해 연구를 진행하였다. 이 모듈은 외부 환경 및 창문 개폐 상태 정보를 실시간으로 빌딩 에너지 관리 시스템에 전송하여 능동적으로 에너지 절감 조치를 취할 수 있게 네트워크를 구성하였다. 모듈에 사용되는 전력은 하베스트 에너지 중 태양광 발전을 이용한 독립적인 전원으로 설계하였다. 전원은 Buck 컨버터를 적용하여 MPPT 제어를 통해 리튬이온 배터리에 4V로 충전하는 방식으로 효율은 약 85.87%이다. 통신은 WiFi 방식을 적용하여 실시간으로 전송할 수 있도록 구성하였다. 모듈의 소비전력 저감을 위해 하드웨어 및 소프트웨어 측면에서 분석하여 저전력 IoT 센서 모듈을 구현에 대한 연구를 진행하였다.