• Title/Summary/Keyword: PV창호시스템

Search Result 10, Processing Time 0.027 seconds

Analysis of Generating Efficiency in PV Window System consequent on Apartment House Wall Reflectivity (공동주택 벽체 반사율에 따른 PV창호시스템 발전효율 분석)

  • Choi, Doo-Sung;An, Jun-Ho;Jeon, Hung-Chan;Do, Jin-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • This study did quantitative comparative evaluation of changes in generation consequent on reflectivity of the protruding wall near the widow in case of application of PV window system to an apartment house. To be concrete, this study did comparative analysis of the generation of (B) through the process of composing Mock-up (A)comprising the protruding window near the window and Mock-up(B) free of nearby wall interference, and giving change to the reflectivity of the wall (Case_1~3). The analysis result showed that the difference in generation was slight in case solar radiation was less than 10,000Wh in all three conditions. On the contrary, in case solar radiation was more than 10,000 Wh, the generation as against Module(B), was analyzed to be 87~91% in Case_1(5% reflectivity), 18~60% in Case_2(85% reflectivity), and 16~71% in case_3(93% reflectivity), respectively.

Performance Evaluation of a-Si BIPV System According to Transmittance Variation (투과율에 따른 비정질실리콘 BIPV 시스템 효율 평가)

  • Cha, Kwangseok;Lee, Byoungdoo;Kim, Kangsuk;Shin, Seungchul;Lee, Daewoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.60.1-60.1
    • /
    • 2010
  • 공동주택에서 태양광발전(PV)을 통한 세대 전기에너지 이용은 모듈 설치 면적의 제약으로 인해 전 세대를 대상으로 활용하기에 현실적으로 어려움이 있다. 특히 남향이나 남동, 남서향으로 위치한 거실 창호를 활용하는 경우에도 결정질 실리콘(crystalline silicon) 태양전지 셀로 인한 실내 음영문제 등으로 건물통합형 태양광발전(BIPV) 시스템의 가시성을 확보하는데 한계가 있다. 따라서 이런 문제점을 극복하고자 투광형 비정질실리콘(amorphous silicon) 태양전지를 이용한 발코니창호/커튼월 BIPV 시스템을 구축하고, 테스트베드를 통한 적용성 평가 검증을 수행하였다. 테스트베드는 KCC 중앙연구소 1층 외부 측창에 결정질 BIPV 모듈(A2PEAK 사(社), 최대 출력 210 Wp, W 2,000 mm ${\times}$ H 1,066 mm)과 10% 및 30% 투광형 비정질 BIPV 모듈(Sharp 사(社) See Through type, 최대 출력 135 Wp/123 Wp, W 1,930 mm ${\times}$ H 1,180 mm)을 각각 설치(남서 $30^{\circ}$, 수직 $90^{\circ}$)하여, 2009년 5월에서 8월 사이 4개월에 걸친 모니터링을 통해 실제 발전량 데이터를 확보, 시스템에 대한 분석을 진행하였다. 분석 결과, 설치용량당 일평균 발전량은 결정질형이 1.46 kWh/kWp, 10% 투광형은 1.10 kWh/kWp, 30% 투광형은 0.73 kWh/kWp을 나타내었다. 10% 투광형과 30% 투광형의 모듈 성능 차이는 크지 않으나 발전량에 있어서는 큰 차이를 보였고, 10% 투광형의 설치용량당 일평균 발전량은 경정질형의 75.2% 수준으로 투광형 비정질실리콘 BIPV 시스템의 창호 적용 가능성을 확인하였다. 특히 세대 거실 창호를 통한 가시성 확보는 기존 결정질 BIPV 창호의 단점을 개선하였다. 건자재 일체화로 구축된 가시성확보 BIPV시스템 창호는 단위 세대별 적용이 쉽고, 공동주택에서 PV 시스템의 설치면적을 극대화시키므로 향후 Zero Energy 공동주택 구축에도 활용성이 클 것으로 기대된다.

  • PDF

A Study on the Performance of Blind type Double-Skin Facade System with PV modules (PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구)

  • Jo, Hye-Jin;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

Photovoltaic Generation System Output Forecasting using Irradiance Probability Distribution Function (일사량 확률분포함수를 이용한 태양광 발전시스템 발전량 예측)

  • Lee Il Ryong;Bae In Su;Jung Chang Ho;Kim Jln O;Shim Hun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.548-550
    • /
    • 2004
  • This paper suggests a methodology for calculation of photovoltaic(PV) generation system output using probability distribution function, PV way efficiency and PV system design Parameters. Long term irradiance recorded for every hour of the day for 11 years were used. For goodness-fit test, several distribution functions are tested by Kolmogorov- Smirnov(K-S) test. And the calculated generation output is compared with that of CMS(Centered Monitoring System), which can monitoring PV generation output of each PV generation site.

  • PDF

A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load (냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구)

  • An, Hyung-Jun;Kim, Young-Tag;Choi, Chang-Ho;Lee, Hyn-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

The Profitability Analysis of BESS Installation with PV Generation under RPS (RPS 제도 하에서의 태양광발전 연계형 배터리시스템 수익분석 방법에 관한 연구)

  • Kim, Chang-Soo;Yoo, Tae-Hyun;Rhee, Chang-Ho
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.107-117
    • /
    • 2017
  • Since South Korea started to apply Renewable Portfolio Standard (RPS) in 2012, there have been huge investment for deploying renewable technologies. Recently, the government determined to incentivize battery energy storage system(BESS) with renewable generations in order to induce the improvement of dispatching capability. In this paper, the annual pattern of PV generation based on actual generation data in South Korea is analyzed and the duration curve of capacity factor is proposed in order to provide the simplified analyzing methodology of present support policy for additional BESS installation for decision maker who is responsible for supply and demand planning. With suggested methodology, the range of appropriate BESS size with respect to the variation of system marginal price(SMP) and renewable energy certificate(REC) price can be derived briefly, and decision makers easily evaluate the effect of support scheme. Current policy for BESS installation support present additional BESS-related installation policy may give incentives to developers partially, however, the dependence between BESS size and benefit components (SMP and REC) can limit the deployment of the various portfolios of the BESS. Therefore, when improving the current policy in future, addressing the dependence between the technical aspects of battery size and the benefit components separately by the technical and economical parts is needed to set the suitable compensation rules for the renewable generation and BESS.

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

A Study on Earned Value Management System (EVMS) For Project Using ERP System (ERP 시스템을 이용한 프로젝트 EVMS에 관한 연구)

  • Park, Je-Won;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.145-151
    • /
    • 2010
  • It seems that a primary concern of the project-based company, which provides a large scale product or service over long term period, is to run a successful project through systematic project process control and control costs. One of the typical project control methods is Earned Value Management System(EVMS) which analyses the precess through performance measurement. Even though the EVMS is a highly efficient tool in the managerial aspect, it cannot easily determine the Planned Value(PV), Actual Cost(AC), or Earned Value(EV) due to the indistinct criteria and extensive data. The accurate calculation of AC in particular, is the basic of project management, but most companies record direct personnel expenses or direct expenses only. Since they calculate indirect expenses based on the estimated ratio, it limits the systematic project management that reflects changes in profit and loss of a company. This study introduces a EVMS for project management and its actual case based on EVMS and ERP system which some additional modules are installed for performance measurement. It is expected that this new method enables a company to save time and effort, and also to improve transparency by specifying expense items in detail and to switch quarterly settlement to monthly by reducing the time of calculation.

A Study on Development of Independent Low Power IoT Sensor Module for Zero Energy Buildings (제로 에너지 건축물을 위한 자립형 저전력 IoT 센서 모듈 개발에 대한 연구)

  • Kang, Ja-Yoon;Cho, Young-Chan;Kim, Hee-Jun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.273-281
    • /
    • 2019
  • The energy consumed by buildings among the total national energy consumption is more than 10% of the total. For this reason, Korea has adopted the zero energy building policy since 2025, and research on the energy saving technology of buildings has been demanded. Analysis of buildings' energy consumption patterns shows that lighting, heating and cooling energy account for more than 60% of total energy consumption, which is directly related to solar power acquisition and window opening and closing operation. In this paper, we have developed a low - power IoT sensor module for window system to transfer acquired information to building energy management system. This module transmits the external environment and window opening / closing status information to the building energy management system in real time, and constructs the network to actively take energy saving measures. The power used in the module is designed as an independent power source using solar power among the harvest energy. The topology of the power supply is a Buck converter, which is charged at 4V to the lithium ion battery through MPPT control, and the efficiency is about 85.87%. Communication is configured to be able to transmit in real time by applying WiFi. In order to reduce the power consumption of the module, we analyzed the hardware and software aspects and implemented a low power IoT sensor module.