• Title/Summary/Keyword: PV/T system

Search Result 84, Processing Time 0.023 seconds

Renewable energy deployment policy-instruments for Cameroon: Implications on energy security, climate change mitigation and sustainable development

  • Enow-Arrey, Frankline
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.6 no.1
    • /
    • pp.56-68
    • /
    • 2020
  • Cameroon is a lower middle-income country with a population of 25.87 million inhabitants distributed over a surface area of 475,442 ㎢. Cameroon has very rich potentials in renewable energy resources such as solar energy, wind energy, small hydropower, geothermal energy and biomass. However, renewable energy constitutes less than 0.1% of energy mix of the country. The energy generation mix of Cameroon is dominated by large hydropower and thermal power. Cameroon ratified the Paris Agreement in July 2016 with an ambitious 20% greenhouse gas (GHG) emission reduction. This study attempts to investigate some renewable energy deployment policy-instruments that could enable the country enhance renewable energy deployment, gain energy independence, fulfill Nationally Determined Contribution (NDC) and achieve Sustainable Development Goals. It begins with an analysis of the status of energy sector in Cameroon. It further highlights the importance of renewable energy in mitigating climate change by decarbonizing the energy mix of the country to fulfill NDC and SDGs. Moreover, this study proposes some renewable energy deployment policy-solutions to the government. Solar energy is the most feasible renewable energy source in Cameroon. Feed-in Tariffs (FiT), is the best renewable energy support policy for Cameroon. Finally, this study concludes with some recommendations such as the necessity of building an Energy Storage System as well a renewable energy information and statistics infrastructure.

The Study on Algorithm for Partial shade Compasation of PV (태양광 발전시스템의 부분그늘 보상을 위한 알고리즘에 관한 연구)

  • Koh K. H.;Lee H. W.;Suh K. Y.;Koh H. S.;Moon S. C.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.271-274
    • /
    • 2003
  • In this paper, compare and analyze existent MPPT algorithms. Existent algorithms have defects which don't generate it in a partial shade or low insolation. Therefore, to supplement it, we design improved IncCond algorithm consisted of a Aux. switch and capacitor with Generation Control circuit which can always obtain maximum generation power at the factor which is reduced generational efficiency by partial shade. Generation Control circuit is method which can always get maximum output power as it regularly controls each voltage of serial connected solar cell. Accordingly, it can improve efficiency and confidence of utility interaction inverter. Construction of system use a low price PIC16F87X. We analyze special character according to system operation through simulation and prove the validity through experiments.

  • PDF

A Study on the Safety of the Electronic Rear Brake Pressure Reducing System using a Direct Adaptive Fuzzy Controller (직접 적응식 퍼지 제어기를 이용한 전자식 후륜 제동압력 감압 시스템 안전성에 관한 연구)

  • 김남헌;김훈모
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.157-165
    • /
    • 2001
  • In the brake systems, it is important to reduce the rear brake pressure in order to secure the safety of the vehicle in braking. So, there was some research that reduced and controlled the rear brake pressure exactly like a LSPV and a ELSPV. However, the previous research has some weaknesses: the LSPV is a mechanical system and its brake efficiency is lower than the efficiency of ELSPV, But, the cost of ELSPV is very higher so its application to the vehicle is very difficult. Additionally, when a fail appears in the circuit which controls the valves, the fail results in some wrong operation of the valves. But, the previous researchers didn't take the effect of fail into account. Hence, the efficiency of them is low and the safety of the vehicle is not confirmed. So, in this paper we develop a new economical pressure modulator that exactly controls brake pressure and confirms the safety of the vehicle in any case using a direct adaptive fuzzy controller.

  • PDF

Research on Model to Diagnose Efficiency Reduction of Inverters using Multilayer Perceptron (다층 퍼셉트론을 이용한 인버터의 효율 감소 진단 모델에 관한 연구)

  • Jeong, Ha-Young;Hong, Seok-Hoon;Jeon, Jae-Sung;Lim, Su-Chang;Kim, Jong-Chan;Park, Chul-Young
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.10
    • /
    • pp.1448-1456
    • /
    • 2022
  • This paper studies a model to diagnose efficiency reduction of inverter using Multilayer Perceptron(MLP). In this study, two inverter data which started operation at different day was used. A Multilayer Perceptron model was made to predict photovoltaic power data of the latest inverter. As a result of the model's performance test, the Mean Absolute Percentage Error(MAPE) was 4.1034. The verified model was applied to one-year-old and two-year-old data after old inverter starting operation. The predictive power of one-year-old inverter was larger than the observed power by 724.9243 on average. And two-year-old inverter's predictive value was larger than the observed power by 836.4616 on average. The prediction error of two-year-old inverter rose 111.5572 on a year. This error is 0.4% of the total capacity. It was proved that the error is meaningful difference by t-test. The error is predicted value minus actual value. Which means that PV system actually generated less than prediction. Therefore, increasing error is decreasing conversion efficiency of inverter. Finally, conversion efficiency of the inverter decreased by 0.4% over a year using this model.

Relationships between Nailfold Plexus Visibility and Clinical Variables in Adult Schizophrenics (성인 정신분열병 환자에서 손톱주름 총 시도(叢 視度) (Nailfold Plexus Visibility)와 임상 변인과의 관계)

  • Kang, Dae-Yeob;Chang, Hi-Yeoul;Kang, Sung-Suk
    • Korean Journal of Biological Psychiatry
    • /
    • v.6 no.1
    • /
    • pp.111-118
    • /
    • 1999
  • Objectives : There have been several evidences that the central nervous system defect is one of the etiologic factors in schizophrenia and high nailfold plexus visibility can reflect these defects indirectly. These are particularly related to the negative symptoms of schizophrenia. In this study, we examined the relationship between nailfold plexus visibility and various clinical variables in schizophrenia. Methods : Forty patients(20 males, 20 females) satisfying the DSM-lV criteria for schizophrenia and forty normal controls(20 males, 20 females) were measured for Plexus Visualization Score (PVS) by using capillary microscopic examination. We used Positive and Negative Syndrome Scale(PANSS), Ulmann-Giovannoni Process-Reactive Questi-onnaire(PRQ), Phillips Premorbid Adjustment Scale(PAS), Continuous Performance Test, and Backward Masking for psychopathology and clinical variables. Results : There was no significant relationship between schizophrenic subjects and normal controls in PVS. PVS was correlated with PANSS positively except negative symptom subscore. PVS was correlated with PRQ score negatively, and with PAS score positively. Conclusions : This study shows high PVS are associated with more severe psychotic symptoms and with clinical variables, such as disease process and premorbid adjustment, in some schizophrenics.

  • PDF

Bacillus oryzicola sp. nov., an Endophytic Bacterium Isolated from the Roots of Rice with Antimicrobial, Plant Growth Promoting, and Systemic Resistance Inducing Activities in Rice

  • Chung, Eu Jin;Hossain, Mohammad Tofajjal;Khan, Ajmal;Kim, Kyung Hyun;Jeon, Che Ok;Chung, Young Ryun
    • The Plant Pathology Journal
    • /
    • v.31 no.2
    • /
    • pp.152-164
    • /
    • 2015
  • Biological control of major rice diseases has been attempted in several rice-growing countries in Asia during the last few decades and its application using antagonistic bacteria has proved to be somewhat successful for controlling various fungal diseases in field trials. Two novel endophytic Bacillus species, designated strains YC7007 and $YC7010^T$, with antimicrobial, plant growth-promoting, and systemic resistance-inducing activities were isolated from the roots of rice in paddy fields at Jinju, Korea, and their multifunctional activities were analyzed. Strain YC7007 inhibited mycelial growth of major rice fungal pathogens strongly in vitro. Bacterial blight and panicle blight caused by Xanthomonas oryzae pv. oryzae (KACC 10208) and Burkholderia glumae (KACC 44022), respectively, were also suppressed effectively by drenching a bacterial suspension ($10^7cfu/ml$) of strain YC7007 on the rhizosphere of rice. Additionally, strain YC7007 promoted the growth of rice seedlings with higher germination rates and more tillers than the untreated control. The taxonomic position of the strains was also investigated. Phylogenetic analyses based on 16S rRNA gene sequences indicated that both strains belong to the genus Bacillus, with high similarity to the closely related strains, Bacillus siamensis KACC $15859^T$ (99.67%), Bacillus methylotrophicus KACC $13105^T$ (99.65%), Bacillus amyloliquefaciens subsp. plantarum KACC $17177^T$ (99.60%), and Bacillus tequilensis KACC $15944^T$ (99.45%). The DNA-DNA relatedness value between strain $YC7010^T$ and the most closely related strain, B. siamensis KACC $15859^T$ was $50.4{\pm}3.5%$, but it was $91.5{\pm}11.0%$ between two strains YC7007 and $YC7010^T$, indicating the same species. The major fatty acids of two strains were anteiso-$C_{15:0}$ and iso $C_{15:0}$. Both strains contained MK-7 as a major respiratory quinone system. The G+C contents of the genomic DNA of two strains were 50.5 mol% and 51.2 mol%, respectively. Based on these polyphasic studies, the two strains YC7007 and $YC7010^T$ represent novel species of the genus Bacillus, for which the name Bacillus oryzicola sp. nov. is proposed. The type strain is $YC7010^T$ (= KACC $18228^T$). Taken together, our findings suggest that novel endophytic Bacillus strains can be used for the biological control of rice diseases.

Constraint-corrected fracture mechanics analysis of nozzle crotch corners in pressurized water reactors

  • Kim, Jong-Sung;Seo, Jun-Min;Kang, Ju-Yeon;Jang, Youn-Young;Lee, Yun-Joo;Kim, Kyu-Wan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1726-1746
    • /
    • 2022
  • This paper presents fracture mechanics analysis results for various cracks located at pressurized water reactor pressure vessel nozzle crotch corners taking into consideration constraint effect. Technical documents such as the ASME B&PV Code, Sec.XI were reviewed and then a fracture mechanics analysis procedure was proposed for structural integrity assessment of various nozzle crotch corner cracks under normal operation conditions considering the constraint effect. Linear elastic fracture mechanics analysis was performed by conducting finite element analysis with the proposed analysis procedure. Based on the evaluation results, elastic-plastic fracture mechanics analysis taking into account the constraint effect was performed only for the axial surface crack of the reactor pressure vessel outlet nozzle with cladding. The fracture mechanics analysis result shows that only the axial surface crack in the reactor pressure vessel outlet nozzle has the stress intensity factor exceeding the low bound of upper-shelf fracture toughness irrespectively of considering the constraint effect. It is confirmed that the J-integral for the axial crack of the outlet nozzle does not exceed the ductile crack initiation toughness. Hence, it can be ensured that the structural integrity of all the cracks is maintained during the normal operation.

A study on Optimal Operation of Protection Coordination Devices Evaluation System in Distribution System with Distributed Sources (분산전원이 연계된 배전계통에 보호협조기기 평가시스템의 최적운용에 관한 연구)

  • Ji, Sungho;Song, Bangwoon;Kim, Byungki;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2971-2978
    • /
    • 2013
  • Recently, with the world-wide issues about global warming and CO2 reduction, a number of distributed generations(DGs) such as photovoltaic(PV) and wind power(WP), are interconnected with the distribution systems. However, DGs can change the direction of the power flow from one-direction to bi-direction, and also change the direction and amount of fault current of existing distribution systems. Therefore, it may cause the critical problems on the power quality and protection coordination. This paper proposes an operation algorithm for bi-directional protection coordination using and apply it for the evaluation system for protection coordination. From the simulation results It is found that the proposed method is more effective and convenient than existing method.

Fine mapping of rice bacterial leaf blight resistance loci to major Korean races of Xoo (Xanthomonas oryzae)

  • Lee, Myung-Chul;Choi, Yu-Mi;Lee, Sukyeung;Yoon, Hyemyeong;Oh, Sejong
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.10a
    • /
    • pp.73-73
    • /
    • 2018
  • Bacterial leaf blight(BLB), caused by X. oryzae pv. oryzae(Xoo), is one of the most destructive diseases of rice due to its high epidemic potential. Understanding BLB resistance at a genetic level is important to further improve the rice breeding that provides one of the best approaches to control BLB disease. In the present investigation, a collection of 192 accessions was used in the genome-wide association study (GWAS) for BLB resistance loci against four Korean races of Xoo that were represented by the prevailing BLB isolates under Xoo differential system. A total of 192 accessions of rice germplasm were selected on the basis of the bioassay using four isolated races of Xoo such as K1, K2, K3 and K3a. The selected accessions was used to prepare 384-plex genotyping by sequencing (GBS) libraries and Illumina HiSeq 2000 paired- end read was used for GBS sequencing. GWAS was conducted using T ASSEL 5.0. The T ASSEL program uses a mixed linear model (MLM). T he results of the bioassay using a selected set of 192 accessions showed that a large number of accessions (93.75%) were resistant to K1 race, while the least number of accessions (34.37%) resisted K3a race. For races K2 and K3, the resistant germplasm proportion remained between 66.67 to 70.83%. T he genotypic data produced SNP matrix for a total of 293,379 SNPs. After imputation the missing data was removed, which exhibited 34,724 SNPs for association analysis. GWAS results showed strong signals of association at a threshold of [-log10(P-value)] more than5 (K1 and K2) and more than4 (K3 and K3a) for nine of the 39 SNPs, which are plausible candidate loci of resistance genes. T hese SNP loci were positioned on rice chromosome 2, 9, and 11 for K1 and K2 races, whereas on chromosome 4, 6, 11, and 12 for K3 and K3a races. The significant loci detected have also been illustrated, NBS-LRR type disease resistance protein, SNARE domain containing protein, Histone deacetylase 19, NADP-dependent oxidoreductase, and other expressed and unknown proteins. Our results provide a better understanding of the distribution of genetic variation of BLB resistance to Korean pathogen races and breeding of resistant rice.

  • PDF

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF