• Title/Summary/Keyword: PU sheet

Search Result 16, Processing Time 0.018 seconds

Silver Nanowire-Based Stretchable Transparent Electrodes for Deformable Organic Light-Emitting Diodes (신축성 유기발광다이오드를 위한 은 나노와이어 기반의 신축성 투명 전극 기판 연구)

  • Jung, Hyunsu;Go, Hyeck;Park, Gye-Choon;Yun, Changhun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.609-614
    • /
    • 2017
  • The proposed stretchable transparent electrodes based on silver nanowires (AgNWs) were prepared on a polyurethane (PU) substrate. In order toavoid the surface roughness caused by the silver nanowires, a titanium oxide ($TiO_2$) buffer layer was addedby coating and heating the organometallic sol-gel solution. The fabricated stretchable electrodes showedan electrical sheet resistance of $24{\Omega}sq^{-1}$, 78% transmittance at 550 nm, and an average surface roughness below 5 nm. Furthermore, the AgNW-based electrode maintained its initial electrical resistance under 130% strain testing conditions, without the assistance of additional conductive polymer layers. In this paper, the critical role of the $TiO_2$ buffer layer between the AgNW network and the PU substrate has been discussed.

Recycling of Sound Insulation Headliner Waste Material (흡음재 폐기물의 재활용 방안)

  • Hong, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.3089-3095
    • /
    • 2013
  • The headliner was made of polyurethane(PU) and glass fiber(GF) composite materials are widely used as a sound insulation material. A large amount of waste materials occurs as a by-product in the headliner manufacturing process. In order to efficiently reuse the headliner waste materials, separation process of the components are very necessary. According to the results of thermal analysis, weight loss showed increase in the order polyurethane foam> non-foaming polyurethane> non-woven fabric> 1st layer> glass fiber in the range of up to $400^{\circ}C$. Analysis of the DSC characteristics, HDPE, LLDPE, PP, and Master Batch by adding additives the wasted scrap. As a result, except for the PP, there was no exothermic transition due to the crystallization.

Development of U-shaped Arterialvenous Shunt Using Porous Polyurethane (다공성 폴리우레탄을 이용한 동정맥 누관의 개발)

  • 정재승;김희찬;박광석;최진욱;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.221-230
    • /
    • 1999
  • A new technique for the preparation of porous polyurethane vascular prostheses was investigated. Synthetic vascular grafts with porous wall have been widely proposed, claiming that strength, suture retention, kink resistance, and other handling properties are improved over those with nonporous solid wall. Related to these facts, the control of pores and compliance match have been very important and interesting issues. Two kinds of polymer sheets were compared. One was the porous PU-sheet made at room temerature by the solvent/non-solvent exchange. And the other was the porous PU-sheet fabricated by thermal phase transition and solvent/non-solvent exchange in the thermal controlled bath. According to the result of the above experiments, polyurethane solution was injected into a mold designed for U-type graft. After freezing at low temperature, solvent was dissolved out with alcohol at < $0^{\circ}C$ and water at room temperature to form porous vessels. The average pore size and pore occupation were easily changed by changing polyurethane concentration and freezing rate. This technique can give a proper pore size for tissue ingrowth, and suitable compliances for matching with arteries and veins. In addition, the fabrication of more complicated shaped vessels such as the U-type vascular grafts is easily controlled by using a mold. This method might give a desired compliact graft for artificial implantaion with the commercially available medical polymers.

  • PDF

Synthesis and Characterization of Artificial Skin based on Polypeptides (Polypeptide계 인공 피부의 합성과 특성)

  • Kim, Seon-Jeong;Min, Dong-Seon;Kim, Gye-Yong
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.87-92
    • /
    • 1987
  • In order to evaluate the artificial skin for burn would covering materials, copoly(N. carbobenzoxy-L-Iysine-L-leucine)s were prepared by Ipolymerization of N - carbobenzoxy-L- I sine anhydride and L-leucine anhydride in homogeneous solvents using triethylamine as an initiator. The synthetic polypeptides and the oxter type polyurethane(PV)of medical grade were used as the sheet type membranes were prepared ; monolayer membrances were composed of only the polypeptides, bilayer membranes and blend membranes were controlled by composition of the polypeptides and PU. Test of the swelling degree, mechanical tensile strength, elongation, oxygen permeability, water-vapor loss and In vitro degradation treated by pretense TV of samples of artificial skin were measured by adequate methods so as to mechanical, physincal characterization and biodegradation. As a result, all the values of samples were found to be similar to desired value of skin which was nature. The Artificial skin based on polypeptides can be considered as ideal burn wound covering materials.

  • PDF

Energy absorption of foam-filled lattice composite cylinders under lateral compressive loading

  • Chen, Jiye;Zhuang, Yong;Fang, Hai;Liu, Weiqing;Zhu, Lu;Fan, Ziyan
    • Steel and Composite Structures
    • /
    • v.31 no.2
    • /
    • pp.133-148
    • /
    • 2019
  • This paper reports on the energy absorption characteristics of a lattice-web reinforced composite sandwich cylinder (LRCSC) which is composed of glass fiber reinforced polymer (GFRP) face sheets, GFRP lattice webs, polyurethane (PU) foam and ceramsite filler. Quasi-static compression experiments on the LRCSC manufactured by a vacuum assisted resin infusion process (VARIP) were performed to demonstrate the feasibility of the proposed cylinders. Compared with the cylinders without lattice webs, a maximum increase in the ultimate elastic load of the lattice-web reinforced cylinders of approximately 928% can be obtained. Moreover, due to the use of ceramsite filler, the energy absorption was increased by 662%. Several numerical simulations using ANSYS/LS-DYNA were conducted to parametrically investigate the effects of the number of longitudinal lattice webs, the number of transverse lattice webs, and the thickness of the transverse lattice web and GFRP face sheet. The effectiveness and feasibility of the numerical model were verified by a series of experimental results. The numerical results demonstrated that a larger number of thicker transverse lattice webs can significantly enhance the ultimate elastic load and initial stiffness. Moreover, the ultimate elastic load and initial stiffness were hardly affected by the number of longitudinal lattice webs.

A Study on Medical Laws and External Evaluation Criteria with Reference to the Essential Forms consisting Medical Records and to the Items for Each Medical Record (의료기관 종별 의무기록 중요서식 항목별 작성 실태 및 의무기록 완결점검표 분석)

  • Seo, Sun Won;Kim, Kwang Hwan;Hwang, Yong-Hwa;Kang, Sunny;Kang, Jin Kyung;Cho, Woo Hyun;Hong, Joon Hyun;Pu, Yoo Kyung;Rhee, Hyun Sill
    • Quality Improvement in Health Care
    • /
    • v.9 no.2
    • /
    • pp.176-197
    • /
    • 2002
  • Backgound : This study is to suggest the standardized format of the clinical sheets and the standardized items of every clinical sheet. The standardization of the medical records will increase the faithfullnes of the contents in them and it will contribute to construct the good health information system. Method : From Jan. 1st. 2001 to March 31st 2001, we gathered as many paper clinical sheets as possible by every class of institutions to review the faithfulness of the clinical contents in them. Clinical sheets of 9 tertiary care hospitals, 6 general hospitals and 56 clinics were gathered. Two experienced medical record administrators reviewed them. The review focus was to check whether the items recommend by the hospital standardization review criteria and hospital service evaluation organization were appeared in the clinical sheets and whether the contents of every item were written. Results : Tertiary care hospitals; In case of administrative data, the contents were filled well if the items were fixed. The clinical data like C.C, history,physical examiniation were filled well, but if the items were not fixed, some items were omitted. The result is that more items are to be filled if they are fixed. General hospitals Administrative data were filled more than 50%. Final diagnosis was filled about 66.7%.But other clinical data were not filled well and not many clinical related items were appeared in the sheets.In the legal point of view, the reason for visiting hosptals or the right diagnosis, patient condition at discharge could not be confirmed well.In surgery cases, surgical procedures could not be confirmed well as many surgical related information(surgery time, fluids and blood, number of sponges, biopsy, etc) were omitted. Clinics More than 70% administrative data were filled and fixed as items. Among the clinical related data, laboratory result was the most credible data. But without the right diagnosis, drug orders were given and doctors' written signatures were not appeared over 96.4%. So the clinical sheets cannot be used as a legal document. Conculusion : There was a tendency that the contents were filled well if the items were fixed in the documents, We also suggest a clinical check list to review the completeness and faithfulness of the clinical sheets. If many hospitals use the suggested clincal check list and if they make the necessary items fixed in the clinical sheets, the quality of the medical record will increase dramatically.

  • PDF